The use of microwave-induced plasma optical emission spectrometry for fluorine determination and its application to tea infusions

被引:11
|
作者
Akhdhar, Abdullah [1 ,2 ]
Schneider, Mauana [1 ,3 ]
Hellmann, Steffen [1 ]
Orme, Alice [1 ]
Carasek, Eduardo [3 ]
Krupp, Eva M. [1 ]
Feldmann, Joerg [1 ,4 ]
机构
[1] Univ Aberdeen, Dept Chem, Trace Element Speciat Lab Aberdeen TESLA, Aberdeen AB24 3UE, Scotland
[2] Univ Jeddah, Coll Sci, Dept Chem, Jeddah, Saudi Arabia
[3] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[4] Karl Franzens Univ Graz, Inst Chem, TESLA Environm Analyt Chem, A-8010 Graz, Austria
关键词
Fluorine; CaF; MIP-OES; Emission spectrometry; Tea; HR-GF MAS; ELECTROTHERMAL VAPORIZATION; HUMAN EXPOSURE;
D O I
10.1016/j.talanta.2021.122190
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents a novel method for fluorine quantification determination by microwave-induced plasma optical emission spectrometry (MIP-OES). Due to the low temperature of this plasma, atomic emission of fluorine could not be measured, instead CaF molecular emissions were measured by using a calcium solution mixed in the spray chamber with the sample using a T-piece. Several wavelengths were studied to find the best signal to noise ratio for fluorine determination and 530.45 nm was chosen. The limit of detection for the determination of fluorine via CaF using MIP-OES was 1.1 mg L-1. A linear response was observed over two orders of magnitude (R-2 = 0.998). The developed method was applied to ten tea infusion samples from the UK and Saudi Arabia. The results were not significantly different (paired Student's t-test, p = 0.97) to the results obtained using the reference method, high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-GF MAS). The total fluorine in the tea infusions varied between 2.7 and 7.8 mg L-1; all of which were above the WHO recommended level of fluoride (0.8-1.5 mg L-1) in drinking water. This method can potentially be used for total fluorine determination and might be useful for fluorine speciation analysis when coupled with HPLC.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Coprecipitation magnesium(II) hydroxide as a strategy of pre-concentration for trace elemental determination by microwave-induced plasma optical emission spectrometry
    Moreira, Luana S.
    Sa, Ivero P.
    Machado, Raquel C.
    Nogueira, Ana Rita A.
    da Silva, Erik G. P.
    Amaral, Clarice D. B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 169
  • [42] SLURRY SAMPLE INTRODUCTION WITH MICROWAVE-INDUCED PLASMA ATOMIC EMISSION-SPECTROMETRY
    MATUSIEWICZ, H
    STURGEON, RE
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (05) : 723 - 727
  • [43] SPECIATION AT TRACE LEVELS BY HELIUM MICROWAVE-INDUCED PLASMA EMISSION-SPECTROMETRY
    BAUER, CF
    NATUSCH, DFS
    ANALYTICAL CHEMISTRY, 1981, 53 (13) : 2020 - 2027
  • [44] Characterization of solid particles by helium microwave-induced plasma atomic emission spectrometry
    Frame, EMS
    Takamatsu, Y
    Suzuki, T
    SPECTROSCOPY, 1996, 11 (01) : 17 - 22
  • [45] Determination of selenium concentrations in human blood plasma by microwave-induced plasma mass spectrometry
    Shinohara, A
    Chiba, M
    Inaba, Y
    ANALYTICAL SCIENCES, 1998, 14 (04) : 713 - 717
  • [46] Determination of Selenium Concentrations in Human Blood Plasma by Microwave-Induced Plasma Mass Spectrometry
    Atsuko Shinohara
    Momoko Chiba
    Yutaka Inaba
    Analytical Sciences, 1998, 14 : 713 - 717
  • [47] EMPIRICAL AND MOLECULAR FORMULA DETERMINATION BY GAS-CHROMATOGRAPHY MICROWAVE-INDUCED PLASMA ATOMIC EMISSION-SPECTROMETRY
    UDEN, PC
    SLATKAVITZ, KJ
    BARNES, RM
    DEMING, RL
    ANALYTICA CHIMICA ACTA, 1986, 180 : 401 - 416
  • [48] DETERMINATION OF MERCURY AT THE ULTRATRACE LEVEL BY ATMOSPHERIC-PRESSURE HELIUM MICROWAVE-INDUCED PLASMA EMISSION-SPECTROMETRY
    TANABE, K
    CHIBA, K
    HARAGUCHI, H
    FUWA, K
    ANALYTICAL CHEMISTRY, 1981, 53 (09) : 1450 - 1453
  • [49] Multi-energy calibration as a strategy for elemental analysis of fertilizers by microwave-induced plasma optical emission spectrometry
    Machado, Raquel C.
    Silva, Ana Beatriz S.
    Donati, George L.
    Nogueira, Ana Rita A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (07) : 1168 - 1172
  • [50] Signal correction using molecular species to improve biodiesel analysis by microwave-induced plasma optical emission spectrometry
    Lowery, Kenneth L.
    McSweeney, Tina
    Adhikari, Shiba P.
    Lachgar, Abdessadek
    Donati, George L.
    MICROCHEMICAL JOURNAL, 2016, 129 : 58 - 62