Pleth Variability Index Predicts Fluid Responsiveness in Mechanically Ventilated Adults During General Anesthesia for Noncardiac Surgery

被引:28
|
作者
Siswojo, Andy Sisnata [1 ]
Wong, Daniel Mun-Yen [2 ]
Tuong Dien Phan [2 ]
Kluger, Roman [2 ]
机构
[1] Box Hill Hosp, Dept Anaesthesia, Box Hill, Vic 3128, Australia
[2] St Vincents Hosp, Fitzroy, Vic 3065, Australia
关键词
Pleth variability index; stroke volume; fluid responsiveness; hemodynamic monitoring; pulse oximeter; esophageal Doppler monitoring; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; CENTRAL VENOUS-PRESSURE; OF-THE-LITERATURE; CARDIAC-OUTPUT; HOSPITAL STAY; ESOPHAGEAL DOPPLER; PULSE OXIMETER; TRANSESOPHAGEAL DOPPLER; VOLUME;
D O I
10.1053/j.jvca.2014.04.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate whether the pleth variability index (PVI), derived noninvasively from a pulse oximeter probe, would predict fluid responsiveness in patients undergoing noncardiac surgeries. Design: A clinical, prospective, observational study. Setting: Operating room of a tertiary care hospital. Participants: Twenty-nine adult patients undergoing a range of noncardiac surgeries, requiring general anesthesia, tracheal intubation, and mechanical ventilation. Interventions: Intravenous volume expansion with 500 mL of colloid following induction of general anesthesia and after a period of hemodynamic stability before the start of surgery. Measurements and Main Results: Baseline values for PVI and stroke volume index, derived from an esophageal Doppler monitor, were compared with final values after the volume expansion. Patients were classified into fluid responders and nonresponders based on a stroke volume index increase of >= 10%. The optimal cut-off value for baseline pleth variability index for predicting fluid responsiveness was determined. There were 17 responders (59%) to the 500-mL volume expansion. Baseline PVI value was significantly different between responders and nonresponders (16.5 +/- 6.4% v 10.3 +/- 2.7%; p = 0.004). Receiver operating characteristic analysis demonstrated significant predictive ability of an increase in stroke volume index for PVI with area under the curve of 0.84 (95% confidence interval = 0.69-0.99). The optimal cut-off value for baseline PVI was 10.5%, with a sensitivity of 88% and a specificity of 67%. Conclusions: Pleth variability index is predictive of fluid responsiveness in adult patients undergoing noncardiac surgery. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [21] The Pleth Variability Index as a Guide to Fluid Therapy in Dogs Undergoing General Anesthesia: A Preliminary Study
    Vicenti, Caterina
    Romagnoli, Noemi
    Stabile, Marzia
    Lambertini, Carlotta
    Piemontese, Claudia
    Spaccini, Francesca
    Foglia, Armando
    Lacitignola, Luca
    Crovace, Antonio
    Staffieri, Francesco
    VETERINARY SCIENCES, 2024, 11 (09)
  • [22] Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index
    Broch, O.
    Bein, B.
    Gruenewald, M.
    Hoecker, J.
    Schoettler, J.
    Meybohm, P.
    Steinfath, M.
    Renner, J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (06) : 686 - 693
  • [23] Prediction of Fluid Responsiveness by the Effect of the Lung Recruitment Maneuver on the Perfusion Index in Mechanically Ventilated Patients During Surgery
    Morakul, Sunthiti
    Prachanpanich, Naruemol
    Permsakmesub, Pattarada
    Pinsem, Pimwatana
    Mongkolpun, Wasineenart
    Trongtrakul, Konlawij
    FRONTIERS IN MEDICINE, 2022, 9
  • [24] Study of 2 indexes Change in Pulsed Pressure and Pleth Variability Index for the assessment of fluid responsiveness during major abdominal surgery
    Jeantrelle, C.
    Josserand, J.
    Restoux, A.
    Gloulou, F.
    Abback, P. S.
    Angemont, B.
    Paugam, C.
    Fischler, M.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2014, 33 : A210 - A211
  • [25] Does the pleth variability index improve fluid management during major abdominal surgery?
    P Forget
    F Lois
    M De Kock
    Critical Care, 13 (Suppl 1):
  • [26] Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine
    Monnet, X.
    Guerin, L.
    Jozwiak, M.
    Bataille, A.
    Julien, F.
    Richard, C.
    Teboul, J.-L.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (02) : 207 - 213
  • [27] Agreement between Pleth Variability Index and oesophageal Doppler to predict fluid responsiveness
    Bahlmann, H.
    Hahn, R. G.
    Nilsson, L.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2016, 60 (02) : 183 - 192
  • [28] Does the plethysmographic variability index predict fluid responsiveness in mechanically ventilated children? A meta-analysis
    Desgranges, F. -P.
    Evain, J. -N.
    Neto, E. Pereira de Souza
    Raphael, D.
    Desebbe, O.
    Chassard, D.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (03) : 409 - 410
  • [29] Plethysmography variability index for prediction of fluid responsiveness during graded haemorrhage and transfusion in sevoflurane-anaesthetized mechanically ventilated dogs
    Endo, Yusuke
    Kawase, Koudai
    Miyasho, Taku
    Sano, Tadashi
    Yamashita, Kazuto
    Muir, William W.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (06) : 1303 - 1312
  • [30] THE PLETH VARIABILITY INDEX IS A WEAK PREDICTOR OF FLUID RESPONSIVENESS IN PATIENTS RECEIVING NOREPINEPHRINE
    Monnet, X.
    Guerin, L.
    Jozwiak, M.
    Bataille, A.
    Julien, F.
    Richard, C.
    Teboul, J-L
    INTENSIVE CARE MEDICINE, 2012, 38 : S269 - S270