Near-infrared spectra combined with partial least squares for pH determination of toothpaste of different brands

被引:0
|
作者
Yong Nian Ni~(a
机构
基金
中国国家自然科学基金;
关键词
Toothpaste; NIR spectroscopy; Partial least squares; Preprocessing; pH value;
D O I
暂无
中图分类号
TQ658.41 [];
学科分类号
0817 ;
摘要
Near-infrared spectroscopy(NIR),which is generally used for online monitoring of the food analysis and production process, was applied to determine the internal quality of toothpaste samples.It is acknowledged that the spectra can be significantly influenced by non-linearities introduced by light scatter,therefore,four data preprocessing methods,including off-set correction, 1st-derivative,standard normal variate(SNV) and multiplicative scatter correction(MSC),were employed before the date analysis. The multivariate calibration model of partial least squares(PLS) was established and then was used to predict the pH values of the toothpaste samples of different brand.The results showed that the spectral date processed by MSC was the best one for predicting the pH value of the toothpaste samples.
引用
收藏
页码:1473 / 1476
页数:4
相关论文
共 50 条
  • [1] Near-infrared spectra combined with partial least squares for pH determination of toothpaste of different brands
    Ni, Yong Nian
    Lin, Wei
    [J]. CHINESE CHEMICAL LETTERS, 2011, 22 (12) : 1473 - 1476
  • [2] Dual stacked partial least squares for analysis of near-infrared spectra
    Bi, Yiming
    Xie, Qiong
    Peng, Silong
    Tang, Liang
    Hu, Yong
    Tan, Jie
    Zhao, Yuhui
    Li, Changwen
    [J]. ANALYTICA CHIMICA ACTA, 2013, 792 : 19 - 27
  • [3] An improved ensemble partial least squares for analysis of near-infrared spectra
    Hu, Yong
    Peng, Silong
    Peng, Jiangtao
    Wei, Jiping
    [J]. TALANTA, 2012, 94 : 301 - 307
  • [4] MIDINFRARED SPECTRA FROM NEAR-INFRARED SPECTRA USING PARTIAL LEAST-SQUARES
    LEW, R
    BALKE, ST
    [J]. APPLIED SPECTROSCOPY, 1993, 47 (11) : 1747 - 1750
  • [5] Determination of glycated hemoglobin using near-infrared spectroscopy combined with equidistant combination partial least squares
    Han, Yun
    Chen, Jiemei
    Pan, Tao
    Liu, Guisong
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 145 : 84 - 92
  • [6] Correlation between near-infrared tissue spectra and pH, temperature, and blood flow using partial least squares
    Khan, T
    Soller, BR
    Zhang, SB
    [J]. BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS, 1999, 3595 : 116 - 121
  • [7] POPULATION STRUCTURING OF NEAR-INFRARED SPECTRA AND MODIFIED PARTIAL LEAST-SQUARES REGRESSION
    SHENK, JS
    WESTERHAUS, MO
    [J]. CROP SCIENCE, 1991, 31 (06) : 1548 - 1555
  • [8] Determination of nicotine in tobacco samples by near-infrared spectroscopy and boosting partial least squares
    Tan, Chao
    Wang, Jinyue
    Wu, Tong
    Qin, Xin
    Li, Menglong
    [J]. VIBRATIONAL SPECTROSCOPY, 2010, 54 (01) : 35 - 41
  • [9] Near-infrared spectra of serum albumin and γ-globulin and determination of their concentrations in phosphate buffer solutions by partial least squares regression
    Murayama, K
    Yamada, K
    Tsenkova, R
    Wang, Y
    Ozaki, Y
    [J]. VIBRATIONAL SPECTROSCOPY, 1998, 18 (01) : 33 - 40
  • [10] Assessment of partial least-squares calibration and wavelength selection for complex near-infrared spectra
    McShane, MJ
    Cote, GL
    Spiegelman, CH
    [J]. APPLIED SPECTROSCOPY, 1998, 52 (06) : 878 - 884