Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis

被引:4
|
作者
Freitas, Anderson [1 ,2 ]
Barin, Fabricio Reichert [1 ]
Battaglion, Leonardo Rigobello [2 ]
da Costa, Helio Ismael [1 ]
Santos, Eduardo Duarte [1 ]
Rosado, Hugo Amando [1 ]
Giordano, Marcos [3 ]
Giordano, Vincenzo [4 ]
Shimano, Antonio Carlos [2 ]
机构
[1] IPE HOME Inst Pesquisa & Ensino Hosp Ortoped & Me, Res & Educ Inst, Orthoped & Specialized Med Hosp, SGAS Quadra 613 Conjunto C, BR-70200730 Brasilia, DF, Brazil
[2] Sao Paulo Univ FMRP USP, Dept Orthoped & Anesthesiol, Sao Paulo, Brazil
[3] Galeao Area Force Hosp HFAG, Rio De Janeiro, Brazil
[4] Nova Monteiro Miguel Couto Municipal Hosp, Orthoped & Traumatol Serv, Rio De Janeiro, Brazil
关键词
Femoral neck fracture; Internal fixation; Intramedullary fixation; Finite-element analysis; CANNULATED SCREW; INTRAMEDULLARY; PLATE;
D O I
10.1007/s43465-021-00420-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To evaluate the biomechanical behavior of a metaphyseal stem specifically designed for the fixation of Pauwels type-III femoral neck fractures using finite-element analysis. Methods Three different constructions were studied: the dynamic hip screw with a superior anti-rotation screw (DHS + ARS), multiple cannulated screws in an inverted triangle configuration (ASNIS), and the Metaphyseal Nailing System (MNS), a new implant developed by the authors. Vertical and total displacement, localized and total maximum and minimum principal, and the Von Mises peak stresses were evaluated. Results Results are shown for the DHS + ARS, ASNIS, and MNS models, respectively. Vertical displacement (mm) was 1.49, 3.63, and 1.90; total displacement (mm) was: 5.33, 6.02, and 6.30; localized maximum principal (Mpa) was: 2.77, 4.5, and 1.7; Total maximum principal (Mpa) was: 126, 223, and 531; localized minimum principal (Mpa) was: -1.8, -3.15, and -0.39; total minimum (Mpa) was: -121, -449, and -245; and Von Mises peak stress (MPA) was: 315.5, 326.1, and 286.0. Conclusion The present FEM study showed that the MNS device increases general stresses and reduces localized stresses, when compared to the DHS + ARS and ASNIS constructions used to fix Pauwels type-III femoral neck fracture in synthetic models. In this sense, the MNS showed a low fracture focus shift, conducive to the consolidation environment. The significant reduction in the maximum principal stress, allows to affirm that the main deforming force, the shear, in this fracture pattern, was considerably reduced and the low value of Von Mises obtained, consistent with an implant capable of making an effective load sharing.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 50 条
  • [41] Choose the appropriate implantation position of the Femoral Neck System in the femoral neck: a finite-element analysis
    Ximu Kuang
    Guojian Jian
    Desheng Xie
    Xiaolin Chen
    Haoyuan Liu
    European Journal of Trauma and Emergency Surgery, 2023, 49 : 1845 - 1853
  • [42] RETRACTION: The Effect on the Fracture Healing following Femoral Neck Shortening after Osteoporotic Femoral Neck Fracture Treated with Internal Fixation: Finite Element Analysis
    Yu, X.
    Rong, P. -z.
    Pang, Q. -j
    Chen, X. -j.
    Shi, L.
    Wang, C. -h.
    BIOMED RESEARCH INTERNATIONAL, 2024, 2024
  • [43] Choose the appropriate implantation position of the Femoral Neck System in the femoral neck: a finite-element analysis
    Kuang, Ximu
    Jian, Guojian
    Xie, Desheng
    Chen, Xiaolin
    Liu, Haoyuan
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2023, 49 (04) : 1845 - 1853
  • [44] Predicting femoral neck fracture using finite element analysis
    Testi, D
    Viceconti, M
    Cappello, A
    Gnudi, S
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 9 - 14
  • [45] Biomechanical comparison of Gofried positive support reduction of Pauwels type III femoral neck fractures: A finite elements analysis
    Ding, Ming
    Su, Zhihao
    Wang, Daoyu
    Mo, Lan
    Mei, Jiong
    Sun, Wanju
    Li, Shuang
    Ni, Ming
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (12):
  • [46] Finite element analysis of the effect of cannulated screw placement and drilling frequency on femoral neck fracture fixation
    Mei, Jiong
    Liu, Shiwei
    Jia, Guangyao
    Cui, Xueliang
    Jiang, Chao
    Ou, Yi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (12): : 2045 - 2050
  • [47] Comparison of three different internal fixation implants in treatment of femoral neck fracture—a finite element analysis
    Jia Li
    Zhe Zhao
    Pengbin Yin
    Licheng Zhang
    Peifu Tang
    Journal of Orthopaedic Surgery and Research, 14
  • [48] Biomechanical effect of different femoral neck blade position on the fixation of intertrochanteric fracture: a finite element analysis
    Lee, Pei-Yuan
    Lin, Kun-Jhih
    Wei, Hung-Wen
    Hu, Jin-Jia
    Chen, Wen-Chuan
    Tsai, Cheng-Lun
    Lin, Kang-Ping
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2016, 61 (03): : 331 - 336
  • [49] Analysis on risk factors for neck shortening after internal fixation for Pauwels II femoral neck fracture in young patients
    Fulong Zhao
    Lijuan Guo
    Xuefei Wang
    Yakui Zhang
    European Journal of Medical Research, 26
  • [50] Analysis on risk factors for neck shortening after internal fixation for Pauwels II femoral neck fracture in young patients
    Zhao, Fulong
    Guo, Lijuan
    Wang, Xuefei
    Zhang, Yakui
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2021, 26 (01)