Feasibility and accuracy of fusion imaging during thoracic endovascular aortic repair

被引:28
|
作者
Schulz, Christof Johannes [1 ]
Schmitt, Matthias [1 ]
Boeckler, Dittmar [1 ]
Geisbuesch, Philipp [1 ]
机构
[1] Univ Heidelberg Hosp, Dept Vasc & Endovasc Surg, Heidelberg, Germany
关键词
ANEURYSM REPAIR; SYSTEM;
D O I
10.1016/j.jvs.2015.08.089
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To evaluate accuracy and feasibility of fusion imaging during thoracic endovascular aortic repair (TEVAR). Methods: From January 2013 to January 2015 fusion imaging was used in 18 TEVAR procedures. Patients were prospectively enrolled for the survey and informed consent was obtained. Planning of the procedure and computed tomography (CT) angiography (CTA) segmentation with determination of all relevant surgical landmarks that should be displayed on fusion imaging was done using the preoperative CTA data. The registration was done with an intraoperative noncontrast-enhanced cone beam CT and CTA (three-dimensional [3D]-3D registration; n = 15) or with two fluoroscopic images in anteroposterior and lateral projection and the CTA (two-dimensional-3D registration; n = 3). An intraoperative digital subtraction angiography was performed to adjust fusion imaging and to allow accuracy measurement. Results: Fusion imaging was possible in all included patients. The median dose for noncontrast-enhanced cone beam CT imaging was 28.6 Gy/cm(2) (range, 17.9-43.3) and 0.46 Gy cm(2) for two fluoroscopic images in the two-dimensional-3D group. Full accuracy was achieved in two cases (11%), with a median deviation of 11.7 mm (range, 0.0-37.2). Manual realignment was possible in all cases. Conclusions: This early experience shows that fusion imaging is feasible in TEVAR procedures using different registration methods. However, it shows a significant deviation in thoracic procedures because of different sources of error, making confirmation of fusion overlay with a digital subtraction angiography necessary in any case.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 50 条
  • [21] Complications of endovascular repair for thoracic and abdominal aortic aneurysm: An imaging spectrum
    Mita, T
    Arita, T
    Matsunaga, N
    Furukawa, M
    Zempo, N
    Esato, K
    Matsuzaki, M
    RADIOGRAPHICS, 2000, 20 (05) : 1263 - 1278
  • [22] Limitation of Imaging in Identifying Iatrogenic Aortic Coarctation following Thoracic Endovascular Aortic Repair
    Thakkar, Rajiv N.
    Thomaier, Lauren
    Qazi, Umair
    Verde, Franco
    Malas, Mahmoud B.
    ANNALS OF VASCULAR SURGERY, 2015, 29 (03) : 594.e11 - 594.e16
  • [23] Zero-Contrast Thoracic Endovascular Aortic Repair Using Image Fusion
    Kobeiter, Hicham
    Nahum, Julien
    Becquemin, Jean-Pierre
    CIRCULATION, 2011, 124 (11) : E280 - E282
  • [24] Timing of repair of blunt thoracic aortic injuries in the thoracic endovascular aortic repair era
    Alarhayem, Abdul Q.
    Rasmussen, Todd E.
    Farivar, Behzad
    Lim, Sungho
    Braverman, Max
    Hardy, David
    Jenkins, Donald J.
    Eastridge, Brian J.
    Cestero, Ramon F.
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (03) : 896 - 902
  • [25] Effectiveness of Thoracic Endovascular Aortic Repair for Blunt Thoracic Aortic Injury
    Okadome, Jun
    Morishige, Noritsugu
    Sukehiro, Yuta
    Norio, Hirofumi
    Maetani, Kazuhide
    Yanase, Go
    Ito, Hiroyuki
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 29 (03) : 133 - 140
  • [26] Thoracic Endovascular Aortic Repair for Ruptured Descending Thoracic Aortic Aneurysm
    Minami, Tomoyuki
    Imoto, Kiyotaka
    Uchida, Keiji
    Karube, Norihisa
    Yasuda, Shota
    Choh, Tomoki
    Suzuki, Shinichi
    Masuda, Munetaka
    JOURNAL OF CARDIAC SURGERY, 2015, 30 (02) : 163 - 169
  • [27] Thoracic endovascular aortic repair of an ascending aortic pseudoaneurysm
    Uchino, Motonori
    Fumoto, Hideyuki
    Yunoki, Junji
    Nakayama, Yoshihiro
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2023, 31 (05): : 439 - 441
  • [28] Thoracic Endovascular Aortic Repair for Penetrating Aortic Trauma
    Zambetti, Benjamin R.
    Plant, Joshua
    Zhang, Jackie M.
    Ghoreishi, Mehrdad
    Toursavadkohi, Shahab
    ANNALS OF VASCULAR SURGERY, 2025, 113 : 35 - 40
  • [29] Evaluation of Aortic Zone 2 Landing Accuracy During Thoracic Endovascular Aortic Repair Following Carotid-Subclavian Revascularization
    Choi, Sally H. J.
    Yang, Gary K.
    Baxter, Keith
    Gagnon, Joel
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (04) : E98 - E99
  • [30] Thoracic endovascular aortic repair for an ascending aortic pseudoaneurysm
    Takago, Shintaro
    Kato, Hiroki
    Yamamoto, Yoshitaka
    Iino, Kenji
    Kimura, Keiichi
    Takemura, Hirofumi
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2020, 28 (06): : 330 - 332