Analysis of Segmental Cervical Spine Vertebral Motion After Prodisc-C Cervical Disc Replacement

被引:27
|
作者
Park, Justin J. [1 ]
Quirno, Martin [1 ]
Cunningham, Mary R. [2 ]
Schwarzkopf, Ran [1 ]
Bendo, John A. [1 ]
Spivak, Jeffrey M. [1 ]
Goldstein, Jeffrey A. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed Surg, New York, NY 10003 USA
[2] Orthoped Int Spine, Seattle, WA USA
关键词
cervical disc prosthesis; artificial disc; cervical spine; intervertebral disc; spinal arthroplasty; range of motion; RADICULOPATHY; DISKECTOMY;
D O I
10.1097/BRS.0b013e3181c88165
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Retrospective study of patients enrolled in a prospective randomized Food and Drug Administration trial with single level cervical disc replacement (CDR) with the ProDisc-C (Synthes, Paoli, PA). Objective. Evaluate the segmental range of motion ( ROM) in the cervical spine pre- and postoperative after CDR. Summary of Background Information. Each cervical level is believed to have its own biomechanical characteristics, ultimately leading to different sagittal and lateral ROM. Our understanding of the factors that influence motion after CDR continues to change and expand. Methods. One hundred sixty-four patients with single level ProDisc-C arthroplasty were evaluated radiographically using Medical Metrics (QMATM, Medical Metrics, Inc., Houston, TX). Pre- and postoperative disc height and ROM were measured from standing lateral and flexion-extension radiographs. Of these 164 patients, 44 had a CDR at C6/C7, 96 at C5/C6, 18 at C4/C5, and 6 at C3/C4. The mean follow-up was of 24 months. Statistical analysis evaluated the difference in mean ROM between the groups. Results. Before surgery, C4/C5 had more sagittal ROM compared with C3/C4, C5/C6, and C6/C7 (P < 0.001.) Before surgery, C4/C5 also had more lateral ROM compared with C3/C4, C5/C6, and C6/C7 (P = 0.015). After surgery, there were no significant differences in sagittal and lateral ROM between C3/C4, C4/C5, C5/C6, and C6/C7. The delta ( difference between pre- and postoperative) proved that the C4/C5 CDR actually lost sagittal ROM (-2.5 degrees) compared with the other levels, which gained sagittal ROM, C3/C4 (0.9), C5/C6 (1.8), and C6/C7 (1.6); P = 0.037. There was no significant difference in the delta lateral ROM between the segments: C3/C4, C4/C5, C5/C6, and C6/C7. Conclusion. CDR approximates the different segmental sagittal and lateral ROM. Although C4/C5 had negative delta ROM in the sagittal and lateral planes, it provided a satisfactory final ROM. Long-term clinical outcome studies are needed to properly evaluate if these differences could ultimately affect the patients everyday life.
引用
收藏
页码:E285 / E289
页数:5
相关论文
共 50 条
  • [31] Prosthesis design influences segmental contribution to total cervical motion after cervical disc arthroplasty
    Patwardhan, Avinash G.
    Havey, Robert M.
    EUROPEAN SPINE JOURNAL, 2020, 29 (11) : 2713 - 2721
  • [32] Prosthesis design influences segmental contribution to total cervical motion after cervical disc arthroplasty
    Avinash G. Patwardhan
    Robert M. Havey
    European Spine Journal, 2020, 29 : 2713 - 2721
  • [33] Longitudinal assessment of segmental motion of the cervical spine following total disc arthroplasty: a comparative analysis of devices
    Colman, Matthew W.
    Zavras, Athan G.
    Federico, Vincent P.
    Nolte, Michael T.
    Butler, Alexander J.
    Singh, Kern
    Phillips, Frank M.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 37 (04) : 556 - 562
  • [34] Total Cervical Disk Replacement - Implant-Specific Approaches: Keel Implant (Prodisc-C Intervertebral Disk Prosthesis)
    Korge, Andreas
    Siepe, Christoph J.
    Heider, Franziska
    Mayer, H. Michael
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2010, 22 (5-6): : 480 - 494
  • [35] Segmental Motion of the Cervical Spine After Total Disc Replacement Using ActivC Versus Discectomy and Fusion Using Stand-alone Cage
    Kim, Bum-Joon
    Kim, Se-Hoon
    Lee, Seung-Hwan
    Ha, Sung-Kon
    Kim, Sang-Dae
    Lim, Dong-Jun
    WORLD NEUROSURGERY, 2019, 126 : E1228 - E1234
  • [36] Correlation of ProDisc-C failure strength with cervical bone mineral content and endplate strength
    Zhang, Xingkai
    Ordway, Nathaniel R.
    Tan, Rong
    Rim, Byeong Cheol
    Fayyazi, Amir H.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (06): : 400 - 405
  • [37] Biomechanical behavior of two different cervical total disc replacement designs in relation of concavity of articular surfaces: ProDisc-C® vs. Prestige-LP®
    Tae-Gon Jung
    Su-Heon Woo
    Kwang-Min Park
    Jong-Wook Jang
    Dong-Wook Han
    Sung Jae Lee
    International Journal of Precision Engineering and Manufacturing, 2013, 14 : 819 - 824
  • [38] Biomechanical analysis of cervical range of motion and facet contact force after a novel artificial cervical disc replacement
    Zhao, Xin
    Yuan, Wei
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (05): : 3109 - 3115
  • [39] Biomechanical analysis of cervical range of motion and facet contact force after a novel artificial cervical disc replacement
    Huang, Kangkang
    Wu, Tingkui
    Wang, Beiyu
    Liu, Hao
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (10):
  • [40] ProDisc-C Total Disc Replacement. A Four-Year Prospective Monocentric Study
    Barna, M.
    Stulik, J.
    Kryl, J.
    Vyskocil, T.
    Nesnidal, P.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (06) : 512 - 519