Pre-breakdown characteristics of contaminated power transformer oil

被引:17
|
作者
Chen, G. [1 ]
Zuber, M. H. [1 ]
机构
[1] Univ Southampton, Southampton SO17 1BJ, Hants, England
关键词
D O I
10.1109/CEIDP.2007.4451551
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we have studied pre-breakdown characteristics of transformer oil in the presence of different levels of contamination. The contaminant is fibrous dust from pressboard insulation used for high voltage transformers. The contamination level investigated in the present study ranges from 0.0025 to 0.0075% by weight. The conduction current under dc voltages were recorded and bridging effect was monitored using optical images. It has been found that the conduction current typically increases with the applied voltage, the duration of the voltage application and the level of contamination. Optical images revealed that bridging occurs when oil is subjected to the voltage and bridge dimension increases with the contamination level and the duration. The current flowing between the two spherical electrodes is closely related to the bridging dynamics.
引用
收藏
页码:659 / 662
页数:4
相关论文
共 50 条
  • [41] BREAKDOWN CHARACTERISTICS OF MOVING TRANSFORMER OIL.
    Ikeda, M.
    Teranishi, T.
    Honda, M.
    Yanari, T.
    Radiophysics and Quantum Electronics (English Translation of Izvestiya Vysshikh Uchebnykh Zavedenii, Radiofizika), 1980,
  • [42] PRE-BREAKDOWN ELECTRON-EMISSION
    LATHAM, RV
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1983, 18 (03): : 194 - 203
  • [43] Dielectric breakdown characteristics of clean transformer oil
    Fujii, H
    Kurita, H
    Hasegawa, T
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 45 - 48
  • [44] Characteristics of a Silicon Carbide Field Emission Array under Pre-Breakdown Conditions
    Morozov, V. A.
    Egorov, N. V.
    Trofimov, V. V.
    Nikiforov, K. A.
    Zakirov, I. I.
    Kats, V. M.
    Ilyin, V. A.
    Ivanov, A. S.
    TECHNICAL PHYSICS, 2024, 69 (07) : 2059 - 2065
  • [45] THERMAL ANODE INSTABILITY IN PRE-BREAKDOWN STAGE OF VACUUM BREAKDOWN
    NEVROVSKII, VA
    ZHURNAL TEKHNICHESKOI FIZIKI, 1978, 48 (11): : 2301 - 2308
  • [46] Lock-in thermography for the localization of pre-breakdown leakage current on power diodes
    Riccio, M.
    Irace, A.
    Breglio, G.
    PRIME: PROCEEDINGS OF THE CONFERENCE 2009 PHD RESEARCH IN MICROELECTRONICS AND ELECTRONICS, 2009, : 208 - 211
  • [47] PRE-BREAKDOWN LUMINESCENCE PULSES IN LIQUID DIELECTRICS
    GZOWSKI, O
    NATURE, 1966, 212 (5058) : 185 - &
  • [48] High Resolution Thermal Imaging of Pre-Breakdown in Power AlGaN/GaN MOSHEMTs
    Maize, Kerry
    Zhou, Hong
    Ye, Peide D.
    Shakouri, Ali
    2017 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM (IRPS), 2017,
  • [49] PRE-BREAKDOWN AND BREAKDOWN IN SULFUR-HEXAFLUORIDE - SEMIEMPIRICAL APPROACH
    MALLER, VN
    NAIDU, MS
    INDIAN JOURNAL OF TECHNOLOGY, 1977, 15 (03): : 110 - 113
  • [50] Femtosecond breakdown and pre-breakdown behavior in dielectric thin films
    Mero, M
    Liu, J
    Sabbah, AJ
    Zeller, J
    Rudolph, W
    Starke, K
    Ristau, D
    COMMERCIAL AND BIOMEDICAL APPLICATIONS OF ULTRAFAST LASERS IV, 2004, 5340 : 133 - 145