Automated image fusion during endovascular aneurysm repair: a feasibility and accuracy study

被引:2
|
作者
Smorenburg, Stefan P. M. [1 ,3 ]
Lely, Rutger J. [2 ,3 ]
Smit-Ockeloen, Iris [4 ]
Yeung, Kak Khee [1 ,3 ]
Hoksbergen, Arjan W. J. [1 ,3 ]
机构
[1] Vrije Univ, Amsterdam Univ Med Ctr, Dept Surg, Room J1A-222,Postbox 22660, NL-1100 DD Amsterdam, Netherlands
[2] Vrije Univ, Amsterdam Univ Med Ctr, Dept Radiol, Amsterdam, Netherlands
[3] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[4] Philips, Dept Image Guided Therapy, Best, Netherlands
关键词
Image fusion; Fusion imaging; 2D-3D; Automated; 3D roadmap; EVAR; Navigation; Overlay; DECREASES RADIATION-EXPOSURE; CONTRAST AGENT; PROCEDURE TIME; FLUOROSCOPY; REGISTRATION; ANGIOGRAPHY; DEFORMATIONS; GUIDANCE; EVAR;
D O I
10.1007/s11548-023-02832-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Image fusion merges preoperative computed tomography angiography (CTA) with live fluoroscopy during endovascular procedures to function as an overlay 3D roadmap. However, in most current systems, the registration between imaging modalities is performed manually by vertebral column matching which can be subjective, inaccurate and time consuming depending on experience. Our objective was to evaluate feasibility and accuracy of image-based automated 2D-3D image fusion between preoperative CTA and intraoperative fluoroscopy based on vertebral column matching. Methods A single-center study with offline procedure data was conducted in 10 consecutive patients which had endovascular aortic repair in which we evaluated unreleased automated fusion software provided by Philips (Best, the Netherlands). Fluoroscopy and digital subtraction angiography images were collected after the procedures and the vertebral column was fused fully automatically. Primary endpoints were feasibility and accuracy of bone alignment (mm). Secondary endpoint was vascular alignment (mm) between the lowest renal artery orifices. Clinical non-inferiority was defined at a mismatch of < 1 mm. Results In total, 87 automated measurements and 40 manual measurements were performed on vertebrae T12-L5 in all 10 patients. Manual correction was needed in 3 of the 10 patients due to incomplete visibility of the vertebral edges in the fluoroscopy image. Median difference between automated fusion and manual fusion was 0.1 mm for bone alignment (p = 0.94). The vascular alignment was 4.9 mm (0.7-17.5 mm) for manual and 5.5 mm (1.0-14.0 mm) for automated fusion. This did not improve, due to the presence of stiff wires and stent graft. Conclusion Automated image fusion was feasible when all vertebral edges were visible. Accuracy was non-inferior to manual image fusion regarding bone alignment. Future developments should focus on intraoperative image-based correction of vascular alignment.
引用
收藏
页码:1533 / 1541
页数:9
相关论文
共 50 条
  • [31] Endovascular Aortic Aneurysm Repair With a CO2 Automated System
    Faggioli, Gianluca
    Vacirca, Andrea
    Mascoli, Chiara
    Vento, Vincenzo
    Gallitto, Enrico
    Indelicato, Giuseppe
    Gargiulo, Mauro
    Stella, Andrea
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) : 206S - 206S
  • [32] Management of Difficult Access during Endovascular Aneurysm Repair
    Etkin, Yana
    Baig, Asad
    Foley, Paul J.
    Wang, Grace J.
    Woo, Edward Y.
    Carpenter, Jeffrey P.
    Fairman, Ronald M.
    Jackson, Benjamin M.
    ANNALS OF VASCULAR SURGERY, 2017, 44 : 77 - 82
  • [33] Automated Multi-View Planning for Endovascular Aneurysm Repair Procedures
    Zhang, Baochang
    Liu, Yiwen
    Liu, Shuting
    Schunkert, Heribert
    Ghotbi, Reza
    Navab, Nassir
    CLINICAL IMAGE-BASED PROCEDURES, CLIP 2024, 2024, 15196 : 22 - 31
  • [34] Standardization of a Carbon Dioxide Automated System for Endovascular Aortic Aneurysm Repair
    Mascoli, Chiara
    Faggioli, Gianluca
    Gallitto, Enrico
    Vento, Vincenzo
    Pini, Rodolfo
    Vacirca, Andrea
    Indelicato, Giuseppe
    Gargiulo, Mauro
    Stella, Andrea
    ANNALS OF VASCULAR SURGERY, 2018, 51 : 160 - 169
  • [35] Accuracy and Utility of Intravascular Ultrasound for Fenestrated Endovascular Aortic Aneurysm Repair
    Knowles, Martyn
    Stanley, Gregory A.
    Baig, Mirza S.
    Valentine, Rawson J.
    Timaran, Carlos H.
    JOURNAL OF VASCULAR SURGERY, 2013, 58 (04) : 1157 - 1157
  • [36] Source of Errors and Accuracy of a Two-Dimensional/Three-Dimensional Fusion Road Map for Endovascular Aneurysm Repair of Abdominal Aortic Aneurysm
    Kauffmann, Claude
    Douane, Frederic
    Therasse, Eric
    Lessard, Simon
    Elkouri, Stephane
    Gilbert, Patrick
    Beaudoin, Nathalie
    Pfister, Marcus
    Blair, Jean Francois
    Soulez, Gilles
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (04) : 544 - 551
  • [37] Computed tomography angiography-fluoroscopy image fusion allows visceral vessel cannulation without angiography during fenestrated endovascular aneurysm repair
    Schwein, Adeline
    Chinnadurai, Ponraj
    Behler, Greg
    Lumsden, Alan B.
    Bismuth, Jean
    Bechara, Carlos F.
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (01) : 2 - 11
  • [38] Cloud-based fusion imaging improves operative metrics during fenestrated endovascular aneurysm repair
    Bailey, Charles J.
    Edwards, Jeffrey B.
    Giarelli, Marcelo
    Zwiebel, Bruce
    Grundy, Laurence
    Shames, Murray
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (02) : 366 - 373
  • [39] Cloud-based Fusion Imaging Improves Operative Metrics During Fenestrated Endovascular Aneurysm Repair
    Bailey, Charles J.
    Edwards, Jeffrey B.
    Giarelli, Marcelo J.
    Zweibel, Bruce J.
    Grundy, Laurence J.
    Shames, Murray J.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (01) : E33 - E33
  • [40] Endovascular repair of ruptured abdominal aortic aneurysm:: Feasibility and impact on early outcome
    Brandt, M
    Walluscheck, KP
    Jahnke, T
    Graw, K
    Cremer, J
    Müller-Hülsbeck, S
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (10) : 1309 - 1312