Liquid Embolic Agents for Endovascular Embolization: Evaluation of an Established (Onyx) and a Novel (PHIL) Embolic Agent in an In Vitro AVM Model

被引:36
|
作者
Vollherbst, D. F. [1 ]
Sommer, C. M. [2 ,3 ]
Ulfert, C. [1 ]
Pfaff, J. [1 ]
Bendszus, M. [1 ]
Moehlenbruch, M. A. [1 ]
机构
[1] Univ Hosp Heidelberg, Dept Neuroradiol, INF 400, D-69120 Heidelberg, Germany
[2] Univ Hosp Heidelberg, Clin Diagnost & Intervent Radiol, Heidelberg, Germany
[3] Klinikum Stuttgart, Clin Diagnost & Intervent Radiol, Stuttgart, Germany
关键词
BRAIN ARTERIOVENOUS-MALFORMATIONS; HYDROPHOBIC INJECTABLE LIQUID; PRELIMINARY EXPERIENCE; CYANOACRYLATE;
D O I
10.3174/ajnr.A5203
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model. MATERIALS AND METHODS: An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed. RESULTS: Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 mu L; P < .001). CONCLUSIONS: While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization.
引用
收藏
页码:1377 / 1382
页数:6
相关论文
共 39 条
  • [21] In Vitro Assessment of Aortic Stent-Graft Integrity following Exposure to Onyx Liquid Embolic Agent
    Stone, James R.
    Evans, Avery J.
    Angle, John F.
    Arslan, Bulent
    Turba, Ulku C.
    Matsumoto, Alan H.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (01) : 107 - 112
  • [22] Evaluation of Multiple Embolic Agents for Embolization of the Superior Rectal Artery in an Animal Model
    Farouk Tradi
    Julien Panneau
    Pauline Brige
    Diane Mege
    Paul Habert
    Jean Francois Hak
    Mathieu Di Bisceglie
    Vincent Vidal
    CardioVascular and Interventional Radiology, 2022, 45 : 510 - 519
  • [23] Regarding "Embolization of Intracranial Dural Arteriovenous Fistulas Using PHIL Liquid Embolic Agent in 26 Patients: A Multicenter Study"
    Bhatia, V.
    Kumar, A.
    Khandelwal, N.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (06) : E38 - E38
  • [24] Iodinated Cyanoacrylate-Based Novel Liquid Embolic Compositions with Inherent Radiopacity for Endovascular Embolization
    Jeon, Seong Ik
    Park, Hyun Jae
    Cho, Hanhee
    Hur, Saebeom
    Kim, Young Il
    Jae, Hwan Jun
    Ahn, Cheol-Hee
    Advanced Healthcare Materials, 2024, 13 (29)
  • [25] Evaluation of a Hydrogel Liquid Embolic Agent in a Porcine Mesenteric Hemorrhage Model
    Gandras, Eric John
    Jarrett, Timothy
    Lareau, Raymond
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 33 (06) : 653 - 659
  • [26] Imaging Artifacts of Liquid Embolic Agents on Conventional CT in an Experimental in Vitro Model
    Schmitt, N.
    Floca, R. O.
    Paech, D.
    El Shafie, R. A.
    Seker, F.
    Bendszus, M.
    Moehlenbruch, M. A.
    Vollherbst, D. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (01) : 126 - 131
  • [27] Real-Time MRI Monitoring of Liquid Embolic Agent (Onyx) Injection in a Swine Arteriovenous Malformation Model
    Zawadzki, Michal
    Pinkiewicz, Milosz
    Pinkiewicz, Mateusz
    Walecki, Jerzy
    Walczak, Piotr
    Golubczyk, Dominika
    Sady, Maria
    Gajewski, Zdzislaw
    BRAIN SCIENCES, 2023, 13 (06)
  • [28] Embolization of spinal intramedullary arteriovenous malformations using the liquid embolic agent, Onyx: a single-center experience in a series of 17 patients
    Corkill, Rufus A.
    Mitsos, Aristotelis P.
    Molyneux, Andrew J.
    JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (05) : 478 - 485
  • [29] In vitro comparison of middle meningeal artery embolization with Squid liquid embolic agent and Contour polyvinyl alcohol particles
    Sadasivan, Chander
    Dashti, Nakisa
    Marfoglio, Samantha
    Fiorella, David
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (03) : 280 - 284
  • [30] Endovascular treatment of high-flow cervical direct vertebro-vertebral arteriovenous fistula with detachable coils and Onyx liquid embolic agent
    Wang, Qihong
    Song, Donglei
    Chen, Gong
    ACTA NEUROCHIRURGICA, 2011, 153 (02) : 347 - 352