Pre-breakdown characteristics of contaminated power transformer oil

被引:17
|
作者
Chen, G. [1 ]
Zuber, M. H. [1 ]
机构
[1] Univ Southampton, Southampton SO17 1BJ, Hants, England
关键词
D O I
10.1109/CEIDP.2007.4451551
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we have studied pre-breakdown characteristics of transformer oil in the presence of different levels of contamination. The contaminant is fibrous dust from pressboard insulation used for high voltage transformers. The contamination level investigated in the present study ranges from 0.0025 to 0.0075% by weight. The conduction current under dc voltages were recorded and bridging effect was monitored using optical images. It has been found that the conduction current typically increases with the applied voltage, the duration of the voltage application and the level of contamination. Optical images revealed that bridging occurs when oil is subjected to the voltage and bridge dimension increases with the contamination level and the duration. The current flowing between the two spherical electrodes is closely related to the bridging dynamics.
引用
收藏
页码:659 / 662
页数:4
相关论文
共 50 条
  • [1] OPTICAL OBSERVATION OF PRE-BREAKDOWN AND BREAKDOWN PHENOMENA IN TRANSFORMER OIL
    YAMASHITA, H
    AMANO, H
    MORI, T
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1977, 10 (13) : 1753 - &
  • [2] Pre-Breakdown Characteristics in Transformer Oil under Bipolar Oscillating Impulse Voltage
    Ding, Can
    Tu, Tiancheng
    Fang, Chunhua
    Yuan, Fating
    Li, Chengxi
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 4493 - 4496
  • [3] PRE-BREAKDOWN CURRENT AND LIGHT EMISSION IN TRANSFORMER OIL.
    Yamashita, H.
    Amano, H.
    1600, (EI-20):
  • [4] Effect of Floating Metallic Particles in Pre-Breakdown and Breakdown Characteristics of Oil Transformer under DC Voltage
    Negara, I. Made Yulistya
    Fahmi, Daniar
    Asfani, Dimas Anton
    Hernanda, I. Gusti Ngurah Satriyadi
    Wahyudi, Mochammad
    Ibrahim, Muhammad Novis
    ENERGIES, 2021, 14 (12)
  • [5] PRE-BREAKDOWN CURRENT AND LIGHT-EMISSION IN TRANSFORMER OIL
    YAMASHITA, H
    AMANO, H
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1985, 20 (02): : 247 - 255
  • [6] Pre-Breakdown Current Discrimination Diagnose Technique for Transformer Mineral Oil
    Moulai, H.
    Aberkane, F.
    Benyahia, F.
    Nacer, A.
    Beroual, A.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 412 - 415
  • [7] Pre-breakdown current discrimination diagnose technique for transformer mineral oil
    Benyahia, F.
    Moulai, H.
    Nacer, A.
    Aberkane, F.
    Beroual, A.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2013, 15 (11-12): : 1311 - 1315
  • [8] BREAKDOWN TIME LAGS AND PRE-BREAKDOWN PHENOMENA IN TRANSFORMER OIL, EFFECTS OF HYDROSTATIC-PRESSURE
    HIZAL, EM
    DINCER, S
    JOURNAL OF ELECTROSTATICS, 1982, 12 (APR) : 333 - 343
  • [9] PRE-BREAKDOWN PHENOMENA BETWEEN SPHERE-SPHERE ELECTRODES IN TRANSFORMER OIL
    KELLEY, EF
    HEBNER, RE
    APPLIED PHYSICS LETTERS, 1981, 38 (04) : 231 - 233
  • [10] TRANSIENT-BEHAVIOR IN TRANSFORMER OILS - PRE-BREAKDOWN AND BREAKDOWN PHENOMENA
    RZAD, SJ
    DEVINS, JC
    SCHWABE, RJ
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1979, 14 (06): : 289 - 296