Liquid Embolic Agents for Endovascular Embolization: Evaluation of an Established (Onyx) and a Novel (PHIL) Embolic Agent in an In Vitro AVM Model

被引:36
|
作者
Vollherbst, D. F. [1 ]
Sommer, C. M. [2 ,3 ]
Ulfert, C. [1 ]
Pfaff, J. [1 ]
Bendszus, M. [1 ]
Moehlenbruch, M. A. [1 ]
机构
[1] Univ Hosp Heidelberg, Dept Neuroradiol, INF 400, D-69120 Heidelberg, Germany
[2] Univ Hosp Heidelberg, Clin Diagnost & Intervent Radiol, Heidelberg, Germany
[3] Klinikum Stuttgart, Clin Diagnost & Intervent Radiol, Stuttgart, Germany
关键词
BRAIN ARTERIOVENOUS-MALFORMATIONS; HYDROPHOBIC INJECTABLE LIQUID; PRELIMINARY EXPERIENCE; CYANOACRYLATE;
D O I
10.3174/ajnr.A5203
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model. MATERIALS AND METHODS: An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed. RESULTS: Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 mu L; P < .001). CONCLUSIONS: While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization.
引用
收藏
页码:1377 / 1382
页数:6
相关论文
共 39 条
  • [31] Endovascular treatment of high-flow cervical direct vertebro-vertebral arteriovenous fistula with detachable coils and Onyx liquid embolic agent
    Qihong Wang
    Donglei Song
    Gong Chen
    Acta Neurochirurgica, 2011, 153 : 347 - 352
  • [32] Extending Endovascular Embolization to Type A Spinal Perimedullary Arteriovenous Fistula Using Liquid Embolic Agent: Technical Nuances, Challenges and Initial Outcome
    Malik, Virender
    Kannath, Santhosh Kumar
    Rajan, Jayadevan Enakshy
    Lukas, Jospaul
    WORLD NEUROSURGERY, 2018, 119 : 267 - 273
  • [33] ihtObtura: A novel liquid embolic agent with post-embolization radiopacity loss, in endovascular treatment of brain arteriovenous malformations, dural arteriovenous fistulas, and tumors: CLARIDAD trial
    Llibre-Guerra, Juan Carlos
    Guimaraens, Leopoldo
    Kadziolka, Krzysztof Bartosz
    Siddiqui, Adnan H.
    Chapot, Rene
    Gil, Alberto
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [34] Endovascular Treatment of Chronic Subdural Hematomas through Embolization: A Pilot Study with a Non-Adhesive Liquid Embolic Agent of Minimal Viscosity (Squid)
    Petrov, Andrey
    Ivanov, Arkady
    Rozhchenko, Larisa
    Petrova, Anna
    Bhogal, Pervinder
    Cimpoca, Alexandru
    Henkes, Hans
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)
  • [35] Efficacy and Hemodynamic Impact of Net-Type Embolic Protection Devices for Endovascular Interventions: Evaluation in an In Vitro Model
    Sanchez-Nevarez, Manuel Ignacio
    Plana, Emma
    Arrebola, Manuel
    Miralles, Manuel
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (04) : 29S - 29S
  • [36] The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
    Schmitt, Niclas
    Weyland, Charlotte S.
    Wucherpfennig, Lena
    Sommer, Christof M.
    Bendszus, Martin
    Moehlenbruch, Markus A.
    Vollherbst, Dominik F.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (08) : 832 - 836
  • [37] Liquid embolic agent Fe3O4-EVOH for endovascular arteriovenous malformation embolisation: Preliminary evaluation in an in vivo swine rete mirabile model
    Li, Wei
    Liang, Shikai
    Zhang, Wei
    Zhao, Xuelian
    Zhang, Huifang
    Lv, Xianli
    NEURORADIOLOGY JOURNAL, 2020, 33 (04): : 306 - 310
  • [38] Evaluation of a Novel Liquid Embolic Material Using a Rabbit Model: A Hydrophilic Polymer Composite Activated by the Ca2+in the Blood
    Yuki, Ichiro
    Ohkawa, Kousaku
    Hsu, Frank P.
    Xu, Jordan C.
    Suzuki, Shuichi
    STROKE, 2020, 51
  • [39] Computational modeling and simulation for endovascular embolization of cerebral arteriovenous malformations with liquid embolic agents液态栓塞剂栓塞脑动静脉畸形的计算流体力学建模与仿真
    Bowen Zhang
    Xi Chen
    Xiaolong Zhang
    Guanghong Ding
    Liang Ge
    Shengzhang Wang
    Acta Mechanica Sinica, 2024, 40