Radiography of the distal interphalangeal joints of two limbs of a cadaver of a horse weighing 550 kg was conducted in the present study. The examination was performed on lateromedial, palmaroproximal-palmarodistal views and on dorsoproximal-palmarodistal, dorsolateral-palmaromedial, dorsomedial-palmarolateral views of a raised limb placed on a navicular block, and of weight-bearing limbs. During the examination, doses of scattered radiation were measured at the sites of radiographer, assistant holding a film cassette and assistant positioning the examined limb or the opposite one. The lowest radiation dose was received by the assistant holding the cassette behind the examined region; a total equivalent dose of 183.6 - 201.7 nSv was received by his hands and genitals, and 110.8 - 113.3 nSv by his eye tens and neck during the examination of the distal interphalangeal joint. The radiographer was exposed to higher radiation; an equivalent dose of 846.6 - 854.1 nSv was received by his hands and genitals, and 271.8 - 328.2 nSv by the eye lens and the neck. The highest scattered radiation dose was received by the assistant positioning the examined limbs; equivalent doses were 7751 - 9354 nSv (hands), 1117.3 - 1119.5 nSv (genitals), and 880.6 - 1096.2 nSv (eye lens and neck). The equivalent dose values measured, received by the radiographer and the assistants during the examination of the distal interphalangeal joint seem to be very low relative to radiation exposure limits. However, it must be taken into account that the personnel involved in radiography is also exposed to scattered radiation during other examinations where radiation doses are often much higher. These results indicate the necessity to use protective lead aprons, gloves and collars during radiography of the distal interphalangeal joint.
引用
收藏
页码:105 / +
页数:11
相关论文
共 50 条
  • [31] Radiation exposure of the patient during x-ray examination with the ProScan chest x-ray survey unit
    Gurzhiev A.N.
    Gurzhiev S.N.
    Korablev V.M.
    Kostritskii A.V.
    Alekseev A.G.
    Pikalov V.A.
    Biomedical Engineering, 2008, 42 (5) : 226 - 232
  • [33] Reprint of 'Evaluation of Scattered Radiation Emitted From X-ray Security Scanners on Occupational Dose to Airport Personnel'
    Dalah, Entesar
    Fakhry, Angham
    Mukhtar, Asma
    Al Salti, Farah
    Bader, May
    Khouri, Sara
    Al-Zahmi, Reem
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 103 - 106
  • [34] Immediate screening of lead exposure in the workplace using portable X-ray fluorescence
    Gorce, Jean-Philippe
    Roff, Martin
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2016, 13 (02) : 102 - 111
  • [35] Radiation load associated with target-oriented and panoramic X-ray examination using portable X-ray apparatuses
    Potrakhov N.N.
    Potrakhov E.N.
    Gryaznov A.Yu.
    Vorob'Ev B.F.
    Biomedical Engineering, 2008, 42 (6) : 312 - 313
  • [36] Radiation injury from x-ray exposure during brachytherapy localization
    Thomadsen, BR
    Paliwal, BR
    Petereit, DG
    Ranallo, FN
    MEDICAL PHYSICS, 2000, 27 (07) : 1681 - 1684
  • [37] Staff and patient exposure to X-ray radiation during cardiac procedures
    Jankowski, J.
    Papierz, S.
    Domienik, J.
    Kacprzyk, J.
    Tybor-Czerwinska, Maja
    Werduch, A.
    POLISH JOURNAL OF RADIOLOGY, 2008, 73 (01) : 40 - 43
  • [38] Scattering ray exposure of personnel during veterinary X-ray examinations with the C-bow-technique
    Nölker, A
    Ueltschi, G
    TIERARZTLICHE UMSCHAU, 2001, 56 (10): : 519 - +
  • [39] Evaluation of radiation exposure to operators of portable hand-held dental X-ray units
    Leadbeatter, Justin
    Diffey, Jennifer
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 377 - 385
  • [40] Evaluation of radiation exposure to operators of portable hand-held dental X-ray units
    Justin Leadbeatter
    Jennifer Diffey
    Physical and Engineering Sciences in Medicine, 2021, 44 : 377 - 385