Comparison of the Performance of Mask Ventilation Between Face Masks With and Without Air Cushion

被引:2
|
作者
Tsukamoto, Masanori [1 ]
Taura, Shiori [2 ]
Hitosugi, Takashi [3 ]
Yokoyama, Takeshi [3 ]
机构
[1] Kyushu Univ Hosp, Dept Dent Anesthesiol, Fukuoka, Fukuoka, Japan
[2] Kyushu Univ, Grad Sch Dent Sci, Dept Dent Anesthesiol, Fukuoka, Fukuoka, Japan
[3] Kyushu Univ, Fac Dent Sci, Dept Dent Anesthesiol, Fukuoka, Fukuoka, Japan
关键词
BAG; PREDICTION;
D O I
10.1016/j.joms.2019.08.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Mask ventilation is a basic technique for induction of anesthesia. In head and neck surgery, we have encountered difficulty in ventilation owing to facial deformities. Recently, a new type of face mask without an air cushion, the QuadraLite face mask (Intersurgical, Berkshire, UK), was developed. The aim of this study was to compare the performance of cases with predicted difficult mask ventilation between the new type of face mask and a traditional face mask. Patients and Methods: This study was a crossover prospective study. The participants were patients (aged > 18 years) who underwent oral-maxillofacial surgery under general anesthesia. The risk factors for a difficult airway were assessed. Patients were divided into 3 risk groups: low risk, 0 or 1 risk factor for predicted difficult mask ventilation; medium risk, 2 or 3 risk factors; and high risk, 4 or more risk factors. An air cushion face mask (Koo Medical, Shanghai, China) and the QuadraLite face mask were applied in turn under the setting of pressure-controlled ventilation. The expiratory tidal volumes were compared between these face masks. Results: A total of 48 patients were included: 16 in the low-risk group, 16 in the medium-risk group, and 16 in the high-risk group. Higher expiratory tidal volumes were observed with the QuadraLite face mask than with the air cushion face mask, although the differences did not reach the statistically significant level: 574.3 +/- 62.7 mL versus 553.1 +/- 60.6 mL in the low-risk group (P = .44), 553.1 +/- 112.9 mL versus 536.4 +/- 114.2 mL in the medium-risk group (P = .38), and 560.0 +/- 98.6 mL versus 548.2 +/- 07.1 mL in the high-risk group (P = .22). In all cases, a sufficient ventilation volume was obtained by the QuadraLite face mask. Conclusions: The QuadraLite face mask is compact because there is no air cushion, and it can provide sufficient mask ventilation as well as a traditional face mask with an air cushion even in patients with a difficult airway. (C) 2019 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:2465.e1 / 2465.e5
页数:5
相关论文
共 50 条
  • [1] Comparison of face masks in the bag-mask ventilation of a manikin
    Redfern, D
    Rassam, S
    Stacey, MR
    Mecklenburgh, JS
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (02) : 169 - 172
  • [2] Reusability of face masks: Influence of washing and comparison of performance between medical face masks and community face masks
    Whyte, Henrietta Essie
    Joubert, Aurelie
    Leclerc, Lara
    Sarry, Gwendoline
    Verhoeven, Paul
    Le Coq, Laurence
    Pourchez, Jeremie
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2022, 28
  • [3] Impact of Foam Cushion Mask on Common Patient Issues with Full Face Masks
    Valentine, K.
    Hevener, W.
    Blase, A.
    Garcia, A.
    Scheuller, H. S.
    Benjafield, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [4] Speech air flow with and without face masks
    Derrick, Donald
    Kabaliuk, Natalia
    Longworth, Luke
    Pishyar-Dehkordi, Peiman
    Jermy, Mark
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] Speech air flow with and without face masks
    Donald Derrick
    Natalia Kabaliuk
    Luke Longworth
    Peiman Pishyar-Dehkordi
    Mark Jermy
    Scientific Reports, 12
  • [6] FACE MASK VENTILATION: A COMPARISON OF THREE TECHNIQUES
    Hart, Danielle
    Reardon, Robert
    Ward, Christopher
    Miner, James
    JOURNAL OF EMERGENCY MEDICINE, 2013, 44 (05): : 1028 - 1033
  • [7] Noninvasive CPAP With Face Mask: Comparison Among New Air-Entrainment Masks and the Boussignac Valve
    Mistraletti, Giovanni
    Giacomini, Matteo
    Sabbatini, Giovanni
    Pinciroli, Riccardo
    Mantovani, Elena S.
    Umbrello, Michele
    Palmisano, Debora
    Formenti, Paolo
    Destrebecq, Anne L. L.
    Iapichino, Gaetano
    RESPIRATORY CARE, 2013, 58 (02) : 305 - 312
  • [8] UIBVFED-Mask: A Dataset for Comparing Facial Expressions with and without Face Masks
    Mascaro-Oliver, Miquel
    Mas-Sanso, Ramon
    Amengual-Alcover, Esperanca
    Roig-Maimo, Maria Francesca
    DATA, 2023, 8 (01)
  • [9] Performance comparison between mixing ventilation and displacement ventilation with and without cooled ceiling
    Wang, Qiu-Wang
    Zhao, Zhen
    ENGINEERING COMPUTATIONS, 2006, 23 (3-4) : 218 - 237
  • [10] In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks
    Lin, Hui-Ling
    Lee, Yu-Chi
    Wang, Ssu-Hui
    Chiang, Li-Ying
    Liu, Jui-Fang
    HEALTHCARE, 2020, 8 (04)