An 8-Channel RF Coil based on Microstrip Yagi-antenna for 7T Magnetic Resonance Imaging

被引:11
|
作者
He, Ke [1 ]
Yu, Mengxia [1 ]
Zhao, E. [1 ]
Li, Guiping [1 ]
Wang, Maoyan [1 ]
Ma, Jing [2 ]
机构
[1] Univ Elect Sci & Technol China UESTC, Sch Phys, Chengdu, Peoples R China
[2] Sci & Technol Special Syst Simulat Lab, Beijing, Peoples R China
关键词
RF coil; UHF; microstrip Yagi-antenna; MRI;
D O I
10.1109/IEEECONF35879.2020.9330174
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new RF coil based on microstrip Yagi-antenna for 7T magnetic resonance imaging (MRI) is presented in this paper. The RF coil element consists of a driver which is a pair of dipoles printed on the dielectric substrate and two reflectors distributed on either sides of the driver. Simulation results show that the proposed 8-channel RF coil array with these elements has high magnetic field intensity and uniform magnetic field distribution in the transverse plane, and can also maintain relatively low specific absorption rate (SAR) in the human body electromagnetic model. In addition, by comparing the RF field distribution of healthy organs and diseased organs, the feasibility of 8-channel RF coil array for human body imaging in MRI system is confirmed.
引用
收藏
页码:635 / 636
页数:2
相关论文
共 50 条
  • [11] Microaneurysm Diagnosed With 7T Magnetic Resonance Imaging
    Wang, Linlin
    Zhang, Yingkui
    Sui, Binbin
    Zhao, Xingquan
    Ji, Ruijun
    STROKE, 2022, 53 (06) : E224 - E225
  • [12] A combined 32-channel receive-loops/8-channel transmit-dipoles coil array for whole-brain MR imaging at 7T
    Clement, Jeremie
    Gruetter, Rolf
    Ipek, Ozlem
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1229 - 1241
  • [13] An open 8-channel parallel transmission coil for static and dynamic 7T MRI of the knee and ankle joints at multiple postures
    Jin, Jin
    Weber, Ewald
    Destruel, Aurelien
    O'Brien, Kieran
    Henin, Bassem
    Engstrom, Craig
    Crozier, Stuart
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1804 - 1816
  • [14] An 8-channel Phased Array for Carotid Artery Magnetic Resonance Imaging at 3T
    Luo, Chao
    Hu, Xiaoqing
    Chen, Xiao
    Zhang, Lei
    Liu, Shengping
    Liu, Xin
    Zheng, Hairong
    Li, Ye
    2015 ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), VOLS 1-3, 2015,
  • [15] Global Maxwell Tomography using an 8-channel radiofrequency coil: simulation results for a tissue-mimicking phantom at 7T
    Giannakopoulos, Ilias I.
    Serralles, Jose E. C.
    Zhang, Bei
    Daniel, Luca
    White, Jacob K.
    Lattanzi, Riccardo
    2019 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND USNC-URSI RADIO SCIENCE MEETING, 2019, : 823 - 824
  • [16] A new RF transmit coil for foot and ankle imaging at 7T MRI
    Santini, Tales
    Kim, Junghwan
    Wood, Sossena
    Krishnamurthy, Narayanan
    Farhat, Nadim
    Maciel, Carlos
    Raval, Shailesh
    Zhao, Tiejun
    Ibrahim, Tamer S.
    MAGNETIC RESONANCE IMAGING, 2018, 45 : 1 - 6
  • [17] A CRLH Metamaterial based RF Coil Element for Magnetic Resonance Imaging at 7 Tesla
    Rennings, A.
    Mosig, J.
    Bahr, A.
    Caloz, C.
    Ladd, M. E.
    Erni, D.
    2009 3RD EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, VOLS 1-6, 2009, : 3115 - +
  • [18] High-resolution volumetric dynamic magnetic resonance imaging of the wrist using an 8-channel flexible receive coil
    Zi, Ruoxun
    Abbas, Batool
    Wang, Bili
    Walczyk, Jerzy
    Brown, Ryan
    Petchprapa, Catherine
    Fishbaugh, James
    Gerig, Guido
    Block, Kai Tobias
    Lattanzi, Riccardo
    SKELETAL RADIOLOGY, 2024, : 1291 - 1299
  • [19] Design and construction of an 8-channel transceiver coil array for rat imaging at 9.4 T
    Du, Feng
    Li, Nan
    Yang, Xing
    Zhang, Baogui
    Zhang, Xiaoliang
    Li, Ye
    JOURNAL OF MAGNETIC RESONANCE, 2023, 351
  • [20] In vivo magnetic resonance imaging of spinal cord at 7T
    Elshafiey, I
    Narayana, PA
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 21A & B, 2002, 615 : 1850 - 1857