Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?

被引:21
|
作者
Lazennec, Jean Yves [1 ]
Chometon, Quentin [1 ]
Folinais, Dominique [1 ]
Robbins, Christopher B. [1 ]
Pour, Aidin Eslam [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Knee; Coronal knee alignment; Hip-knee-ankle angle; Three-dimensional imaging; Radiographs; HIGH TIBIAL OSTEOTOMY; LOWER-LIMB; ARTHROPLASTY; VARUS; OSTEOARTHRITIS; PROGRESSION; RECONSTRUCTION; RADIOGRAPHS; DEFORMITY; SURVIVAL;
D O I
10.1007/s00264-016-3340-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Coronal malalignment of the lower extremity is closely related to the onset and progression of osteoarthritis. Restoring satisfactory alignment after tibial osteotomy improves the long-term success of this conservative surgery. The purpose of our study was to determine (1) if there is a difference between two-dimensional (2D) and 3D measurements of the hip-knee-ankle (HKA) angle between the mechanical axes of the femur and the tibia, (2) which parameter most affects 2D-3D HKA measurement, and (3) the percentage of patients who are at risk of error in HKA measurement. Methods We reviewed imaging studies of the consecutive patients referred to us for hip or knee pain between June and October 2013. Patients with previous pelvis or lower extremity surgery were excluded. Results In 51 % (95/186) of lower extremities examined, the 3D method showed more valgus than the 2D method, and in 49 % (91/186), the 3D method showed more varus. In 12 % of extremities (23/186), the knee varus or valgus alignment was completely opposite in 3D images compared to 2D images. Having more than 7A degrees of flexum/recurvatum alignment increased error in 2D HKA measurement by 5.7A degrees. This was calculated to be 0.15A degrees per 1A degrees increase in femoral torsion and 0.05A degrees per 1A degrees increase in tibial torsion. Approximately 20 % of patients might be at risk of error in HKA angle measurement in 2D imaging studies. Conclusions Orthopaedic surgeons should assess lower extremity alignment in standing position, with enough exposure of the extremity to find severe alignment or rotational deformities, and consider advanced 3D images of those patients who have them. Otherwise, HKA angle can be measured with good accuracy with 2D techniques.
引用
下载
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [1] Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?
    Jean Yves Lazennec
    Quentin Chometon
    Dominique Folinais
    Christopher B. Robbins
    Aidin Eslam Pour
    International Orthopaedics, 2017, 41 : 917 - 924
  • [2] Three-dimensional lower extremity alignment assessment system - Application to evaluation of component position after total knee arthroplasty
    Sato, T
    Koga, Y
    Omori, G
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 620 - 628
  • [3] Relationship Between Coronal Alignment and Rotational Profile of Lower Extremity in Patients With Knee Osteoarthritis
    Chang, Moon Jong
    Jeong, Hyeon Jang
    Kang, Seung-Baik
    Chang, Chong Bum
    Yoon, Chan
    Shin, Joung Youp
    JOURNAL OF ARTHROPLASTY, 2018, 33 (12): : 3773 - 3777
  • [4] The three-dimensional determination of internal loads in the lower extremity
    Institute of Biomechanics, German Sport University Cologne, Carl-Diem-Weg 6, D50927 Cologne, Germany
    J. Biomech., 11-12 (1123-1131):
  • [5] The three-dimensional determination of internal loads in the lower extremity
    Glitsch, U
    Baumann, W
    JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) : 1123 - 1131
  • [6] Three-Dimensional Biometrics to Correlate Hindfoot and Knee Coronal Alignments Using Modern Weightbearing Imaging
    Dagneaux, Louis
    Dufrenot, Maryama
    Bernasconi, Alessio
    Bedard, Nicholas A.
    de Cesar Netto, Cesar
    Lintz, Francois
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (11) : 1411 - 1418
  • [7] Three-dimensional imaging of the uterus: The value of the coronal plane
    Wong, Lufee
    White, Nikki
    Ramkrishna, Jayshree
    Araujo Junior, Edward
    Meagher, Simon
    Costa, Fabricio Da Silva
    WORLD JOURNAL OF RADIOLOGY, 2015, 7 (12): : 484 - 493
  • [8] Three-dimensional polarimetric imaging of coronal mass ejections
    Moran, TG
    Davila, JM
    SCIENCE, 2004, 305 (5680) : 66 - 70
  • [9] Three-dimensional lower extremity alignment in the weight-bearing standing position in healthy elderly subjects
    Ariumi, Akihiro
    Sato, Takashi
    Kobayashi, Koichi
    Koga, Yoshio
    Omori, Go
    Minato, Izumi
    Endo, Naoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (01) : 64 - 70
  • [10] Three-dimensional computed tomographic angiography in lower extremity revascularization
    Ishikawa, M
    Morimoto, N
    Sasajima, T
    Kubo, Y
    SURGERY TODAY, 1999, 29 (03) : 243 - 247