Determination of trace elements in ibuprofen drug products using microwave-assisted acid digestion and inductively coupled plasma-mass spectrometry

被引:3
|
作者
Holmfred, Else [1 ,2 ]
Alrijjal, Abdulla [3 ]
Chamberlain, C. Page [1 ]
Maher, Katharine [2 ]
Sturup, Stefan [3 ]
机构
[1] Stanford Univ, Dept Earth & Planetary Sci, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Earth Syst Sci, Stanford, CA USA
[3] Univ Copenhagen, Dept Pharm, Copenhagen, Denmark
关键词
Ibuprofen; Pharmaceuticals; Trace elemental impurities; Acid digestion; ICP-MS; Analytical chemistry; ICP-MS; SAMPLE PREPARATION; IMPURITIES; QUANTIFICATION; VALIDATION; TABLETS;
D O I
10.1016/j.heliyon.2023.e23566
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Trace elements are found in most drugs as a result of the drug formulation and drug production methods. An inductively coupled plasma-mass spectrometry method for the determination of 24 trace elements (Mg, Ti, V, Cr, Mn, Cu, Fe, Co, Ni, Zn, As, Se, Mo, Ru, Rh, Pd, Ag, Cd, Sb, Ba, Ir, Pt, Au, and Pb) in solid ibuprofen tablets was established in relation to the ICH Q3D(R1) guideline, to evaluate the possibility of linking trace elemental profiles to drug formulation strategies, and to differentiate between drug products based on the trace elemental profiles. Ten European ibuprofen drug products were evaluated (n=3). The sample preparation was performed by microwave-assisted acid digestion using only 10 mg of homogenized sample and 900 mu L of a mix of 65% HNO3, 37% HCl, and 30% H2O2. Solid residuals primarily composed of insoluble SiO2 excipients were removed by centrifugation. Only concentrations of Mg, Fe, Ti, Mn, Cr, and Ni were detected above the limits of detection and did not exceed the ICH Q3D(R1) guideline permitted daily exposure limits. The trace elemental profiles were evaluated through principal component analysis. Three principal components describing 96% of the variance were useful in grouping the ibuprofen drug products, and the detected trace elemental remnants could be related to drug formulation and drug production strategies. An in-house quality control material was used in lack of certified reference materials and was in combination with spike recoveries used for method validation. Good spike recoveries (94-119%) were obtained for all measured trace elements except Mg. Mg showed acceptable spike recoveries (75-155%) for mid and high spike concentrations, but poor recoveries (30-223%) were detected with low spike concentrations in spike matrices containing high amounts of Mg. Overall, the method is suggested applicable for solid drugs containing insoluble SiO2 excipients and drugs comparable to ibuprofen.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Determination of Essential and Toxic Elements in Tropical Fruit by Microwave-Assisted Digestion and Inductively Coupled Plasma-Mass Spectrometry
    Habte, Girum
    Choi, Ji Yeon
    Nho, Eun Yeong
    Jamila, Nargis
    Khan, Naeem
    Hwang, In Min
    Kim, Kyong Su
    ANALYTICAL LETTERS, 2017, 50 (06) : 1025 - 1039
  • [2] Determination of trace elements in Brazilian human milk by quadrupole inductively coupled plasma mass spectrometry and microwave-assisted digestion
    Nascimento, Rosilene S.
    Mendes, Denise B. C.
    Gomes Matos, Judith Maria
    Silva, Julio C. J.
    Ciminelli, Virginia S. T.
    Neto, Waldomiro B.
    Silva, Jose Bento B.
    ATOMIC SPECTROSCOPY, 2008, 29 (03) : 77 - 82
  • [3] Development of a Method for the Microwave-assisted Digestion of Soils Using Dilute Acids and the Simultaneous Determination of 18 Trace Elements by Inductively Coupled Plasma Mass Spectrometry
    Chandrasekaran, Krishnan
    Mamatha, Puttam Reddy
    Karunasagar, Dheram
    ATOMIC SPECTROSCOPY, 2015, 36 (05) : 202 - 209
  • [4] Determination of trace rare earth elements in soils by inductively coupled plasma-mass spectrometry after microwave digestion for sample preparation
    Cao, XD
    Yin, M
    Wang, XR
    Zhao, GW
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (06) : 679 - 683
  • [5] Determination of trace elements in agricultural soil samples by inductively coupled plasma-mass spectrometry: Microwave acid digestion versus aqua regia extraction
    Melaku, S
    Dams, R
    Moens, L
    ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) : 117 - 123
  • [6] Microwave assisted digestion of atmospheric aerosol samples followed by inductively coupled plasma mass spectrometry determination of trace elements
    Swami, K
    Judd, CD
    Orsini, J
    Yang, KX
    Husain, L
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (01): : 63 - 70
  • [7] Microwave assisted digestion of atmospheric aerosol samples followed by inductively coupled plasma mass spectrometry determination of trace elements
    K. Swami
    C. D. Judd
    J. Orsini
    K. X. Yang
    L. Husain
    Fresenius' Journal of Analytical Chemistry, 2001, 369 : 63 - 70
  • [8] Determination of minor and trace elements in aromatic spices by micro-wave assisted digestion and inductively coupled plasma-mass spectrometry
    Khan, Naeem
    Choi, Ji Yeon
    Nho, Eun Yeong
    Jamila, Nargis
    Habte, Girum
    Hong, Joon Ho
    Hwang, In Min
    Kim, Kyong Su
    FOOD CHEMISTRY, 2014, 158 : 200 - 206
  • [9] Determination of Trace Elements in Sulfide Samples by Inductively Coupled Plasma-Mass Spectrometry
    Yin Xue-Bo
    Zeng Zhi-Gang
    Li San-Zhong
    Wu Li
    Wang Xiao-Yuan
    Zhang Guo-Liang
    Chen Shuai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (08) : 1228 - 1232
  • [10] Determination of twenty-five elements in lichens by sector field inductively coupled plasma mass spectrometry and microwave-assisted acid digestion
    Pino, Anna
    Alimonti, Alessandro
    Botre, Francesco
    Minoia, Claudio
    Bocca, Beatrice
    Conti, Marcelo E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (12) : 1900 - 1906