A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments

被引:10
|
作者
Hynynen, K. [1 ]
Roemer, R. [1 ,2 ]
Anhalt, D. [3 ]
Johnson, C. [3 ]
Xu, Z. X. [2 ]
Swindell, W. [1 ]
Cetas, T. [1 ]
机构
[1] Univ Arizona, Arizona Hlth Sci Ctr, Dept Radiat Oncol, Tucson, AZ 85724 USA
[2] Univ Arizona, Dept Aerosp & Mech Engn, Tucson, AZ 85721 USA
[3] Univ Arizona, Dept Elect & Comp Engn, Tucson, AZ 85721 USA
关键词
hyperthermia; ultrasound; focused fields; temperature distribution; deep heating; DISTRIBUTIONS; TEMPERATURE; PROBES;
D O I
10.3109/02656730903492916
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A commercial diagnostic ultrasound scanner (Octoson) was modified for performing hyperthermia treatments. The temperature elevations were induced in tissues by four large, focused ultrasonic transducers whose common focal zone was scanned along a computer controlled path as determined from B-scan images. The system is described and the results of preliminary tests demonstrating some of its capabilities are given. Extensive tests with canine thighs and kidneys were performed. The blood flow to the kidneys was controllable, and thus tumours having different blood perfusion rates could be simulated. The results showed that the system is capable of inducing a local temperature maximum deep in tissues (up to 10 cm was tested) and that tissues with high perfusion rates could be heated.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [31] Investigation of a scanned cylindrical ultrasound system for breast hyperthermia
    Ju, KC
    Tseng, LT
    Chen, YY
    Lin, WL
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03): : 539 - 555
  • [32] Boundary diffraction wave model for a spherically focused ultrasonic transducer
    Schmerr, LW
    Sedov, A
    Lerch, TP
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (03): : 1269 - 1277
  • [33] Non linear parametric imaging using an ultrasonic focused transducer
    Robin, Guillaume
    Vander Meulen, Francois
    Fortineau, Jerome
    Feuillard, Guy
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1080 - 1083
  • [34] Effect of radial displacement of lens on response of focused ultrasonic transducer
    Marechal, Pierre
    Levassort, Franck
    Tran-Huu-Hue, Louis-Pascal
    Lethiecq, Marc
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (5A): : 3077 - 3085
  • [35] LOCAL HYPERTHERMIA INDUCED BY AN ARRAY OF FOCUSED ULTRASONIC TRANSDUCERS INVIVO
    HYNYNEN, K
    WATMOUGH, DJ
    MALLARD, JR
    FULLER, M
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (01): : 101 - 101
  • [36] Focused intravascular ultrasonic probe using dimpled transducer elements
    Chen, Y.
    Qiu, W. B.
    Lam, K. H.
    Liu, B. Q.
    Jiang, X. P.
    Zheng, H. R.
    Luo, H. S.
    Chan, H. L. W.
    Dai, J. Y.
    ULTRASONICS, 2015, 56 : 227 - 231
  • [37] Focused high frequency needle transducer for ultrasonic imaging and trapping
    Hsu, Hsiu-Sheng
    Zheng, Fan
    Li, Ying
    Lee, Changyang
    Zhou, Qifa
    Shung, K. Kirk
    APPLIED PHYSICS LETTERS, 2012, 101 (02)
  • [38] Transcranial propagation with an ultrasonic mono-element focused transducer
    Iglesias, P. C.
    Jimenez, N.
    Konofagou, E.
    Camarena, F.
    Redondo, J.
    43RD ANNUAL UIA SYMPOSIUM, 2015, 63 : 103 - 107
  • [39] Endoscopic therapeutic device using focused ultrasonic small transducer
    Yasui, Akihiro
    Haga, Yoichi
    Chen, Jiun-Jie
    Iseki, Hiroshi
    Esashi, Masayoshi
    Wada, Hiroshi
    IEEJ Transactions on Sensors and Micromachines, 2007, 127 (02) : 69 - 74
  • [40] Electrical Tuning of Focal Size with Single Focused Ultrasonic Transducer
    Tang, Yongkui
    Kim, Eun Sok
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,