Pleth Variability Index Predicts Fluid Responsiveness in Mechanically Ventilated Adults During General Anesthesia for Noncardiac Surgery

被引:28
|
作者
Siswojo, Andy Sisnata [1 ]
Wong, Daniel Mun-Yen [2 ]
Tuong Dien Phan [2 ]
Kluger, Roman [2 ]
机构
[1] Box Hill Hosp, Dept Anaesthesia, Box Hill, Vic 3128, Australia
[2] St Vincents Hosp, Fitzroy, Vic 3065, Australia
关键词
Pleth variability index; stroke volume; fluid responsiveness; hemodynamic monitoring; pulse oximeter; esophageal Doppler monitoring; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; CENTRAL VENOUS-PRESSURE; OF-THE-LITERATURE; CARDIAC-OUTPUT; HOSPITAL STAY; ESOPHAGEAL DOPPLER; PULSE OXIMETER; TRANSESOPHAGEAL DOPPLER; VOLUME;
D O I
10.1053/j.jvca.2014.04.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate whether the pleth variability index (PVI), derived noninvasively from a pulse oximeter probe, would predict fluid responsiveness in patients undergoing noncardiac surgeries. Design: A clinical, prospective, observational study. Setting: Operating room of a tertiary care hospital. Participants: Twenty-nine adult patients undergoing a range of noncardiac surgeries, requiring general anesthesia, tracheal intubation, and mechanical ventilation. Interventions: Intravenous volume expansion with 500 mL of colloid following induction of general anesthesia and after a period of hemodynamic stability before the start of surgery. Measurements and Main Results: Baseline values for PVI and stroke volume index, derived from an esophageal Doppler monitor, were compared with final values after the volume expansion. Patients were classified into fluid responders and nonresponders based on a stroke volume index increase of >= 10%. The optimal cut-off value for baseline pleth variability index for predicting fluid responsiveness was determined. There were 17 responders (59%) to the 500-mL volume expansion. Baseline PVI value was significantly different between responders and nonresponders (16.5 +/- 6.4% v 10.3 +/- 2.7%; p = 0.004). Receiver operating characteristic analysis demonstrated significant predictive ability of an increase in stroke volume index for PVI with area under the curve of 0.84 (95% confidence interval = 0.69-0.99). The optimal cut-off value for baseline PVI was 10.5%, with a sensitivity of 88% and a specificity of 67%. Conclusions: Pleth variability index is predictive of fluid responsiveness in adult patients undergoing noncardiac surgery. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [41] "Goal directed fluid management" based on pleth variability index or pulse pressure variations during abdominal surgery
    Delaporte, A.
    Ghoundiwal, D.
    Bidgoli, J.
    Foulon, P.
    Vanderlinden, P.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 59 - 59
  • [42] Pleth variability index as a tool for volume optimization during open abdominal surgery
    Bahlmann, H.
    Hahn, R.
    Nilsson, L.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 44 - 44
  • [43] Evaluation of fluid responsiveness with dynamic superior vena cava collapsibility index in mechanically ventilated patients
    Yaru Li
    Luyang Jiang
    Lu Wang
    Dou Dou
    Yi Feng
    Perioperative Medicine, 12
  • [44] Evaluation of fluid responsiveness with dynamic superior vena cava collapsibility index in mechanically ventilated patients
    Li, Yaru
    Jiang, Luyang
    Wang, Lu
    Dou, Dou
    Feng, Yi
    PERIOPERATIVE MEDICINE, 2023, 12 (01)
  • [45] Pleth variability index during preoxygenation did not reliably predict anesthesia-induced hypotension
    Crystal, George J.
    Pagel, Paul S.
    Salem, M. Ramez
    JOURNAL OF CLINICAL ANESTHESIA, 2024, 93
  • [46] Relationship between Pleth Variability Index and the Occurrence of Hypotension during Epidural Anesthesia for Cesarean Section
    Zang, Honggang
    Zhu, Lei
    Yan, Wenjun
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2021, 31 (06): : 619 - 622
  • [47] Change of QT variability index during general anesthesia
    Huh, In Young
    Kim, Dae-Young
    Sung, Minha
    Lee, Minhyun
    Park, Soon Eun
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2016, 69 (03) : 250 - 254
  • [48] Prediction of volume responsiveness using pleth variability index in patients undergoing cardiac surgery after cardiopulmonary bypass
    Haas, Sebastian
    Trepte, Constantin
    Hinteregger, Martin
    Fahje, Rebecca
    Sill, Bjoern
    Herich, Lena
    Reuter, Daniel A.
    JOURNAL OF ANESTHESIA, 2012, 26 (05) : 696 - 701
  • [49] The effects of pneumoperitoneum and patient position on the perfusion index and pleth variability index during laparoscopic bariatric surgery
    Arslantas, Reyhan
    Arslantas, Mustafa Kemal
    Tore Altun, Gulbin
    Corman Dincer, Pelin
    MARMARA MEDICAL JOURNAL, 2020, 33 (02): : 54 - 60
  • [50] Prediction of volume responsiveness using pleth variability index in patients undergoing cardiac surgery after cardiopulmonary bypass
    Sebastian Haas
    Constantin Trepte
    Martin Hinteregger
    Rebecca Fahje
    Bjoern Sill
    Lena Herich
    Daniel A. Reuter
    Journal of Anesthesia, 2012, 26 : 696 - 701