Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves

被引:223
|
作者
Flameng, Willem [1 ]
Herregods, Marie-Christine [2 ]
Vercalsteren, Monique [1 ]
Herijgers, Paul [1 ]
Bogaerts, Kris [3 ]
Meuris, Bart [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Div Cardiac Surg, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Dis, Dept Cardiol, Leuven, Belgium
[3] Univ Hasselt, Ctr Biostat, Diepenbeek, Belgium
关键词
bioprosthesis; prosthesis-patient mismatch; surgery; valves; LONG-TERM SURVIVAL; AORTIC-VALVE; REPLACEMENT; POSITION; STENTLESS; IMPACT; DETERIORATION; RISK; CALCIFICATION; REOPERATION;
D O I
10.1161/CIRCULATIONAHA.109.901272
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. Methods and Results-In 564 patients (mean age, 74+/-5 years) receiving an aortic valve bioprosthesis, clinical follow-up (median, 6.1 years; maximum, 16.4 years) was analyzed including echocardiography. SVD was diagnosed in 40 patients (7%) as substantially increased stenosis (n=24) or regurgitation (n=16) of the operated valve over time. When patients with P-PtM (effective orifice area index <0.85 cm(2)/m(2); n=285) developed SVD, it was preferentially of the stenosis type, whereas when patients without P-PtM (n=279) developed SVD, the majority was of the incompetence type (P<0.05). Multivariable analysis including patient-and valve-related variables revealed that P-PtM and label size <= 21 were independent predictors of SVD (P=0.04 and P=0.02, respectively). A nonparametric Turnbull estimate analysis showed that SVD is virtually nonexistent for up to 9 years in patients without P-PtM. Thereafter, SVD starts to occur and is mainly of the incompetence-type SVD (79% of cases). In patients with P-PtM, SVD starts to occur after 2 to 3 years after implantation and is mainly of the stenosis-type SVD (81% of cases). Conclusions-These data suggest that stenosis-type SVD is an early, P-PtM-related, and thus preventable phenomenon. Incompetence-type SVD is a time-dependent, nonspecific wear damage to bioprosthetic valves, which is not related to P-PtM. (Circulation. 2010; 121: 2123-2129.)
引用
收藏
页码:2123 / 2129
页数:7
相关论文
共 50 条
  • [1] Structural valve degeneration in bioprosthetic aortic valves is frequent and strongly related to prosthesis-patient mismatch
    Krenn, L.
    Fuchs, C.
    Binder, T.
    Kocher, A.
    Maurer, G.
    Mascherbauer, J.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1086 - 1087
  • [2] Type 2 diabetes and prosthesis-patient mismatch are associated with faster structural valve degeneration in bioprosthetic aortic valves
    Ruiz Bustillo, S.
    Perez, A. B.
    Ble Gimeno, M.
    Gomez Perez, M.
    Tizon Marcos, H.
    Molina Ferragut, L.
    Bruguera Cortada, J.
    Fernandez Gasalla, A.
    Bueno Lopez, D.
    Cladellas Capdevila, M.
    EUROPEAN HEART JOURNAL, 2015, 36 : 1158 - 1158
  • [3] Antimineralization treatment and patient-prosthesis mismatch are major determinants of the onset and incidence of structural valve degeneration in bioprosthetic heart valves
    Flameng, Willem
    Rega, Filip
    Vercalsteren, Monique
    Herijgers, Paul
    Meuris, Bart
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (04): : 1219 - 1224
  • [4] PROSTHESIS-PATIENT MISMATCH BETWEEN TRANSCATHETER HEART VALVES IN TRANSCATHETER AORTIC VALVE REPLACEMENT
    Sengupta, Aditya
    Zaid, Syed
    Storch, Jason
    Gupta, Eisha
    Hirji, Sameer
    Ahmad, Hasan
    Khan, Asaad
    Undemir, Cenap
    Ali, Omar
    Skiles, Jeffrey
    Goldberg, Joshua
    Lansman, Steven
    Kovacic, Jason
    Dangas, George D.
    Sharma, Samin K.
    Kini, Annapoorna Subhash
    Ramlawi, Basel
    Shah, Pinak
    Kaneko, Tsuyoshi
    Tang, Gilbert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1421 - 1421
  • [5] VALVE PROSTHESIS-PATIENT MISMATCH - REPLY
    RAHIMTOOLA, SS
    CIRCULATION, 1979, 59 (02) : 418 - 419
  • [6] Valve prosthesis-patient mismatch: An update
    Rahimtoola, SH
    JOURNAL OF HEART VALVE DISEASE, 1998, 7 (02): : 207 - 210
  • [7] The effect of prosthesis-patient mismatch on aortic bioprosthetic valve hemodynamic performance and patient clinical status
    Pibarot, P
    Honos, GN
    Durand, LG
    Dumesnil, JG
    CANADIAN JOURNAL OF CARDIOLOGY, 1996, 12 (04) : 379 - 387
  • [8] Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity and mortality after aortic valve replacement with a bioprosthetic heart valve
    Pibarot, P
    Dumesnil, JG
    Lemieux, M
    Cartier, P
    Metras, J
    Durand, LG
    JOURNAL OF HEART VALVE DISEASE, 1998, 7 (02): : 211 - 218
  • [9] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [10] Prosthesis-Patient Mismatch in Patients With Bicuspid Aortic Valve
    Messika-Zeitoun, David
    Burwash, Ian G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2025, 18 (04) : 503 - 505