Pre-breakdown characteristics of contaminated power transformer oil

被引:17
|
作者
Chen, G. [1 ]
Zuber, M. H. [1 ]
机构
[1] Univ Southampton, Southampton SO17 1BJ, Hants, England
关键词
D O I
10.1109/CEIDP.2007.4451551
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we have studied pre-breakdown characteristics of transformer oil in the presence of different levels of contamination. The contaminant is fibrous dust from pressboard insulation used for high voltage transformers. The contamination level investigated in the present study ranges from 0.0025 to 0.0075% by weight. The conduction current under dc voltages were recorded and bridging effect was monitored using optical images. It has been found that the conduction current typically increases with the applied voltage, the duration of the voltage application and the level of contamination. Optical images revealed that bridging occurs when oil is subjected to the voltage and bridge dimension increases with the contamination level and the duration. The current flowing between the two spherical electrodes is closely related to the bridging dynamics.
引用
收藏
页码:659 / 662
页数:4
相关论文
共 50 条
  • [21] Evaluation of additives for pre-breakdown characteristics using divergent fields
    Ganga, S
    Dwarakanath, K
    Sridhar, S
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 351 - 353
  • [22] Measurement of the Pre-Breakdown Characteristics in Silicon Carbide Power Devices by the Use of Radioactive Gamma Sources
    Ciappa, Mauro
    Pocaterra, Marco
    2020 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM (IRPS), 2020,
  • [23] ELECTRICAL BREAKDOWN OF GASES - THE PRE-BREAKDOWN STAGE
    KUNHARDT, EE
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1980, 8 (03) : 130 - 138
  • [24] DC BREAKDOWN CHARACTERISTICS OF TRANSFORMER OIL
    MURANO, M
    MENJU, S
    OHSHIMA, I
    ELECTRICAL COMMUNICATION, 1973, 93 (02): : 84 - 89
  • [25] BREAKDOWN CHARACTERISTICS OF MOVING TRANSFORMER OIL
    IKEDA, M
    TERANISHI, T
    HONDA, M
    YANARI, T
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (02): : 921 - 928
  • [26] GLOWS AND PRE-BREAKDOWN PHENOMENA
    LUCAS, J
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1981, 128 (04): : 313 - 318
  • [27] ON THE NOISE OF PRE-BREAKDOWN CURRENT
    KAWAMURA, H
    ONUKI, M
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1951, 6 (04) : 283 - 284
  • [28] Pre-breakdown Current in Long Point-plane Transformer Oil Gaps with Insulating Barrier under AC Voltage
    Guerbas, F.
    Boubakeur, A.
    Beroual, A.
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 744 - 747
  • [29] DC pre-breakdown phenomena and breakdown characteristics in the presence of metallic particle in liquid nitrogen
    Kyushu Univ, Fukuoka, Japan
    IEEE Int Conf Conduct Breakdown Dielectr Liq ICDL, (457-461):
  • [30] DC pre-breakdown phenomena and breakdown characteristics in the presence of conducting particles in liquid nitrogen
    Hara, M
    Suehiro, J
    Maeda, H
    Nakashima, H
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (01) : 23 - 30