Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?

被引:21
|
作者
Lazennec, Jean Yves [1 ]
Chometon, Quentin [1 ]
Folinais, Dominique [1 ]
Robbins, Christopher B. [1 ]
Pour, Aidin Eslam [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Knee; Coronal knee alignment; Hip-knee-ankle angle; Three-dimensional imaging; Radiographs; HIGH TIBIAL OSTEOTOMY; LOWER-LIMB; ARTHROPLASTY; VARUS; OSTEOARTHRITIS; PROGRESSION; RECONSTRUCTION; RADIOGRAPHS; DEFORMITY; SURVIVAL;
D O I
10.1007/s00264-016-3340-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Coronal malalignment of the lower extremity is closely related to the onset and progression of osteoarthritis. Restoring satisfactory alignment after tibial osteotomy improves the long-term success of this conservative surgery. The purpose of our study was to determine (1) if there is a difference between two-dimensional (2D) and 3D measurements of the hip-knee-ankle (HKA) angle between the mechanical axes of the femur and the tibia, (2) which parameter most affects 2D-3D HKA measurement, and (3) the percentage of patients who are at risk of error in HKA measurement. Methods We reviewed imaging studies of the consecutive patients referred to us for hip or knee pain between June and October 2013. Patients with previous pelvis or lower extremity surgery were excluded. Results In 51 % (95/186) of lower extremities examined, the 3D method showed more valgus than the 2D method, and in 49 % (91/186), the 3D method showed more varus. In 12 % of extremities (23/186), the knee varus or valgus alignment was completely opposite in 3D images compared to 2D images. Having more than 7A degrees of flexum/recurvatum alignment increased error in 2D HKA measurement by 5.7A degrees. This was calculated to be 0.15A degrees per 1A degrees increase in femoral torsion and 0.05A degrees per 1A degrees increase in tibial torsion. Approximately 20 % of patients might be at risk of error in HKA angle measurement in 2D imaging studies. Conclusions Orthopaedic surgeons should assess lower extremity alignment in standing position, with enough exposure of the extremity to find severe alignment or rotational deformities, and consider advanced 3D images of those patients who have them. Otherwise, HKA angle can be measured with good accuracy with 2D techniques.
引用
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [31] Three-Dimensional Imaging Analysis of Unicompartmental Knee Arthroplasty Evaluated in Standing Position: Component Alignment and In Vivo Articular Contact
    Tsai, Tsung-Yuan
    Dimitriou, Dimitris
    Liow, Ming Han Lincoln
    Rubash, Harry E.
    Li, Guoan
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2016, 31 (05): : 1096 - 1101
  • [32] Three-dimensional biometrics using weight-bearing imaging shows relationship between knee and hindfoot axial alignment
    Dufrenot, Maryama
    Dagneaux, Louis
    Fernando, Celine
    Chabrand, Patrick
    Ollivier, Matthieu
    Lintz, Francois
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (05)
  • [33] Surgical epicondylar axis is not orthogonal to the femoral mechanical knee axis in valgus knees with primary osteoarthritis: Three-dimensional analysis according to knee coronal alignment in 112 patients
    Sariali, Elhadi
    Moussellard, Hugues Pascal
    KNEE, 2022, 39 : 91 - 99
  • [34] Automated image registration for assessing three-dimensional alignment of entire lower extremity and implant position using bi-plane radiography
    Kobayashi, Koichi
    Sakamoto, Makoto
    Tanabe, Yuji
    Ariumi, Akihiro
    Sato, Takashi
    Omori, Go
    Koga, Yoshio
    JOURNAL OF BIOMECHANICS, 2009, 42 (16) : 2818 - 2822
  • [35] Contribution of sex and body constitution to three-dimensional lower extremity alignment for healthy, elderly, non-obese humans in a Japanese population
    Katsumi R.
    Mochizuki T.
    Sato T.
    Kobayashi K.
    Watanabe S.
    Tanifuji O.
    Endo N.
    Journal of Experimental Orthopaedics, 5 (1)
  • [36] Three dimensional radiological imaging of normal lower-limb alignment in children
    Ádám Tibor Schlégl
    Kinga Szuper
    Szabolcs Somoskeöy
    Péter Than
    International Orthopaedics, 2015, 39 : 2073 - 2080
  • [37] Three dimensional radiological imaging of normal lower-limb alignment in children
    Schlegl, Adam Tibor
    Szuper, Kinga
    Somoskeoey, Szabolcs
    Than, Peter
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (10) : 2073 - 2080
  • [38] Three-Dimensional Finite Analysis of the Optimal Alignment of the Tibial Implant in Unicompartmental Knee Arthroplasty
    Sasatani, Katsumi
    Majima, Tokifumi
    Murase, Kohei
    Takeuchi, Naoki
    Matsumoto, Takeo
    Oshima, Yasushi
    Takai, Shinro
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2020, 87 (02) : 60 - 65
  • [39] Comparison of three-dimensional lower extremity running kinematics of young adult and elderly runners
    Fukuchi, Reginaldo K.
    Duarte, Marcos
    JOURNAL OF SPORTS SCIENCES, 2008, 26 (13) : 1447 - 1454
  • [40] Three-Dimensional Imaging of Intraplaque Neovascularization in a Mouse Model of Advanced Atherosclerosis
    Perrotta, Paola
    Pintelon, Isabel
    de Vries, Margreet R.
    Quax, Paul H. A.
    Timmermans, Jean-Pierre
    De Meyer, Guido R. Y.
    Martinet, Wim
    JOURNAL OF VASCULAR RESEARCH, 2020, 57 (06) : 348 - 354