Comparison of the Performance of Mask Ventilation Between Face Masks With and Without Air Cushion

被引:2
|
作者
Tsukamoto, Masanori [1 ]
Taura, Shiori [2 ]
Hitosugi, Takashi [3 ]
Yokoyama, Takeshi [3 ]
机构
[1] Kyushu Univ Hosp, Dept Dent Anesthesiol, Fukuoka, Fukuoka, Japan
[2] Kyushu Univ, Grad Sch Dent Sci, Dept Dent Anesthesiol, Fukuoka, Fukuoka, Japan
[3] Kyushu Univ, Fac Dent Sci, Dept Dent Anesthesiol, Fukuoka, Fukuoka, Japan
关键词
BAG; PREDICTION;
D O I
10.1016/j.joms.2019.08.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Mask ventilation is a basic technique for induction of anesthesia. In head and neck surgery, we have encountered difficulty in ventilation owing to facial deformities. Recently, a new type of face mask without an air cushion, the QuadraLite face mask (Intersurgical, Berkshire, UK), was developed. The aim of this study was to compare the performance of cases with predicted difficult mask ventilation between the new type of face mask and a traditional face mask. Patients and Methods: This study was a crossover prospective study. The participants were patients (aged > 18 years) who underwent oral-maxillofacial surgery under general anesthesia. The risk factors for a difficult airway were assessed. Patients were divided into 3 risk groups: low risk, 0 or 1 risk factor for predicted difficult mask ventilation; medium risk, 2 or 3 risk factors; and high risk, 4 or more risk factors. An air cushion face mask (Koo Medical, Shanghai, China) and the QuadraLite face mask were applied in turn under the setting of pressure-controlled ventilation. The expiratory tidal volumes were compared between these face masks. Results: A total of 48 patients were included: 16 in the low-risk group, 16 in the medium-risk group, and 16 in the high-risk group. Higher expiratory tidal volumes were observed with the QuadraLite face mask than with the air cushion face mask, although the differences did not reach the statistically significant level: 574.3 +/- 62.7 mL versus 553.1 +/- 60.6 mL in the low-risk group (P = .44), 553.1 +/- 112.9 mL versus 536.4 +/- 114.2 mL in the medium-risk group (P = .38), and 560.0 +/- 98.6 mL versus 548.2 +/- 07.1 mL in the high-risk group (P = .22). In all cases, a sufficient ventilation volume was obtained by the QuadraLite face mask. Conclusions: The QuadraLite face mask is compact because there is no air cushion, and it can provide sufficient mask ventilation as well as a traditional face mask with an air cushion even in patients with a difficult airway. (C) 2019 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:2465.e1 / 2465.e5
页数:5
相关论文
共 50 条
  • [31] Influence of total face masks design and circuit on synchrony and performance during pressure support ventilation: A bench study
    Ferrone, Giuliano
    Spinazzola, Giorgia
    Costa, Roberta
    Piastra, Marco
    Maresca, Gianmarco
    Antonelli, Massimo
    Conti, Giorgio
    RESPIRATORY MEDICINE AND RESEARCH, 2022, 82
  • [32] Performance of a new "helmet" versus a standard face mask during non-invasive mechanical ventilation
    Chiumello, D
    Carlesso, E
    Cadisco, A
    Paganini, S
    Libassi, G
    Storelli, E
    Rocchi, G
    INTENSIVE CARE MEDICINE, 2002, 28 : S49 - S49
  • [33] Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study
    Viyuki Nakamura, Maria Aparecida
    Vieira Costa, Eduardo Leite
    Ribeiro Carvalho, Carlos Roberto
    Tucci, Vlauro Roberto
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2014, 40 (03) : 294 - 303
  • [34] Laparoscopic Gynecological Surgery with Spontaneous/Assisted Ventilation through Face Mask (without Endotracheal Intubation or Laryngeal Mask). How safe and ENicient Is It? Case series
    Borrero-Cortes, Crystian
    Pinzon-Lozano, Laura J.
    Morales Behaine, Juan Jose
    ANESTHESIA AND ANALGESIA, 2024, 139 (06): : 2027 - 2028
  • [35] Comparison of endtidal CO2 and arterial blood gas analysis in paediatric patients undergoing controlled ventilation with a laryngeal mask or a face mask
    Özlü, O
    Öcal, T
    PAEDIATRIC ANAESTHESIA, 1999, 9 (05): : 409 - 413
  • [36] Comparison of Comfort and Effectiveness of Total Face Mask and Oronasal Mask in Noninvasive Positive Pressure Ventilation in Patients with Acute Respiratory Failure: A Clinical Trial
    Sadeghi, Somayeh
    Fakharian, Atefeh
    Nasri, Peiman
    Kiani, Arda
    CANADIAN RESPIRATORY JOURNAL, 2017, 2017
  • [37] Comparison of the efficacy of high-flow nasal oxygenation and spontaneous breathing with face mask ventilation during panendoscopy
    Conti, Clement
    Mauvais, Olivier
    Samain, Emmanuel
    Tavernier, Laurent
    Floury, Sebastien Pili
    Besch, Guillaume
    Ferreira, David
    BRITISH JOURNAL OF ANAESTHESIA, 2023, 130 (06) : E474 - E476
  • [38] Comparison of mouth-to-mouth, mouth-to-mask and mouth-to-face-shield ventilation by lay persons
    Paal, Peter
    Falk, Markus
    Sumann, Guenther
    Demetz, Florian
    Beikircher, Werner
    Gruber, Elisabeth
    Ellerton, John
    Brugger, Hermann
    RESUSCITATION, 2006, 70 (01) : 117 - 123
  • [39] Comparison of the performance properties of spunlaid non-woven fabrics used as face mask
    Korkmaz, Gursel
    Kilinc, Mehmet
    Razak, Sevim Atmaca
    Ocak, Munevver
    Korkmaz, Selma
    Kut, Y. Dilek Toprakkaya
    JOURNAL OF THE TEXTILE INSTITUTE, 2023, 114 (02) : 250 - 256
  • [40] AN EXPERIMENTAL COMPARISON BETWEEN SEMI-ACTIVE AND PASSIVE SUSPENSIONS FOR AIR-CUSHION VEHICLES
    HROVAT, D
    MARGOLIS, DL
    INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 1981, 2 (03) : 308 - 321