Automated image fusion during endovascular aneurysm repair: a feasibility and accuracy study

被引:2
|
作者
Smorenburg, Stefan P. M. [1 ,3 ]
Lely, Rutger J. [2 ,3 ]
Smit-Ockeloen, Iris [4 ]
Yeung, Kak Khee [1 ,3 ]
Hoksbergen, Arjan W. J. [1 ,3 ]
机构
[1] Vrije Univ, Amsterdam Univ Med Ctr, Dept Surg, Room J1A-222,Postbox 22660, NL-1100 DD Amsterdam, Netherlands
[2] Vrije Univ, Amsterdam Univ Med Ctr, Dept Radiol, Amsterdam, Netherlands
[3] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[4] Philips, Dept Image Guided Therapy, Best, Netherlands
关键词
Image fusion; Fusion imaging; 2D-3D; Automated; 3D roadmap; EVAR; Navigation; Overlay; DECREASES RADIATION-EXPOSURE; CONTRAST AGENT; PROCEDURE TIME; FLUOROSCOPY; REGISTRATION; ANGIOGRAPHY; DEFORMATIONS; GUIDANCE; EVAR;
D O I
10.1007/s11548-023-02832-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Image fusion merges preoperative computed tomography angiography (CTA) with live fluoroscopy during endovascular procedures to function as an overlay 3D roadmap. However, in most current systems, the registration between imaging modalities is performed manually by vertebral column matching which can be subjective, inaccurate and time consuming depending on experience. Our objective was to evaluate feasibility and accuracy of image-based automated 2D-3D image fusion between preoperative CTA and intraoperative fluoroscopy based on vertebral column matching. Methods A single-center study with offline procedure data was conducted in 10 consecutive patients which had endovascular aortic repair in which we evaluated unreleased automated fusion software provided by Philips (Best, the Netherlands). Fluoroscopy and digital subtraction angiography images were collected after the procedures and the vertebral column was fused fully automatically. Primary endpoints were feasibility and accuracy of bone alignment (mm). Secondary endpoint was vascular alignment (mm) between the lowest renal artery orifices. Clinical non-inferiority was defined at a mismatch of < 1 mm. Results In total, 87 automated measurements and 40 manual measurements were performed on vertebrae T12-L5 in all 10 patients. Manual correction was needed in 3 of the 10 patients due to incomplete visibility of the vertebral edges in the fluoroscopy image. Median difference between automated fusion and manual fusion was 0.1 mm for bone alignment (p = 0.94). The vascular alignment was 4.9 mm (0.7-17.5 mm) for manual and 5.5 mm (1.0-14.0 mm) for automated fusion. This did not improve, due to the presence of stiff wires and stent graft. Conclusion Automated image fusion was feasible when all vertebral edges were visible. Accuracy was non-inferior to manual image fusion regarding bone alignment. Future developments should focus on intraoperative image-based correction of vascular alignment.
引用
收藏
页码:1533 / 1541
页数:9
相关论文
共 50 条
  • [1] Automated image fusion during endovascular aneurysm repair: a feasibility and accuracy study
    Stefan P. M. Smorenburg
    Rutger J. Lely
    Iris Smit-Ockeloen
    Kak Khee Yeung
    Arjan W. J. Hoksbergen
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 (8) : 1533 - 1541
  • [2] Feasibility and accuracy of fusion imaging during thoracic endovascular aortic repair
    Schulz, Christof Johannes
    Schmitt, Matthias
    Boeckler, Dittmar
    Geisbuesch, Philipp
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (02) : 314 - 322
  • [3] Impact of calcification modeling to improve image fusion accuracy for endovascular aortic aneurysm repair
    McLennan, Stewart
    Soulez, Gilles
    Mongrain, Rosaire
    Mohammadi, Hossein
    Pfister, Marcus
    Lessard, Simon
    Jabbour, Gilbert
    Therasse, Eric
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2022, 38 (02)
  • [4] Image Optimization During Endovascular Aneurysm Repair
    Walker, T. Gregory
    Kalva, Sanjeeva P.
    Ganguli, Suvranu
    Oeklue, Rahmi
    Salazar, Gloria M.
    Waltman, Arthur C.
    Wicky, Stephan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 200 - 206
  • [5] Feasibility of Three-Dimensional MR Angiography Image Fusion Guidance for Endovascular Abdominal Aortic Aneurysm Repair
    Tacher, Vania
    Desgranges, Pascal
    You, Ketsakin
    Ridouani, Fourat
    Marzelle, Jean
    Kobeiter, Hicham
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (02) : 188 - 193
  • [6] CTA with Fluoroscopy Image Fusion Guidance in Endovascular Complex Aortic Aneurysm Repair
    Sailer, A. M.
    de Haan, M. W.
    Peppelenbosch, A. G.
    Jacobs, M. J.
    Wildberger, J. E.
    Schurink, G. W. H.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (04) : 349 - 356
  • [7] Feasibility and Cost Analysis of Ambulatory Endovascular Aneurysm Repair
    Naiem, Ahmed A. A.
    Doonan, R. J.
    Guigui, Andre
    Obrand, Daniel I. I.
    Bayne, Jason P. P.
    MacKenzie, Kent S. S.
    Steinmetz, Oren K. K.
    Girsowicz, Elie
    Gill, Heather L. L.
    JOURNAL OF ENDOVASCULAR THERAPY, 2024, 31 (04) : 576 - 583
  • [8] Aortic aneurysm sac filling with AneuFix injectable polymer during endovascular aneurysm repair: feasibility and safety trial study protocol
    Smorenburg, Stefan P. M.
    Lely, Rutger J.
    Jacobs, Michael J.
    Hoksbergen, Arjan W. J.
    BMJ OPEN, 2024, 14 (07): : 1 - 6
  • [9] Remote ischemic preconditioning for elective endovascular intracranial aneurysm repair: a feasibility study
    Seyedsaadat, Seyed Mohammad
    Castilla, Leonardo Rangel
    Lanzino, Giuseppe
    Cloft, Harry J.
    Blezek, Daniel J.
    Theiler, Amy
    Kadirvel, Ramanathan
    Brinjikji, Waleed
    Kallmes, David F.
    NEURORADIOLOGY JOURNAL, 2019, 32 (03): : 166 - 172
  • [10] Endovascular management of iliac rupture during endovascular aneurysm repair
    Fernandez, Joss D.
    Craig, John M.
    Garrett, H. Edward, Jr.
    Burgar, Suzanne R.
    Bush, Andrew J.
    JOURNAL OF VASCULAR SURGERY, 2009, 50 (06) : 1293 - 1300