Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis

被引:4
|
作者
Freitas, Anderson [1 ,2 ]
Barin, Fabricio Reichert [1 ]
Battaglion, Leonardo Rigobello [2 ]
da Costa, Helio Ismael [1 ]
Santos, Eduardo Duarte [1 ]
Rosado, Hugo Amando [1 ]
Giordano, Marcos [3 ]
Giordano, Vincenzo [4 ]
Shimano, Antonio Carlos [2 ]
机构
[1] IPE HOME Inst Pesquisa & Ensino Hosp Ortoped & Me, Res & Educ Inst, Orthoped & Specialized Med Hosp, SGAS Quadra 613 Conjunto C, BR-70200730 Brasilia, DF, Brazil
[2] Sao Paulo Univ FMRP USP, Dept Orthoped & Anesthesiol, Sao Paulo, Brazil
[3] Galeao Area Force Hosp HFAG, Rio De Janeiro, Brazil
[4] Nova Monteiro Miguel Couto Municipal Hosp, Orthoped & Traumatol Serv, Rio De Janeiro, Brazil
关键词
Femoral neck fracture; Internal fixation; Intramedullary fixation; Finite-element analysis; CANNULATED SCREW; INTRAMEDULLARY; PLATE;
D O I
10.1007/s43465-021-00420-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To evaluate the biomechanical behavior of a metaphyseal stem specifically designed for the fixation of Pauwels type-III femoral neck fractures using finite-element analysis. Methods Three different constructions were studied: the dynamic hip screw with a superior anti-rotation screw (DHS + ARS), multiple cannulated screws in an inverted triangle configuration (ASNIS), and the Metaphyseal Nailing System (MNS), a new implant developed by the authors. Vertical and total displacement, localized and total maximum and minimum principal, and the Von Mises peak stresses were evaluated. Results Results are shown for the DHS + ARS, ASNIS, and MNS models, respectively. Vertical displacement (mm) was 1.49, 3.63, and 1.90; total displacement (mm) was: 5.33, 6.02, and 6.30; localized maximum principal (Mpa) was: 2.77, 4.5, and 1.7; Total maximum principal (Mpa) was: 126, 223, and 531; localized minimum principal (Mpa) was: -1.8, -3.15, and -0.39; total minimum (Mpa) was: -121, -449, and -245; and Von Mises peak stress (MPA) was: 315.5, 326.1, and 286.0. Conclusion The present FEM study showed that the MNS device increases general stresses and reduces localized stresses, when compared to the DHS + ARS and ASNIS constructions used to fix Pauwels type-III femoral neck fracture in synthetic models. In this sense, the MNS showed a low fracture focus shift, conducive to the consolidation environment. The significant reduction in the maximum principal stress, allows to affirm that the main deforming force, the shear, in this fracture pattern, was considerably reduced and the low value of Von Mises obtained, consistent with an implant capable of making an effective load sharing.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 50 条
  • [1] Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis
    Anderson Freitas
    Fabrício Reichert Barin
    Leonardo Rigobello Battaglion
    Hélio Ismael da Costa
    Eduardo Duarte Santos
    Hugo Amando Rosado
    Marcos Giordano
    Vincenzo Giordano
    Antonio Carlos Shimano
    Indian Journal of Orthopaedics, 2021, 55 : 378 - 384
  • [2] Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture
    Teng, Yanbin
    Zhang, Yan
    Guo, Chaowei
    MEDICINE, 2022, 101 (28) : E29450
  • [3] Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture
    Lin Tianye
    Yang Peng
    Xu Jingli
    Wei QiuShi
    Zhou GuangQuan
    He Wei
    Zhang Qingwen
    BIOMEDICINE & PHARMACOTHERAPY, 2019, 112
  • [4] Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis
    Yonghan Cha
    Jun Young Chung
    Chang-Ho Jung
    Jin-Woo Kim
    Jeyoon Lee
    Jun-Il Yoo
    Jung-Taek Kim
    Yongho Jeon
    BMC Musculoskeletal Disorders, 24
  • [5] Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis
    Cha, Yonghan
    Chung, Jun Young
    Jung, Chang-Ho
    Kim, Jin-Woo
    Lee, Jeyoon
    Yoo, Jun-Il
    Kim, Jung-Taek
    Jeon, Yongho
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [6] Finite element analysis of a new plate for Pauwels type III femoral neck fractures
    Wang, Gang
    Tang, Yong
    Wu, Xuhua
    Yang, Huilin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (02)
  • [7] Finite element analysis of the Femoral neck system for different placement positions in the fixation of Pauwels type III femoral neck fractures
    Zhu, Yongjia
    Wu, Shuai
    Yan, Jiapeng
    Wang, Wenhong
    Huang, Xiao
    Zhang, Hongfei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (04):
  • [8] Biomechanical evaluation of different internal fixation methods based on finite element analysis for Pauwels type III femoral neck fracture
    Jiang, Xianbao
    Liang, Ke
    Du, Gang
    Chen, Yuan
    Tang, Yu
    Geng, Kuihua
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10): : 3115 - 3123
  • [9] Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture A FINITE ELEMENT ANALYSIS
    Jung, C-H
    Cha, Y.
    Yoon, H. S.
    Park, C. H.
    Yoo, J-, I
    Kim, J-T
    Jeon, Y.
    BONE & JOINT RESEARCH, 2022, 11 (02): : 102 - 111
  • [10] Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis
    Lin, Shiyuan
    Shang, Jie
    Xing, Baizhou
    Wu, Biao
    Peng, Rong
    Wang, Gang
    Lu, Hua-Ding
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)