Haemodynamic effects of stent diameter and compaction ratio on flow-diversion treatment of intracranial aneurysms: A numerical study of a successful and an unsuccessful case

被引:28
|
作者
Zhang, Mingzi [1 ,2 ]
Li, Yujie [1 ,2 ]
Zhao, Xi [1 ]
Verrelli, David I. [1 ]
Chong, Winston [3 ,4 ]
Ohta, Makoto [5 ]
Qian, Yi [1 ]
机构
[1] Macquarie Univ, Fac Med & Hlth Sci, Dept Biomed Sci, 2 Technol Pl, Sydney, NSW 2109, Australia
[2] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi, Japan
[3] Monash Med Ctr, Neuroradiol Dept, Melbourne, Vic, Australia
[4] Monash Univ, Sch Clin Sci, Dept Surg, Fac Med Nursing & Hlth Sci, Clayton, Vic, Australia
[5] Tohoku Univ, Inst Fluid Sci, Sendai, Miyagi, Japan
基金
澳大利亚研究理事会;
关键词
Computational fluid dynamics; Intracranial aneurysm; Flow-diverting stent; Device diameter; Compaction ratio; COMPUTATIONAL HEMODYNAMICS; CEREBRAL ANEURYSMS; DIVERTOR STENT; IN-SILICO; DEPLOYMENT; DEVICE; CFD;
D O I
10.1016/j.jbiomech.2017.05.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: Compacting a flow-diverting (FD) stent is an emerging technique to create a denser configuration of wires across the aneurysm ostium. However, quantitative analyses of post-stenting haemodynamics affected by the compaction level of different stent sizes remain inconclusive. Objective: To compare the aneurysmal haemodynamic alterations after virtual FD treatments with different device diameters at different compaction ratios. Methods: We virtually implanted three sizes of FD stent, with each size deployed at four compaction ratios, into two patient aneurysms previously treated with the Silk + FD-one successful case and the other unsuccessful. Wire configurations of the FD in the 24 treatment scenarios were examined, and aneurysmal haemodynamic alterations were resolved by computational fluid dynamics (CFD) simulations. We investigated the aneurysmal flow patterns, aneurysmal average velocity (AAV), mass flowrate (MF), and energy loss (EL) in each scenario. Results: Compactions of the stent in the successful case resulted in a greater metal coverage rate than that achieved in the unsuccessful one. A 25% increment in compaction ratio further decreased the AAV (12%), MF (11%), and EL (9%) in both cases (average values). The averaged maximum differences attributable to device size were 10% (AAV), 8% (MF), and 9% (EL). Conclusions: Both stent size and compaction level could markedly affect the FD treatment outcomes. It is therefore important to individualise the treatment plan by selecting the optimal stent size and deployment procedure. CFD simulation can be used to investigate the treatment outcomes, thereby assisting doctors in choosing a favourable treatment plan. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 39 条
  • [31] Flow diversion with hydrophilic polymer coating with prasugrel as single antiplatelet therapy in the treatment of acutely ruptured intracranial aneurysms: a multicenter case series, complication and occlusion rates
    Khanafer, Ali
    Lobsien, Donald
    Sirakov, Alexander
    Almohammad, Mohammad
    Schuengel, Marie-Sophie
    Pielenz, Daniel
    Borgmann, Thomas
    Hajiyev, Kamran
    Baezner, Hansjoerg
    Ganslandt, Oliver
    Hennersdorf, Florian
    Cohen, Jose E.
    Felber, Stephan
    Schob, Stefan
    Kemmling, Andre
    Sirakov, Stanimir
    Forsting, Michael
    Klisch, Joachim
    Henkes, Hans
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [32] Half-dose ticagrelor versus standard-dose clopidogrel in a dual antiplatelet regimen for stent-assisted coiling or flow diversion of unruptured intracranial aneurysms: a cohort study
    Li, Yi-Chen
    Yi, Man-Man
    Wang, Rong
    Xu, Man-Man
    Liu, Tao
    Na, Shi-Jie
    Shao, Teng-Fei
    Ding, Lan-Ping
    Ge, Wei-Hong
    Peng, Yu-Zhu
    Zhuang, Zong
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [33] European Multicenter Study for the Evaluation of a Dual-Layer Flow-Diverting Stent for Treatment of Wide-Neck Intracranial Aneurysms: The European Flow-Redirection Intraluminal Device Study
    Killer-Oberpfalzer, M.
    Kocer, N.
    Griessenauer, C. J.
    Janssen, H.
    Engelhorn, T.
    Holtmannspotter, M.
    Buhk, J. H.
    Finkenzeller, T.
    Fesl, G.
    Trenkler, J.
    Reith, W.
    Berlis, A.
    Hausegger, K.
    Augustin, M.
    Islak, C.
    Minnich, B.
    Moehlenbruch, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (05) : 841 - 847
  • [34] Treatment of unruptured intracranial vertebral artery dissection aneurysms with Flow Diverter compared with conventional stent-assisted coiling-a single-center study
    Zhang, Tongfu
    Zhong, Weiying
    Zhou, Donglin
    Xu, Yangyang
    Li, Maogui
    Zhuang, Jianfeng
    Wang, Donghai
    Su, Wandong
    Wang, Yunyan
    ACTA NEUROCHIRURGICA, 2024, 166 (01)
  • [35] Treatment of giant intracranial aneurysms using the Pipeline flow-diverting stent: Long-term results from the International Retrospective Study of the Pipeline Embolization Device (IntrePED) study
    Grandhi, Ramesh
    Ravindra, Vijay M.
    Kallmes, David F.
    Lopes, Demetrius
    Hanel, Ricardo A.
    Lylyk, Pedro
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (02) : 218 - 226
  • [36] Utility of P2Y12 Reactive Unit Assessment on Ticagrelor in Cerebral Aneurysms Treated with Intracranial Stenting and Flow Diversion: Cohort Study and Case Report From Two Neurovascular Centers
    Bohan, Christian O.
    Wirtz, Mirja M.
    Hendrix, Philipp
    Goren, Oded
    Schirmer, Clemens M.
    Islak, Civan
    Grassi, Dante M.
    Dalal, Shamsher
    Weiner, Gregory
    Griessenauer, Christoph J.
    WORLD NEUROSURGERY, 2020, 142 : E445 - E452
  • [37] A numerical study on the in-nozzle flow and near-field spray dynamics of spirally grooved hole nozzles: Effects of injection pressure and length/diameter ratio
    Leng, Xianyin
    Xing, Mochen
    Deng, Yicheng
    Jin, Yu
    He, Zhixia
    PHYSICS OF FLUIDS, 2024, 36 (11)
  • [38] Effects of Pulsatile Flow Rate and Shunt Ratio in Bifurcated Distal Arteries on Hemodynamic Characteristics Involved in Two Patient-Specific Internal Carotid Artery Sidewall Aneurysms: A Numerical Study
    Yi, Hang
    Johnson, Mark
    Bramlage, Luke C.
    Ludwig, Bryan
    Yang, Zifeng
    BIOENGINEERING-BASEL, 2022, 9 (07):
  • [39] Evaluating the safety and technical effectiveness of a newly developed intravascular 'flow isolator' stent for the treatment of intracranial aneurysms: study protocol for a first-in-human single-arm multiple-site clinical trial in Japan
    Yamamoto, Haruko
    Hamasaki, Toshimitsu
    Onda, Kaori
    Nakayama, Yasuhide
    Ishii, Akira
    Oishi, Hidenori
    Sakai, Nobuyuki
    Satow, Tetsu
    BMJ OPEN, 2019, 9 (05):