New capabilities of the incoherent Thomson scattering diagnostics in the TCV tokamak: divertor and real-time measurements

被引:22
|
作者
Arnichand, H. [1 ]
Andrebe, Y. [1 ]
Blanchard, P. [1 ]
Antonioni, S. [1 ]
Couturier, S. [1 ]
Decker, J. [1 ]
Duval, B. P. [1 ]
Felici, F. [1 ]
Galperti, C. [1 ]
Isoz, P-F [1 ]
Lavanchy, P. [1 ]
Llobet, X. [1 ]
Marletaz, B. [1 ]
Marmillod, P. [1 ]
Masur, J. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, SPC, CH-1015 Lausanne, Switzerland
来源
基金
瑞士国家科学基金会;
关键词
Optics; Plasma diagnostics - charged-particle spectroscopy; Real-time monitoring; Spectrometers;
D O I
10.1088/1748-0221/14/09/C09013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work reports developments of the incoherent TS diagnostic capabilities in the Tokamak a Configuration Variable (TCV). Their goals are to (i) diagnose the TCV divertor region, and (ii) provide Te and ne profiles of the plasma bulk in real-time. These two new TS diagnostic capabilities are implemented within the framework of a TCV upgrade that will insert baffles in the lower divertor region. 20 new TS spectrometers are being installed to access electron temperatures down to similar to 1 eV, for densities above similar to 1.5 x 10(19) m(-3) within the TCV divertor region. They will measure the Thomson light scattered along the vertical propagation path of the three legacy Nd:YAG lasers. The light at each of the 20 measurement plasma volumes is collected by three optical fibers with a laser-mapped spatial resolution of 5-6 mm each, providing a vertical spatial resolution of 15-18mm. Interference filters with central. Interference filters with central wavelengths from 1025 to 1061 nm and widths as low as similar to 2 nm are employed to obtain the spectroscopic resolution required at these low temperatures. The acquisition chain and analysis of the TS signal will be integrated into the TCV monitoring and control system to provide electron density and temperature profiles in real-time, at a sampling rate up to 60 Hz. The real time electron property profiles complement existing systems provided by the far-infrared interferometer and the soft X-ray diagnostics. The latter are restricted to provide integrated values of the electron density and temperature respectively, but at higher sampling rates (10 kHz and 20 kHz respectively). The whole diagnostic ensemble will be integrated into TCV's control system to improve the accuracy and robustness of real-time plasma profile and equilibrium estimation for control purposes.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A multi-channel real-time digital integrator for magnetic diagnostics in HL-2A tokamak
    Chen, Chao
    Fan, Wei-Wei
    Pan, Yin-Hai
    Ji, Xiao-Quan
    Yin, Ze-Jie
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (01)
  • [32] A multi-channel real-time digital integrator for magnetic diagnostics in HL-2A tokamak
    Chao Chen
    Wei-Wei Fan
    Yin-Hai Pan
    Xiao-Quan Ji
    Ze-Jie Yin
    NuclearScienceandTechniques, 2016, 27 (01) : 85 - 90
  • [33] Real-time radiative divertor feedback control development for the NSTX-U tokamak using a vacuum ultraviolet spectrometer
    Soukhanovskii, V. A.
    Kaita, R.
    Stratton, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [34] Thomson scattering measurements on DIII-D using in-vessel laser mirrors and lenses to diagnose a new divertor location
    Carlstrom, T. N.
    Glass, F.
    Du, D.
    McLean, A. G.
    Taussig, D.
    Boivin, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [35] A new solution of real-time electromagnetic inverse-scattering
    Zhang Qing-He
    Xiao Bo-Xun
    Zhu Guo-Qiang
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2006, 49 (05): : 1546 - 1551
  • [36] Application of virtual machine technology to real-time mapping of Thomson scattering data to flux coordinates for the LHD
    Emoto, Masahiko
    Yoshida, Masanobu
    Suzuki, Chihiro
    Suzuki, Yasuhiro
    Ida, Katsumi
    Nagayama, Yoshio
    Akiyama, Tsuyoshi
    Kawahata, Kazuo
    Narihara, Kazumichi
    Tokuzawa, Tokihiko
    Yamada, Ichihiro
    FUSION ENGINEERING AND DESIGN, 2012, 87 (12) : 2076 - 2080
  • [37] PHOTOINDUCED ANISOTROPY - NEW PHOTOPOLARIMETRIC SETUP FOR REAL-TIME MEASUREMENTS
    NIKOLOVA, L
    TODOROV, T
    SHARLANDJIEV, P
    STOYANOV, S
    APPLIED OPTICS, 1992, 31 (31): : 6698 - 6701
  • [38] Spectroscopic light scattering for real-time measurements of thin film and surface evolution
    Chason, E
    Sinclair, MB
    Floro, JA
    Hunter, JA
    Hwang, RQ
    APPLIED PHYSICS LETTERS, 1998, 72 (25) : 3276 - 3278
  • [39] Adding Indoor Location Capabilities to an IEEE 802.11 WLAN using Real-Time RTT Measurements
    Prieto, J.
    Bahillo, A.
    Mazuelas, S.
    Lorenzo, R. M.
    Blas, J.
    Fernandez, P.
    WTS: 2009 WIRELESS TELECOMMUNICATIONS SYMPOSIUM, 2009, : 113 - +
  • [40] Time-stretched spectrally encoded angular light scattering for high-throughput real-time diagnostics
    Adam, Jost
    Mahjoubfar, Ata
    Diebold, Eric D.
    Buckley, Brandon W.
    Jalali, Bahram
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE IV, 2014, 9129