Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis

被引:4
|
作者
Freitas, Anderson [1 ,2 ]
Barin, Fabricio Reichert [1 ]
Battaglion, Leonardo Rigobello [2 ]
da Costa, Helio Ismael [1 ]
Santos, Eduardo Duarte [1 ]
Rosado, Hugo Amando [1 ]
Giordano, Marcos [3 ]
Giordano, Vincenzo [4 ]
Shimano, Antonio Carlos [2 ]
机构
[1] IPE HOME Inst Pesquisa & Ensino Hosp Ortoped & Me, Res & Educ Inst, Orthoped & Specialized Med Hosp, SGAS Quadra 613 Conjunto C, BR-70200730 Brasilia, DF, Brazil
[2] Sao Paulo Univ FMRP USP, Dept Orthoped & Anesthesiol, Sao Paulo, Brazil
[3] Galeao Area Force Hosp HFAG, Rio De Janeiro, Brazil
[4] Nova Monteiro Miguel Couto Municipal Hosp, Orthoped & Traumatol Serv, Rio De Janeiro, Brazil
关键词
Femoral neck fracture; Internal fixation; Intramedullary fixation; Finite-element analysis; CANNULATED SCREW; INTRAMEDULLARY; PLATE;
D O I
10.1007/s43465-021-00420-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To evaluate the biomechanical behavior of a metaphyseal stem specifically designed for the fixation of Pauwels type-III femoral neck fractures using finite-element analysis. Methods Three different constructions were studied: the dynamic hip screw with a superior anti-rotation screw (DHS + ARS), multiple cannulated screws in an inverted triangle configuration (ASNIS), and the Metaphyseal Nailing System (MNS), a new implant developed by the authors. Vertical and total displacement, localized and total maximum and minimum principal, and the Von Mises peak stresses were evaluated. Results Results are shown for the DHS + ARS, ASNIS, and MNS models, respectively. Vertical displacement (mm) was 1.49, 3.63, and 1.90; total displacement (mm) was: 5.33, 6.02, and 6.30; localized maximum principal (Mpa) was: 2.77, 4.5, and 1.7; Total maximum principal (Mpa) was: 126, 223, and 531; localized minimum principal (Mpa) was: -1.8, -3.15, and -0.39; total minimum (Mpa) was: -121, -449, and -245; and Von Mises peak stress (MPA) was: 315.5, 326.1, and 286.0. Conclusion The present FEM study showed that the MNS device increases general stresses and reduces localized stresses, when compared to the DHS + ARS and ASNIS constructions used to fix Pauwels type-III femoral neck fracture in synthetic models. In this sense, the MNS showed a low fracture focus shift, conducive to the consolidation environment. The significant reduction in the maximum principal stress, allows to affirm that the main deforming force, the shear, in this fracture pattern, was considerably reduced and the low value of Von Mises obtained, consistent with an implant capable of making an effective load sharing.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 50 条
  • [21] Comparative finite element analysis of four different internal fixation implants for Pauwels type III femoral neck fractures in various fracture angles in the sagittal plane
    Ozer, Alaettin
    Oner, Kerim
    Okutan, Ahmet Emin
    Ayas, Muhammet Salih
    JOINT DISEASES AND RELATED SURGERY, 2022, 33 (02): : 352 - 358
  • [22] Stability of femoral neck fracture fixation: A finite element analysis
    Samsami, Shabnam
    Augat, Peter
    Rouhi, Gholamreza
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (09) : 892 - 900
  • [23] Evaluation of full thread screw and different fixation configurations in Pauwels type III femoral neck fracture
    Qiu, Jianjun
    Zou, Hanlin
    Zhang, Lei
    Zhou, Xu
    HELIYON, 2023, 9 (11)
  • [24] Biomechanical analysis for five fixation techniques of Pauwels-III fracture by finite element modeling
    Peng, Matthew Jian-Qiao
    Xu, HongWen
    Chen, Hai-Yan
    Lin, Ze
    Li, XinXu
    Shen, ChuLong
    Lau, YongQiang
    He, ErXing
    Guo, YueMing
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 193
  • [25] Medial femoral plate with cannulated screw for Pauwels type III femoral neck fracture: A meta-analysis
    Su, Zhengbing
    Liang, Linlin
    Hao, Yong
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2021, 34 (02) : 169 - 177
  • [26] Finite element analysis of fixation effect for femoral neck fracture under different fixation configurations
    Cui, Haipo
    Wei, Wenqing
    Shao, Yinlin
    Du, Kewei
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (02) : 132 - 139
  • [27] FINITE-ELEMENT ANALYSIS OF A FRACTURE FIXATION SYSTEM
    HULSE, D
    AUER, J
    NELSON, J
    VETERINARY SURGERY, 1987, 16 (01) : 93 - 93
  • [28] Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis
    Zhong, Zhou
    Lan, Xuejun
    Xiang, Zhou
    Duan, Xin
    CLINICAL BIOMECHANICS, 2023, 108
  • [29] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Gao, Zhichao
    Wang, Mei
    Shen, Baojie
    Chu, Xiaodong
    Ruan, Di
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [30] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Zhichao Gao
    Mei Wang
    Baojie Shen
    Xiaodong Chu
    Di Ruan
    Scientific Reports, 11