Partial least-squares modeling of near-infrared reflectance data for noninvasive in vivo determination of deep-tissue pH

被引:44
|
作者
Zhang, SB
Soller, BR
Micheels, RH
机构
[1] Univ Massachusetts, Med Ctr, Dept Surg, Worcester, MA 01655 USA
[2] Polestar Technol Inc, Needham Hts, MA 02194 USA
关键词
pH; muscle; in vivo; near-infrared spectroscopy; multivariate calibration;
D O I
10.1366/0003702981943581
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Noninvasive monitoring of deep-tissue pH has been demonstrated with the use of near-infrared spectroscopic measurements and the partial least-squares (PLS) multivariate calibration technique. The near-infrared reflectance spectra (700 to 1100 nm) of the teres major muscle in five New Zealand rabbits were obtained in vivo, along with reference pH values in the muscle measured by microelectrodes, The muscle pH was varied by controlling the blood supply to the muscle, PLS analysis with cross-validation techniques, along with several data preprocessing methods, was used to relate the tissue pH to spectra, When multi-subject PLS calibration models were used to predict a new independent subject, a subject-dependent offset was observed, Several strategies for minimizing the subject-dependent offset were discussed. With a baseline subtraction procedure, the subject-dependent offset was minimized to less than 0.1 pH units while the average standard error of prediction (SEP) was close to 0.05 pH units. This result suggests that it is possible to build a single robust calibration model for all nea independent subjects. Tissue chemistry during ischemia (blood Bow reduction) is different from the chemistry of reperfusion (blood how restoration), and it was found that separate calibration models permit more accurate prediction of pH.
引用
收藏
页码:400 / 406
页数:7
相关论文
共 50 条
  • [1] Application of partial least-squares regression to near-infrared reflectance spectroscopic determination of shive content in flax
    Sohn, M
    Barton, FE
    Morrison, WH
    Archibald, DD
    [J]. APPLIED SPECTROSCOPY, 2003, 57 (05) : 551 - 556
  • [2] Near-infrared lanthanide nanoprobes for deep-tissue in vivo imaging
    Sun, Ling-Dong
    Wang, Ye-Fu
    Zhang, Pei-Zhi
    Yan, Chun-Hua
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [3] Determination of kavalactones in dried kava (Piper methysticum) powder using near-infrared reflectance spectroscopy and partial least-squares regression
    Gautz, Loren D.
    Kaufusi, Pakieli
    Jackson, Mel C.
    Bittenbender, Harry C.
    Tang, Chung-Shih
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (17) : 6147 - 6152
  • [4] Near-Infrared Spectroscopy and Partial Least-Squares Regression for Determination of Arachidonic Acid in Powdered Oil
    Yang, Meiyan
    Nie, Shaoping
    Li, Jing
    Xie, Mingyong
    Xiong, Hua
    Deng, Zeyuan
    Zheng, Weiwan
    Li, Lin
    Zhang, Xiaoming
    [J]. LIPIDS, 2010, 45 (06) : 559 - 565
  • [5] Determination of Tetracyclines by near-infrared (NIR) Spectroscopy and partial least-squares (PLS) regression method
    Szlyk, Edward
    Kowalczyk-Marzec, Agnieszka
    Koter, Izabela
    [J]. CHEMIA ANALITYCZNA, 2007, 52 (04): : 605 - 617
  • [7] Near-infrared spectra combined with partial least squares for pH determination of toothpaste of different brands
    Ni, Yong Nian
    Lin, Wei
    [J]. CHINESE CHEMICAL LETTERS, 2011, 22 (12) : 1473 - 1476
  • [8] Nanocrystals for Deep-Tissue In Vivo Luminescence Imaging in the Near-Infrared Region
    Yang, Yang
    Jiang, Qunying
    Zhang, Fan
    [J]. CHEMICAL REVIEWS, 2023, 124 (02) : 554 - 628
  • [9] POPULATION STRUCTURING OF NEAR-INFRARED SPECTRA AND MODIFIED PARTIAL LEAST-SQUARES REGRESSION
    SHENK, JS
    WESTERHAUS, MO
    [J]. CROP SCIENCE, 1991, 31 (06) : 1548 - 1555
  • [10] MIDINFRARED SPECTRA FROM NEAR-INFRARED SPECTRA USING PARTIAL LEAST-SQUARES
    LEW, R
    BALKE, ST
    [J]. APPLIED SPECTROSCOPY, 1993, 47 (11) : 1747 - 1750