Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320-Detector Row Volume Scanner

被引:132
|
作者
Einstein, Andrew J. [1 ,2 ]
Elliston, Carl D. [3 ]
Arai, Andrew E. [4 ]
Chen, Marcus Y. [4 ]
Mather, Richard [5 ]
Pearson, Gregory D. N. [2 ]
DeLaPaz, Robert L. [2 ]
Nickoloff, Edward [2 ]
Dutta, Ajoy [2 ]
Brenner, David J. [3 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10032 USA
[2] Columbia Univ, Med Ctr, Dept Radiol, New York, NY 10032 USA
[3] Columbia Univ, Med Ctr, Ctr Radiol Res, New York, NY 10032 USA
[4] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[5] Toshiba Amer Med Syst, Tustin, CA USA
基金
美国国家卫生研究院;
关键词
CARDIAC COMPUTED-TOMOGRAPHY; ARTERY-DISEASE; LENGTH PRODUCT; IMAGE QUALITY; DIAGNOSIS;
D O I
10.1148/radiol.09090779
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine radiation doses from coronary computed tomographic (CT) angiography performed by using a 320-detector row volume scanner and evaluate how the effective dose depends on scan mode and the calculation method used. Materials and Methods: Radiation doses from coronary CT angiography performed by using a volume scanner were determined by using metaloxide-semiconductor field-effect transistor detectors positioned in an anthropomorphic phantom physically and radiographically simulating a male or female human. Organ and effective doses were determined for six scan modes, including both 64-row helical and 280-row volume scans. Effective doses were compared with estimates based on the method most commonly used in clinical literature: multiplying dose-length product (DLP) by a general conversion coefficient (0.017 or 0.014 mSv . mGy(-1) . cm(-1)), determined from Monte Carlo simulations of chest CT by using single-section scanners and previous tissue-weighting factors. Results: Effective dose was reduced by up to 91% with volume scanning relative to helical scanning, with similar image noise. Effective dose, determined by using International Commission on Radiological Protection publication 103 tissue-weighting factors, was 8.2 mSv, using volume scanning with exposure permitting a wide reconstruction window, 5.8 mSv with optimized exposure and 4.4 mSv for optimized 100-kVp scanning. Estimating effective dose with a chest conversion coefficient resulted in a dose as low as 1.8 mSv, substantially underestimating effective dose for both volume and helical coronary CT angiography. Conclusion: Volume scanning markedly decreases coronary CT angiography radiation doses compared with those at helical scanning. When conversion coefficients are used to estimate effective dose from DLP, they should be appropriate for the scanner and scan mode used and reflect current tissue-weighting factors. (C) RSNA, 2010.
引用
收藏
页码:698 / 706
页数:9
相关论文
共 50 条
  • [41] Fully Automated 3D-Coronary Endothelial Shear Stress Based on 320-Detector Row CT Angiography
    Rybicki, F.
    Mitsouras, D.
    Nallamshetty, L.
    Coskun, A.
    Feldman, C.
    Stone, P.
    Steigner, M.
    Chatzizisis, Y.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [42] Cerebral Aneurysms: Accuracy of 320-Detector Row Nonsubtracted and Subtracted Volumetric CT Angiography for Diagnosis
    Chen, Wenhua
    Xing, Wei
    Peng, Ya
    He, Zhongming
    Wang, Caoye
    Wang, Qi
    RADIOLOGY, 2013, 269 (03) : 841 - 849
  • [43] A Monte Carlo simulation for the estimation of patient dose in rest and stress cardiac computed tomography with a 320-detector row CT scanner
    Geleijns, Jacob
    Joemai, Raoul M. S.
    Cros, Maria
    Hernandez-Giron, Irene
    Calzado, Alfonso
    Dewey, Marc
    Salvado, Marcal
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1029 - 1034
  • [44] Diagnostic value of four-dimensional CT angiography in arterial erectile dysfunction using 320-detector row dynamic volume CT
    Xu, Cheng-Cheng
    Ruan, Xin-Zhong
    Tang, Yi-Fan
    Pan, Jiao-Hai
    Wang, Guo-Yao
    Huang, Qiu-Li
    BIOSCIENCE REPORTS, 2017, 37
  • [45] Quantification of coronary flow using dynamic angiography with 320-detector row CT: A new method for detecting ischemia for intermediate coronary stenosis
    Bai Mingjun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C38 - C38
  • [46] Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
    Yoneyama, Kihei
    Vavere, Andrea L.
    Cerci, Rodrigo
    Ahmed, Rukhsar
    Arai, Andrew E.
    Niinuma, Hiroyuki
    Rybicki, Frank J.
    Rochitte, Carlos E.
    Clouse, Melvin E.
    George, Richard T.
    Lima, Joao A. C.
    Arbab-Zadeh, Armin
    HEART INTERNATIONAL, 2012, 7 (02): : 51 - 56
  • [47] 320-Detector row CT angiography for detection and evaluation of intracranial aneurysms: Comparison with conventional digital subtraction angiography
    Wang, H.
    Li, W.
    He, H.
    Luo, L.
    Chen, C.
    Guo, Y.
    CLINICAL RADIOLOGY, 2013, 68 (01) : E15 - E20
  • [48] Initial evaluation of coronary images from 320-detector row computed tomography
    Frank J. Rybicki
    Hansel J. Otero
    Michael L. Steigner
    Gabriel Vorobiof
    Leelakrishna Nallamshetty
    Dimitrios Mitsouras
    Hale Ersoy
    Richard T. Mather
    Philip F. Judy
    Tianxi Cai
    Karl Coyner
    Kurt Schultz
    Amanda G. Whitmore
    Marcelo F. Di Carli
    The International Journal of Cardiovascular Imaging, 2008, 24 : 535 - 546
  • [49] Initial evaluation of coronary images from 320-detector row computed tomography
    Rybicki, Frank J.
    Otero, Hansel J.
    Steigner, Michael L.
    Vorobiof, Gabriel
    Nallamshetty, Leelakrishna
    Mitsouras, Dimitrios
    Ersoy, Hale
    Mather, Richard T.
    Judy, Philip F.
    Cai, Tianxi
    Coyner, Karl
    Schultz, Kurt
    Whitmore, Amanda G.
    Di Carli, Marcelo F.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (05): : 535 - 546
  • [50] Improved image quality of tube phantom simulating a coronary artery by averaging repeated scans using a 320-detector row CT scanner
    Fukuoka, Hidehiko
    Suzuki, Shogo
    Kono, Yasuhisa
    Shiotani, Seiji
    Kobayashi, Tomoya
    FORENSIC IMAGING, 2021, 24