Feasibility and accuracy of fusion imaging during thoracic endovascular aortic repair

被引:28
|
作者
Schulz, Christof Johannes [1 ]
Schmitt, Matthias [1 ]
Boeckler, Dittmar [1 ]
Geisbuesch, Philipp [1 ]
机构
[1] Univ Heidelberg Hosp, Dept Vasc & Endovasc Surg, Heidelberg, Germany
关键词
ANEURYSM REPAIR; SYSTEM;
D O I
10.1016/j.jvs.2015.08.089
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To evaluate accuracy and feasibility of fusion imaging during thoracic endovascular aortic repair (TEVAR). Methods: From January 2013 to January 2015 fusion imaging was used in 18 TEVAR procedures. Patients were prospectively enrolled for the survey and informed consent was obtained. Planning of the procedure and computed tomography (CT) angiography (CTA) segmentation with determination of all relevant surgical landmarks that should be displayed on fusion imaging was done using the preoperative CTA data. The registration was done with an intraoperative noncontrast-enhanced cone beam CT and CTA (three-dimensional [3D]-3D registration; n = 15) or with two fluoroscopic images in anteroposterior and lateral projection and the CTA (two-dimensional-3D registration; n = 3). An intraoperative digital subtraction angiography was performed to adjust fusion imaging and to allow accuracy measurement. Results: Fusion imaging was possible in all included patients. The median dose for noncontrast-enhanced cone beam CT imaging was 28.6 Gy/cm(2) (range, 17.9-43.3) and 0.46 Gy cm(2) for two fluoroscopic images in the two-dimensional-3D group. Full accuracy was achieved in two cases (11%), with a median deviation of 11.7 mm (range, 0.0-37.2). Manual realignment was possible in all cases. Conclusions: This early experience shows that fusion imaging is feasible in TEVAR procedures using different registration methods. However, it shows a significant deviation in thoracic procedures because of different sources of error, making confirmation of fusion overlay with a digital subtraction angiography necessary in any case.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 50 条
  • [1] Feasibility of Concurrent Thoracic and Abdominal Aortic Endovascular Repair
    Khan, Muhammad Asad
    Singh, Kuldeep
    Schor, Jonathan
    Deitch, Jonathan
    JOURNAL OF VASCULAR SURGERY, 2012, 56 (03) : 886 - 886
  • [2] Feasibility of three-dimensional fusion imaging with multimodality roadmap system during endovascular aortic repair
    Hiraoka, Arudo
    Shiraya, Suguru
    Chikazawa, Genta
    Ishida, Atsuhisa
    Miyake, Koichi
    Sakaguchi, Taichi
    Yoshitaka, Hidenori
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (04) : 1175 - 1182
  • [3] Automated image fusion during endovascular aneurysm repair: a feasibility and accuracy study
    Smorenburg, Stefan P. M.
    Lely, Rutger J.
    Smit-Ockeloen, Iris
    Yeung, Kak Khee
    Hoksbergen, Arjan W. J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (08) : 1533 - 1541
  • [4] Automated image fusion during endovascular aneurysm repair: a feasibility and accuracy study
    Stefan P. M. Smorenburg
    Rutger J. Lely
    Iris Smit-Ockeloen
    Kak Khee Yeung
    Arjan W. J. Hoksbergen
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 (8) : 1533 - 1541
  • [5] Cardiac tamponade during thoracic endovascular aortic repair
    Bousselmi, Radhouane
    Lebbi, Anis
    Chaouech, Nazih
    Ferjani, Mustapha
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2014, 19 (06): : 571 - 573
  • [6] Endovascular Aortic Repair for Thoracic Aortic Injuries
    Ehsan, Omer
    Choudry, Usama Khalid
    Rana, Atif
    Khan, Zahid Amin
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2018, 28 (09): : S178 - S180
  • [7] Aortic disease: thoracic endovascular aortic repair
    Bicknell, Colin
    Powell, Janet T.
    HEART, 2015, 101 (08) : 586 - 591
  • [8] Severe Tortuosity of the Distal Descending Thoracic Aorta Affects the Accuracy of Distal Deployment During a Thoracic Endovascular Aortic Repair
    Sato, Tomohiro
    Banno, Hiroshi
    Ikeda, Shuta
    Kawai, Yohei
    Tsuruoka, Takuya
    Sugimoto, Masayuki
    Niimi, Kiyoaki
    Kodama, Akio
    Komori, Kimihiro
    JOURNAL OF ENDOVASCULAR THERAPY, 2024, 31 (04) : 706 - 712
  • [9] Thoracic Endovascular Aortic Repair in “Shaggy Thoracic Aortic Aneurysms”
    Marco Franchin
    Viviana Grassi
    Gabriele Piffaretti
    Ruth L. Bush
    Matteo Tozzi
    Chiara Lomazzi
    CardioVascular and Interventional Radiology, 2021, 44 : 220 - 229
  • [10] Thoracic Endovascular Aortic Repair in "Shaggy Thoracic Aortic Aneurysms"
    Franchin, Marco
    Grassi, Viviana
    Piffaretti, Gabriele
    Bush, Ruth L.
    Tozzi, Matteo
    Lomazzi, Chiara
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (02) : 220 - 229