An 8-Channel RF Coil based on Microstrip Yagi-antenna for 7T Magnetic Resonance Imaging

被引:11
|
作者
He, Ke [1 ]
Yu, Mengxia [1 ]
Zhao, E. [1 ]
Li, Guiping [1 ]
Wang, Maoyan [1 ]
Ma, Jing [2 ]
机构
[1] Univ Elect Sci & Technol China UESTC, Sch Phys, Chengdu, Peoples R China
[2] Sci & Technol Special Syst Simulat Lab, Beijing, Peoples R China
关键词
RF coil; UHF; microstrip Yagi-antenna; MRI;
D O I
10.1109/IEEECONF35879.2020.9330174
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new RF coil based on microstrip Yagi-antenna for 7T magnetic resonance imaging (MRI) is presented in this paper. The RF coil element consists of a driver which is a pair of dipoles printed on the dielectric substrate and two reflectors distributed on either sides of the driver. Simulation results show that the proposed 8-channel RF coil array with these elements has high magnetic field intensity and uniform magnetic field distribution in the transverse plane, and can also maintain relatively low specific absorption rate (SAR) in the human body electromagnetic model. In addition, by comparing the RF field distribution of healthy organs and diseased organs, the feasibility of 8-channel RF coil array for human body imaging in MRI system is confirmed.
引用
收藏
页码:635 / 636
页数:2
相关论文
共 50 条
  • [21] MAGNETIC RESONANCE IMAGING OF THE CANINE BRAIN AT 3 AND 7T
    Martin-Vaquero, Paula
    da Costa, Ronaldo C.
    Echandi, Rita L.
    Tosti, Christina L.
    Knopp, Michael V.
    Sammet, Steffen
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (01) : 25 - 32
  • [22] A 16-Channel 13C Array Coil for Magnetic Resonance Spectroscopy of the Breast at 7T
    Wilcox, Matthew
    Ogier, Stephen
    Cheshkov, Sergey
    Dimitrov, Ivan
    Malloy, Craig
    Wright, Steven
    McDougall, Mary
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (06) : 2036 - 2046
  • [23] Circuitry Design and Magnetic Susceptibility Evaluation of 7T fMRI Implantable RF Coil
    Wang, Rong
    Dong, Celia M.
    Wu, Ed X.
    Roberts, Robert C.
    Jiang, Li Jun
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2018, 33 (10): : 1109 - 1111
  • [24] Comparison of an 8-Channel and a 32-Channel Coil for High-Resolution fMRI at 7 T
    Roy Salomon
    Jana Darulova
    Mayur Narsude
    Wietske van der Zwaag
    Brain Topography, 2014, 27 : 209 - 212
  • [25] Comparison of an 8-Channel and a 32-Channel Coil for High-Resolution fMRI at 7 T
    Salomon, Roy
    Darulova, Jana
    Narsude, Mayur
    van der Zwaag, Wietske
    BRAIN TOPOGRAPHY, 2014, 27 (02) : 209 - 212
  • [26] Circuitry Design and Magnetic Susceptibility Evaluation of 7T fMRI Implantable RF Coil
    Wang, Rong
    Dong, Celia M.
    Wu, Ed X.
    Roberts, Robert C.
    Jiang, Li Jun
    2018 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2018,
  • [27] A Compact and Efficient Multi-mode Antenna for Parallel Transmission of 7T Magnetic Resonance Imaging
    Pittman, Sam
    Hu, Bobo
    2013 LOUGHBOROUGH ANTENNAS AND PROPAGATION CONFERENCE (LAPC), 2013, : 534 - 538
  • [28] Feasibility Study for a Microstrip Transmission Line RF Coil Integrated with a PET Detector Module in a 7T Human MR Imaging System
    Akram, Md Shahadat Hossain
    Fukunaga, Masaki
    Nishikido, Fumihiko
    Takyu, Sodai
    Obata, Takayuki
    Yamaya, Taiga
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024,
  • [29] Comprehensive Study on Coupled Meandered Microstrip line RF Coil Elements for 7-Tesla Magnetic Resonance Imaging
    Abuelhaija, Ashraf
    Solbach, Klaus
    Orzada, Stephan
    2015 9th European Conference on Antennas and Propagation (EuCAP), 2015,
  • [30] Design and Application of Combined 8-Channel Transmit and 10-Channel Receive Arrays and Radiofrequency Shimming for 7-T Shoulder Magnetic Resonance Imaging
    Brown, Ryan
    Deniz, Cem Murat
    Zhang, Bei
    Chang, Gregory
    Sodickson, Daniel K.
    Wiggins, Graham C.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (01) : 35 - 47