New capabilities of the incoherent Thomson scattering diagnostics in the TCV tokamak: divertor and real-time measurements

被引:22
|
作者
Arnichand, H. [1 ]
Andrebe, Y. [1 ]
Blanchard, P. [1 ]
Antonioni, S. [1 ]
Couturier, S. [1 ]
Decker, J. [1 ]
Duval, B. P. [1 ]
Felici, F. [1 ]
Galperti, C. [1 ]
Isoz, P-F [1 ]
Lavanchy, P. [1 ]
Llobet, X. [1 ]
Marletaz, B. [1 ]
Marmillod, P. [1 ]
Masur, J. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, SPC, CH-1015 Lausanne, Switzerland
来源
基金
瑞士国家科学基金会;
关键词
Optics; Plasma diagnostics - charged-particle spectroscopy; Real-time monitoring; Spectrometers;
D O I
10.1088/1748-0221/14/09/C09013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work reports developments of the incoherent TS diagnostic capabilities in the Tokamak a Configuration Variable (TCV). Their goals are to (i) diagnose the TCV divertor region, and (ii) provide Te and ne profiles of the plasma bulk in real-time. These two new TS diagnostic capabilities are implemented within the framework of a TCV upgrade that will insert baffles in the lower divertor region. 20 new TS spectrometers are being installed to access electron temperatures down to similar to 1 eV, for densities above similar to 1.5 x 10(19) m(-3) within the TCV divertor region. They will measure the Thomson light scattered along the vertical propagation path of the three legacy Nd:YAG lasers. The light at each of the 20 measurement plasma volumes is collected by three optical fibers with a laser-mapped spatial resolution of 5-6 mm each, providing a vertical spatial resolution of 15-18mm. Interference filters with central. Interference filters with central wavelengths from 1025 to 1061 nm and widths as low as similar to 2 nm are employed to obtain the spectroscopic resolution required at these low temperatures. The acquisition chain and analysis of the TS signal will be integrated into the TCV monitoring and control system to provide electron density and temperature profiles in real-time, at a sampling rate up to 60 Hz. The real time electron property profiles complement existing systems provided by the far-infrared interferometer and the soft X-ray diagnostics. The latter are restricted to provide integrated values of the electron density and temperature respectively, but at higher sampling rates (10 kHz and 20 kHz respectively). The whole diagnostic ensemble will be integrated into TCV's control system to improve the accuracy and robustness of real-time plasma profile and equilibrium estimation for control purposes.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Real-time estimation and control of divertor surface heat flux on the DIII-D tokamak
    Anand, H.
    Eldon, D.
    Humphreys, D.
    Hyatt, A.
    Sammuli, B.
    Welander, A.
    Barr, J.
    Scotti, F.
    Boedo, J.
    Fusion Engineering and Design, 2021, 171
  • [22] Real-time estimation and control of divertor surface heat flux on the DIII-D tokamak
    Anand, H.
    Eldon, D.
    Humphreys, D.
    Hyatt, A.
    Sammuli, B.
    Welander, A.
    Barr, J.
    Scotti, F.
    Boedo, J.
    FUSION ENGINEERING AND DESIGN, 2021, 171
  • [23] Feedback system for divertor impurity seeding based on real-time measurements of surface heat flux in the Alcator C-Mod tokamak
    Brunner, D.
    Burke, W.
    Kuang, A. Q.
    LaBombard, B.
    Lipschultz, B.
    Wolfe, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [24] Integration of a Real-Time Node for Magnetic Perturbations Signal Analysis in the Distributed Digital Control System of the TCV Tokamak
    Galperti, C.
    Coda, S.
    Duval, B. P.
    Llobet, X.
    Milne, P.
    Sauter, O.
    Moret, J. M.
    Testa, D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (06) : 1446 - 1454
  • [25] Development of Real-Time Software for Thomson Scattering Analysis at NSTX-U
    Rozenblat, Roman
    Kolemen, Egemen
    Laggner, Florian M.
    Freeman, Christopher
    Tchilinguirian, Greg
    Sichta, Paul
    Zimmer, Gretchen
    FUSION SCIENCE AND TECHNOLOGY, 2019, 75 (08) : 835 - 840
  • [26] New Opportunities in Real-Time Diagnostics of Induction Machines
    Baraskova, Tatjana
    Kudelina, Karolina
    Shirokova, Veroonika
    ENERGIES, 2024, 17 (13)
  • [27] A scalable real-time framework for Thomson scattering analysis: Application to NSTX-U
    Laggner, F. M.
    Diallo, A.
    LeBlanc, B. P.
    Rozenblat, R.
    Tchilinguirian, G.
    Kolemen, E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (04):
  • [28] Real-Time Ethernet Interface for NSTX-U's Thomson Scattering Diagnostic (2023)
    Trieu, S.
    Hoffmann, F.
    de Haas, M.
    Tchilinguirian, G.
    Leblanc, B. P.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (06) : 2213 - 2217
  • [29] A multi-channel real-time digital integrator for magnetic diagnostics in HL-2A tokamak
    Chao Chen
    Wei-Wei Fan
    Yin-Hai Pan
    Xiao-Quan Ji
    Ze-Jie Yin
    Nuclear Science and Techniques, 2016, 27
  • [30] Real-time acquisition and remote monitoring of steady state tokamak (SST-1) diagnostics data
    Dey, Manika
    Pujara, H. D.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) : 1198 - 1202