Haemodynamic effects of stent diameter and compaction ratio on flow-diversion treatment of intracranial aneurysms: A numerical study of a successful and an unsuccessful case

被引:28
|
作者
Zhang, Mingzi [1 ,2 ]
Li, Yujie [1 ,2 ]
Zhao, Xi [1 ]
Verrelli, David I. [1 ]
Chong, Winston [3 ,4 ]
Ohta, Makoto [5 ]
Qian, Yi [1 ]
机构
[1] Macquarie Univ, Fac Med & Hlth Sci, Dept Biomed Sci, 2 Technol Pl, Sydney, NSW 2109, Australia
[2] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi, Japan
[3] Monash Med Ctr, Neuroradiol Dept, Melbourne, Vic, Australia
[4] Monash Univ, Sch Clin Sci, Dept Surg, Fac Med Nursing & Hlth Sci, Clayton, Vic, Australia
[5] Tohoku Univ, Inst Fluid Sci, Sendai, Miyagi, Japan
基金
澳大利亚研究理事会;
关键词
Computational fluid dynamics; Intracranial aneurysm; Flow-diverting stent; Device diameter; Compaction ratio; COMPUTATIONAL HEMODYNAMICS; CEREBRAL ANEURYSMS; DIVERTOR STENT; IN-SILICO; DEPLOYMENT; DEVICE; CFD;
D O I
10.1016/j.jbiomech.2017.05.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: Compacting a flow-diverting (FD) stent is an emerging technique to create a denser configuration of wires across the aneurysm ostium. However, quantitative analyses of post-stenting haemodynamics affected by the compaction level of different stent sizes remain inconclusive. Objective: To compare the aneurysmal haemodynamic alterations after virtual FD treatments with different device diameters at different compaction ratios. Methods: We virtually implanted three sizes of FD stent, with each size deployed at four compaction ratios, into two patient aneurysms previously treated with the Silk + FD-one successful case and the other unsuccessful. Wire configurations of the FD in the 24 treatment scenarios were examined, and aneurysmal haemodynamic alterations were resolved by computational fluid dynamics (CFD) simulations. We investigated the aneurysmal flow patterns, aneurysmal average velocity (AAV), mass flowrate (MF), and energy loss (EL) in each scenario. Results: Compactions of the stent in the successful case resulted in a greater metal coverage rate than that achieved in the unsuccessful one. A 25% increment in compaction ratio further decreased the AAV (12%), MF (11%), and EL (9%) in both cases (average values). The averaged maximum differences attributable to device size were 10% (AAV), 8% (MF), and 9% (EL). Conclusions: Both stent size and compaction level could markedly affect the FD treatment outcomes. It is therefore important to individualise the treatment plan by selecting the optimal stent size and deployment procedure. CFD simulation can be used to investigate the treatment outcomes, thereby assisting doctors in choosing a favourable treatment plan. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 39 条
  • [21] Endovascular treatment of intracranial vertebral artery unruptured dissecting aneurysms: Comparison of flow diversion and stent-assisted coiling or stenting alone
    Li, Li
    Xu, Gang-Qin
    Gao, Hui-Li
    Gao, Bu-Lang
    Zhang, Kun
    Wang, Zi-Liang
    Li, Tian-Xiao
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [22] Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms COMMENT
    Nickele, Christopher
    Arthur, Adam S.
    NEUROSURGERY, 2016, 78 (06) : 867 - 867
  • [23] Endoluminal flow diversion as a primary treatment strategy for pediatric traumatic intracranial aneurysms: a case-based review of literature
    Hosseini, Ehsan Mohammad
    Zafarshamspour, Saber
    Ghasemi-Rad, Mohammad
    Benndorf, Goetz
    Rasekhi, Alireza
    Rafieossadat, Reza
    CHILDS NERVOUS SYSTEM, 2024, 40 (02) : 345 - 357
  • [24] Endoluminal flow diversion as a primary treatment strategy for pediatric traumatic intracranial aneurysms: a case-based review of literature
    Ehsan Mohammad Hosseini
    Saber Zafarshamspour
    Mohammad Ghasemi-Rad
    Goetz Benndorf
    Alireza Rasekhi
    Reza Rafieossadat
    Child's Nervous System, 2024, 40 : 345 - 357
  • [25] European multicenter study for evaluation of a dual layer flow diverting stent for treatment of wide neck intracranial aneurysms: the EuFRED study
    Griessenauer, Christoph Johannes
    Killer-Oberpfalzer, Monika
    Kocer, Naci
    Janssen, Hendrik
    Engelhorn, Tobias
    Holtmannspotter, Markus
    Buhk, Jahn
    Finkenzeller, Thomas
    Fesl, Gunther
    Trenkler, Johannes
    Reith, Wolfgang
    Mohlenbruch, Markus
    JOURNAL OF NEUROSURGERY, 2018, 128 (04) : 34 - 34
  • [26] Response to Letter Regarding Article "Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms: A Prospective Study in 29 Patients With 34 Aneurysms"
    Lubicz, Boris
    STROKE, 2011, 42 (03) : E40 - E40
  • [27] Letter by Pierot Regarding Article "Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms: A Prospective Study in 29 Patients With 34 Aneurysms"
    Pierot, Laurent
    STROKE, 2011, 42 (03) : E38 - E39
  • [28] Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study
    Berge, J.
    Biondi, A.
    Machi, P.
    Brunel, H.
    Pierot, L.
    Gabrillargues, J.
    Kadziolka, K.
    Barreau, X.
    Dousset, V.
    Bonafe, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1150 - 1155
  • [29] Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study
    Foa Torres, G.
    Roca, F.
    Noguera, A.
    Godes, J.
    Petrocelli, S.
    Aznar, I.
    Ales, S.
    Muszynski, P.
    Maehara, R.
    Vicente, M.
    Pumar, J. M.
    INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (04) : 357 - 362
  • [30] Low-profile visualized intraluminal support-within-Enterprise overlapping-stent technique versus flow diversion in the treatment of intracranial vertebrobasilar trunk dissecting aneurysms
    Wu, Qiaowei
    Wang, Chunlei
    Xu, Shancai
    Ji, Zhiyong
    Qi, Jingtao
    Li, Yuchen
    Yao, Jinbiao
    Shi, Huaizhang
    Wu, Pei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (06) : 3536 - 3546