Microwave-assisted digestion using diluted nitric acid for further trace elements determination in biodiesel by SF-ICP-MS

被引:28
|
作者
Barela, P. S. [1 ]
Silva, N. A. [1 ]
Pereira, J. S. F. [1 ]
Marques, J. C. [2 ]
Rodrigues, L. F. [3 ]
Moraes, D. P. [1 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Chem, BR-91501970 Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Lab Isotope Geol, BR-91501970 Porto Alegre, RS, Brazil
[3] Pontifical Univ Catolica Rio Grande Sul, Inst Petr & Nat Resources, BR-90619900 Porto Alegre, RS, Brazil
关键词
Microwave-assisted digestion; Diluted nitric acid; Biodiesel; Trace elements determination; SF-ICP-MS; EMISSION-SPECTROMETRY; BIOLOGICAL SAMPLES; AUXILIARY REAGENT; CLOSED VESSELS; MILK POWDER; OXYGEN; PRODUCTS;
D O I
10.1016/j.fuel.2017.05.028
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A microwave-assisted digestion (MW-AD) using diluted nitric acid and hydrogen peroxide as auxiliary reagent was proposed for the first time for biodiesel for further trace elements determination by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Biodiesel samples were digested under high-pressure closed vessels and the concentration of nitric acid (1, 2, 3.5, 7, 9.3 and 14 mol L-1) and volume of hydrogen peroxide (0, 1, 1.5, 2 and 3 mL) were evaluated in order to obtain high efficiency of digestion. The efficiency of biodiesel digestion was determined by residual carbon content and residual acidity in final solutions. Up to 700 mg of biodiesel were completely digested using 7 mol L-1 nitric acid and 2 mL of hydrogen peroxide in high-pressure quartz vessels assisted by microwave radiation at 900 W during 60 min (included 20 min for cooling step). Residual carbon content and residual acidity in digests obtained after MW-AD using optimized conditions were lower than 9 and 4%, respectively. After sample digestion, Ba, Cr, Cu, Mn, Mo, Ni, Pb, Sr, V and Zn were determined by SF-ICP-MS and analytes recoveries were in the range of 94 to 109%. Accuracy was evaluated using certified reference material (used oil) and agreement higher than 94% was achieved. Although biodiesel digestion could be performed using concentrated nitric acid, the use of diluted acid was preferable in view of the low reagent consumption and low blanks values, achieving better limits of detection (LODs) that is important aspect to green chemistry recommendations for trace elements analysis. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [41] Microwave oven digestion of power plant emissions and ICP-MS determination of trace elements
    Bettinelli, M
    Spezia, S
    Baroni, U
    Bizzarri, G
    ATOMIC SPECTROSCOPY, 1998, 19 (03) : 73 - 79
  • [42] Determination of platinum and rhodium in dust and plant samples using microwave-assisted sample digestion and ICP-MS
    Niemelä, M
    Perämäki, P
    Piispanen, J
    Poikolainen, J
    ANALYTICA CHIMICA ACTA, 2004, 521 (02) : 137 - 142
  • [43] Microwave-assisted nitric acid digestion of organic matrices
    Kubrakova, IV
    Formanovsky, AA
    Kudinova, TF
    Kuz'min, NM
    MENDELEEV COMMUNICATIONS, 1998, (03) : 93 - 94
  • [44] ICP-MS multielement determination in fly ash after microwave-assisted digestion of samples
    Das, AK
    Chakraborty, R
    de la Guardia, M
    Cervera, ML
    Goswami, D
    TALANTA, 2001, 54 (05) : 975 - 981
  • [45] Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
    Rantasa, Matjaz
    Majer, David
    Finsgar, Matjaz
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (202):
  • [46] CLOSED-VESSEL MICROWAVE-ASSISTED DIGESTION USING A DILUTED OXIDANT MIXTURE FOR TRACE ELEMENT DETERMINATION IN PETROCHEMICAL SAMPLES BY AXIALLY-VIEWED ICP OES
    Nascimento, Angerson N.
    Naozuka, Juliana
    Oliveira, Pedro V.
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 1 (03): : 131 - 135
  • [47] Rapid determination of total iodine in Japanese coastal seawater using SF-ICP-MS
    Zheng, Jian
    Takata, Hyoe
    Tagami, Keiko
    Aono, Tatsuo
    Fujita, Kazuhiro
    Uchida, Shigeo
    MICROCHEMICAL JOURNAL, 2012, 100 : 42 - 47
  • [48] ICP-MS DETERMINATION OF 45 TRACE-ELEMENTS IN WHOLE COAL USING MICROWAVE-OVEN ACID DIGESTION FOR SAMPLE PREPARATION
    FADDA, S
    RIVOLDINI, A
    CAU, I
    GEOSTANDARDS NEWSLETTER, 1995, 19 (01): : 41 - 54
  • [49] Determination of trace elements in ibuprofen drug products using microwave-assisted acid digestion and inductively coupled plasma-mass spectrometry
    Holmfred, Else
    Alrijjal, Abdulla
    Chamberlain, C. Page
    Maher, Katharine
    Sturup, Stefan
    HELIYON, 2024, 10 (01)
  • [50] Determination of trace elements in liquid aspartame sweeteners by ICP OES and ICP-MS following acid digestion
    Rafael A. de Sousa
    Anderson S. Ribeiro
    Mariana A. Vieira
    Adilson J. Curtius
    Nivaldo Baccan
    Solange Cadore
    Microchimica Acta, 2007, 159 : 241 - 246