Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?

被引:21
|
作者
Lazennec, Jean Yves [1 ]
Chometon, Quentin [1 ]
Folinais, Dominique [1 ]
Robbins, Christopher B. [1 ]
Pour, Aidin Eslam [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Knee; Coronal knee alignment; Hip-knee-ankle angle; Three-dimensional imaging; Radiographs; HIGH TIBIAL OSTEOTOMY; LOWER-LIMB; ARTHROPLASTY; VARUS; OSTEOARTHRITIS; PROGRESSION; RECONSTRUCTION; RADIOGRAPHS; DEFORMITY; SURVIVAL;
D O I
10.1007/s00264-016-3340-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Coronal malalignment of the lower extremity is closely related to the onset and progression of osteoarthritis. Restoring satisfactory alignment after tibial osteotomy improves the long-term success of this conservative surgery. The purpose of our study was to determine (1) if there is a difference between two-dimensional (2D) and 3D measurements of the hip-knee-ankle (HKA) angle between the mechanical axes of the femur and the tibia, (2) which parameter most affects 2D-3D HKA measurement, and (3) the percentage of patients who are at risk of error in HKA measurement. Methods We reviewed imaging studies of the consecutive patients referred to us for hip or knee pain between June and October 2013. Patients with previous pelvis or lower extremity surgery were excluded. Results In 51 % (95/186) of lower extremities examined, the 3D method showed more valgus than the 2D method, and in 49 % (91/186), the 3D method showed more varus. In 12 % of extremities (23/186), the knee varus or valgus alignment was completely opposite in 3D images compared to 2D images. Having more than 7A degrees of flexum/recurvatum alignment increased error in 2D HKA measurement by 5.7A degrees. This was calculated to be 0.15A degrees per 1A degrees increase in femoral torsion and 0.05A degrees per 1A degrees increase in tibial torsion. Approximately 20 % of patients might be at risk of error in HKA angle measurement in 2D imaging studies. Conclusions Orthopaedic surgeons should assess lower extremity alignment in standing position, with enough exposure of the extremity to find severe alignment or rotational deformities, and consider advanced 3D images of those patients who have them. Otherwise, HKA angle can be measured with good accuracy with 2D techniques.
引用
下载
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [21] Three-dimensional ultrasound of a massive fetal lymphangioma involving the lower extremity
    Schild, RL
    Orhan, Y
    Meyberg, H
    Braunschweig, T
    Knöpfle, G
    Gembruch, U
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (05) : 547 - 549
  • [22] Three-dimensional ultrasonography of the fetal distal lower extremity: Normal and abnormal
    Budorick, NE
    Pretorius, DH
    Johnson, DD
    Nelson, TR
    Tartar, MK
    Lou, KV
    JOURNAL OF ULTRASOUND IN MEDICINE, 1998, 17 (10) : 649 - 660
  • [23] Pelvic and lower extremity arterial imaging: Diagnostic performance of three-dimensional contrast-enhanced MR angiography
    Ruehm, SG
    Hany, TF
    Pfammatter, T
    Schneider, E
    Ladd, M
    Debatin, JF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) : 1127 - 1135
  • [24] Establishing and Running a Three-dimensional and Advanced Imaging Laboratory
    Cook, Tessa S.
    Steingall, Samantha J.
    Steingall, Scott R.
    Boonn, William W.
    RADIOGRAPHICS, 2018, 38 (06) : 1799 - 1809
  • [25] Quantification of articular cartilage in the knee with three-dimensional MR imaging
    Dupuy, DE
    Spillane, RM
    Rosol, MS
    Rosenthal, DI
    Palmer, WE
    Burke, DW
    Rosenberg, AE
    ACADEMIC RADIOLOGY, 1996, 3 (11) : 919 - 924
  • [26] High resolution three-dimensional knee cartilage imaging with FEMR
    Gold, GE
    Shimakawa, A
    Brittain, JH
    Hargreaves, BA
    Pauly, JM
    Beaulieu, CF
    RADIOLOGY, 2002, 225 : 656 - 657
  • [27] The visible man: Three-dimensional interactive musculoskeletal anatomic atlas of the lower extremity
    Kang, HS
    Kim, BH
    Ryu, JW
    Hong, SH
    Chung, HW
    Cho, SY
    Kim, YH
    Hwang, SI
    Jeong, DK
    Shin, YG
    RADIOGRAPHICS, 2000, 20 (01) : 279 - 286
  • [28] Three-dimensional lower extremity kinematics of Chinese during activities of daily living
    Han, Shuyang
    Cheng, Gang
    Xu, Peng
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2015, 28 (02) : 327 - 334
  • [29] A three-dimensional model of transient bioheat transfer in the lower extremity during cryotherapy
    Zare, Parvaneh
    Ghoraishian, Mohammad
    Khorasani, Ahmadreza Faghih
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (12) : 1413 - 1420
  • [30] Three-dimensional analytical model of microwave imaging of the lower leg
    Zhang, Guoji
    Wu, Xiangying
    Ji, Fei
    Wang, Yifang
    Lai, Shengli