Rapid and Sensitive Detection of Microcystin-LR using THz-Aptamer Biosensor

被引:0
|
作者
Mohamed, Ahmed [1 ]
Walsh, Ryan [2 ]
Ropagnol, Xavier [1 ]
Perreault, Jonathan [2 ]
Ozaki, Tsuneyuki [1 ]
机构
[1] Nstitut Natl Rech Sci Energie Mat Telecommun, Varennes, PQ J3X 1S2, Canada
[2] INRS Ctr Armand Frappier Sante Biotechnol, Laval, PQ H7V 1B7, Canada
关键词
D O I
10.1109/IRMMW-THz50926.2021.9567267
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A combination of Terahertz (THz) emission and aptamer technologies has a crucial impact on the highly sensitive and rapid detection of small toxic molecules such as microcystin-LR (MC-LR). THz chemical microscope (TCM) is a unique THz aptasensor that has been successfully used for monitoring MC-LR molecules in buffer and complex samples. Our results show that our TCM aptasensor has an excellent detection limit of 50 ng/L as well as the assay time is about 15 min. Compared with other biosensors such as surface plasmon resonance (SPR), our TCM aptasensor provides a rapid and sensitive assay.
引用
收藏
页数:1
相关论文
共 50 条
  • [31] Immunochromatographic Test Systems for Detection of Microcystin-LR in Seafood
    Zvereva, E. A.
    Hendrickson, O. D.
    Zherdev, A., V
    Dzantiev, B. B.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2021, 57 (03) : 403 - 409
  • [32] Cloning of scFv from hybridomas using a rational strategy: Application as a receptor to sensitive detection microcystin-LR in water
    Zhang, Xiuyuan
    He, Kuo
    Zhao, Ruiping
    Wang, Lixia
    Jin, Yandan
    CHEMOSPHERE, 2016, 160 : 230 - 236
  • [33] Label-Free Voltammetric Aptasensor for the Sensitive Detection of Microcystin-LR Using Graphene-Modified Electrodes
    Eissa, Shimaa
    Ng, Andy
    Siaj, Mohamed
    Zourob, Mohammed
    ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7551 - 7557
  • [34] Rapid microcystin-LR detection using antibody-based electrochemical biosensors with a simplified calibration curve approach
    Samuel Adjei-Nimoh
    Lance-Nicolas Rances
    Maha A. Tony
    Hossam A. Nabwey
    Woo Hyoung Lee
    Scientific Reports, 14 (1)
  • [35] A novel dendritic surfactant for enhanced microcystin-LR detection by double amplification in a quartz crystal microbalance biosensor
    Xia, Yuetong
    Zhang, Jianping
    Jiang, Long
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 86 (01) : 81 - 86
  • [36] Label-Free Sensitive Detection of Microcystin-LR via Aptamer-Conjugated Gold Nanoparticles Based on Solid-State Nanopores
    He, Feng
    Liang, Liyuan
    Zhou, Shuo
    Xie, Wanyi
    He, Shixuan
    Wang, Yunjiao
    Tlili, Chaker
    Tong, Shoufeng
    Wang, Deqiang
    LANGMUIR, 2018, 34 (49) : 14825 - 14833
  • [37] Qualitative and quantitative detection of microcystin-LR based on SERS-FET dual-mode biosensor
    Tian, Meng
    Wang, Jihua
    Li, Chonghui
    Wang, Zhenxing
    Liu, Guofeng
    Lv, Enguang
    Zhao, Xiaofei
    Li, Zhen
    Cao, Dongyan
    Liu, Huilan
    Zhang, Chao
    Xu, Shicai
    Man, Baoyuan
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [38] Qualitative and quantitative detection of microcystin-LR based on SERS-FET dual-mode biosensor
    Tian, Meng
    Wang, Jihua
    Li, Chonghui
    Wang, Zhenxing
    Liu, Guofeng
    Lv, Enguang
    Zhao, Xiaofei
    Li, Zhen
    Cao, Dongyan
    Liu, Huilan
    Zhang, Chao
    Xu, Shicai
    Man, Baoyuan
    BIOSENSORS & BIOELECTRONICS, 2022, 212
  • [39] All in laser-induced graphene to fabricate the electrochemical biosensor for on-site detection of microcystin-LR
    Chen, Zuo
    Dong, Na
    Wang, Yuan
    Li, Yuqing
    Li, Wenjia
    Liu, Dong
    You, Tianyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 419
  • [40] An aptamer based fluorometric microcystin-LR assay using DNA strand-based competitive displacement
    Raja Chinnappan
    Razan AlZabn
    Khalid M. Abu-Salah
    Mohammed Zourob
    Microchimica Acta, 2019, 186