Pleth Variability Index Predicts Fluid Responsiveness in Mechanically Ventilated Adults During General Anesthesia for Noncardiac Surgery

被引:28
|
作者
Siswojo, Andy Sisnata [1 ]
Wong, Daniel Mun-Yen [2 ]
Tuong Dien Phan [2 ]
Kluger, Roman [2 ]
机构
[1] Box Hill Hosp, Dept Anaesthesia, Box Hill, Vic 3128, Australia
[2] St Vincents Hosp, Fitzroy, Vic 3065, Australia
关键词
Pleth variability index; stroke volume; fluid responsiveness; hemodynamic monitoring; pulse oximeter; esophageal Doppler monitoring; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; CENTRAL VENOUS-PRESSURE; OF-THE-LITERATURE; CARDIAC-OUTPUT; HOSPITAL STAY; ESOPHAGEAL DOPPLER; PULSE OXIMETER; TRANSESOPHAGEAL DOPPLER; VOLUME;
D O I
10.1053/j.jvca.2014.04.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate whether the pleth variability index (PVI), derived noninvasively from a pulse oximeter probe, would predict fluid responsiveness in patients undergoing noncardiac surgeries. Design: A clinical, prospective, observational study. Setting: Operating room of a tertiary care hospital. Participants: Twenty-nine adult patients undergoing a range of noncardiac surgeries, requiring general anesthesia, tracheal intubation, and mechanical ventilation. Interventions: Intravenous volume expansion with 500 mL of colloid following induction of general anesthesia and after a period of hemodynamic stability before the start of surgery. Measurements and Main Results: Baseline values for PVI and stroke volume index, derived from an esophageal Doppler monitor, were compared with final values after the volume expansion. Patients were classified into fluid responders and nonresponders based on a stroke volume index increase of >= 10%. The optimal cut-off value for baseline pleth variability index for predicting fluid responsiveness was determined. There were 17 responders (59%) to the 500-mL volume expansion. Baseline PVI value was significantly different between responders and nonresponders (16.5 +/- 6.4% v 10.3 +/- 2.7%; p = 0.004). Receiver operating characteristic analysis demonstrated significant predictive ability of an increase in stroke volume index for PVI with area under the curve of 0.84 (95% confidence interval = 0.69-0.99). The optimal cut-off value for baseline PVI was 10.5%, with a sensitivity of 88% and a specificity of 67%. Conclusions: Pleth variability index is predictive of fluid responsiveness in adult patients undergoing noncardiac surgery. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [1] Comparison of Rainbow Pleth Variability Index and Pleth Variability Index in mechanically ventilated patients under general anaesthesia
    Berger, Simon
    Poignant, Elizabeth
    Jacquet-Lagreze, Matthias
    Fellahi, Jean-Luc
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2021, 40 (01)
  • [2] Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery
    Zimmermann, Markus
    Feibicke, Thomas
    Keyl, Cornelius
    Prasser, Christopher
    Moritz, Stefan
    Graf, Bernhard M.
    Wiesenack, Christoph
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (06) : 555 - 561
  • [3] Pleth Variability Index to Predict Fluid Responsiveness in Colorectal Surgery
    Hood, Julian A.
    Wilson, R. Jonathan T.
    ANESTHESIA AND ANALGESIA, 2011, 113 (05): : 1058 - 1063
  • [4] Pleth Variability Index predicts fluid responsiveness in critically ill patients
    H Nanadoumgar
    TL Loupec
    DF Frasca
    FP Petitpas
    LL Laksiri
    DB Baudouin
    OM Mimoz
    Critical Care, 15 (Suppl 1):
  • [5] Pleth variability index predicts fluid responsiveness in critically ill patients
    Loupec, Thibault
    Nanadoumgar, Hodanou
    Frasca, Denis
    Petitpas, Franck
    Laksiri, Leila
    Baudouin, Didier
    Debaene, Bertrand
    Dahyot-Fizelier, Claire
    Mimoz, Olivier
    CRITICAL CARE MEDICINE, 2011, 39 (02) : 294 - 299
  • [6] Pleth variability index predicts hypotension during anesthesia induction
    Tsuchiya, M.
    Yamada, T.
    Asada, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (05) : 596 - 602
  • [7] Accuracy of pleth variability index compared with inferior vena cava diameter to predict fluid responsiveness in mechanically ventilated patients
    Piskin, Ozcan
    Oz, Ibrahim Ilker
    MEDICINE, 2017, 96 (47)
  • [8] Accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis
    Chu, Haitao
    Wang, Yong
    Sun, Yanfei
    Wang, Gang
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (03) : 265 - 274
  • [9] Accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis
    Haitao Chu
    Yong Wang
    Yanfei Sun
    Gang Wang
    Journal of Clinical Monitoring and Computing, 2016, 30 : 265 - 274
  • [10] Evaluation of pulse pressure variation and pleth variability index to predict fluid responsiveness in mechanically ventilated isoflurane-anesthetized dogs
    Sano, Hiroki
    Seo, Joonbum
    Wightman, Paul
    Cave, Nick J.
    Gieseg, Mike A.
    Johnson, Craig B.
    Chambers, Paul
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2018, 28 (04) : 301 - 309