Detection of Power Transformer Fault Conditions using Optical Characteristics of Transformer Oil

被引:0
|
作者
Fauzi, Nur Afini [1 ]
Thiviyanathan, Vimal Angela [1 ]
Leong, Yang Sing [1 ]
Ker, Pin Jern [1 ]
Jamaludin, M. Z. [1 ]
Nomanbhay, Saiffuddin M. [1 ]
Looe, H. M. [2 ]
Lo, C. K. [2 ]
机构
[1] Univ Tenaga Nas, Photon Technol Res Grp, Inst Power Engn, Jalan IKRAM UNITEN, Kajang 43000, Selangor, Malaysia
[2] TNB Res Sdn Bhd, Jalan Ayer Itam, Kajang 43000, Selangor, Malaysia
关键词
main transformer tank; On-load-tap-changer; spectrophotometer; transformer oil aging; DISSOLVED-GAS ANALYSIS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power transformers are important in the power transmission and distribution network. A continuous monitoring of the transformer is important in ensuring the prolonged service of the transformer. This paper focuses on the characterization of transformer oil using optical detection method. 10 Transformer oil samples from the main tanks and 11 oil samples from the on-load-tap-changer (OLTC) were obtained for the optical characterization from 200 to 3300 nm. Based on the conventional results interpretation using dissolved gas analysis (DGA) and Duval Triangle, the optical characteristics of the samples in 2120 to 2220 nm clearly demonstrate the detection of electrical discharges of high energy (D2), electrical discharges of low energy (D1) and thermal faults at temperatures above 700 degrees C (T3) faults. This approach provides a quicker and cheaper method to determine the condition of power transformers based on the optical characteristics of transformer oil.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Investigations of Transformer Oil Characteristics
    Karthik, R.
    Raja, T. Sree Renga
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2012, 7 (04) : 369 - 374
  • [32] Optical chemical sensor for oil-filled power transformer
    Cennamo, Nunzio
    Zeni, Luigi
    De Maria, Letizia
    D'Agostino, Girolamo
    Pesavento, Maria
    2014 FOTONICA AEIT ITALIAN CONFERENCE ON PHOTONICS TECHNOLOGIES, 2014,
  • [33] Fault Diagnosis for Oil Immersed Transformer Using Certainty Factor
    Kaur, Kulraj
    Bhalla, Deepika
    Singh, Jashandeep
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (01) : 485 - 494
  • [34] Optical characteristics of flashover in transformer oil under nanosecond pulses
    Huang, Wenli
    Liu, Shunxin
    Yan, Ping
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2009, 21 (05): : 787 - 790
  • [35] Pre-breakdown characteristics of contaminated power transformer oil
    Chen, G.
    Zuber, M. H.
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 659 - 662
  • [36] Dissolved Gas Analysis of Mineral Oil for Power Transformer Fault Diagnosis Using Fuzzy Logic
    Huang, Yann-Chang
    Sun, Huo-Ching
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (03) : 974 - 981
  • [37] Enhancement of Critical Characteristics of Transformer Oil Using Nanomaterials
    Karthik, R.
    Raja, T. Sree Renga
    Madavan, R.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2013, 38 (10) : 2725 - 2733
  • [38] Enhancement of Critical Characteristics of Transformer Oil Using Nanomaterials
    R. Karthik
    T. Sree Renga Raja
    R. Madavan
    Arabian Journal for Science and Engineering, 2013, 38 : 2725 - 2733
  • [39] Fault analysis of a main power transformer
    Zeng, Yi-Min
    He, Jin-Liang
    Gaoya Dianqi/High Voltage Apparatus, 2001, 37 (06):
  • [40] Research on Power Transformer Fault Forecast
    Zheng, RuiRui
    Zhao, JiYin
    Li, Min
    Wu, BaoChun
    ADVANCED RESEARCH ON INDUSTRY, INFORMATION SYSTEMS AND MATERIAL ENGINEERING, PTS 1-7, 2011, 204-210 : 1553 - 1558