Estimation of HVL in computed tomography using CTDI measurements

被引:0
|
作者
Yang, Z. [1 ]
Chu, R. [1 ]
Ruan, C. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK USA
关键词
D O I
10.1118/1.2760387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the HVL of CT systems from CTDI dosimetry measurements without additional test, and to overcome the technical difficulties in CT HVL measurements. Method and Materials: The HVL of one multi‐detector CT scanner was measured when the scanner is static, over the available energy range (80∼140 kVp) and with different bow‐tie filter configurations. Commercial CT dose phantoms in compliance with FDA specifications were used to measure the exposures. Nine doses at the central, peripheral, and intermediate positions were measured for both head and body phantoms. Averages were taken for doses measured at axially symmetric positions of each phantom. These averages were compared to the central position dose measurements. The ratios were analyzed along with the HVL values measured under exactly the same conditions and fitted to second power polynomials. Combining the fitting parameters and dosimetry measurements from different machines, the corresponding HVL were predicted and compared to the measured value of each machine. Results: The HVL of the CT scanner were determined to be between 5 to 10 mm Al over the energy range assessed. When the values were plotted against the dose at the peripheral or intermediate position, normalized by center dose, the curves all fit to second power polynomials with R2>0.99. When applying the correlation obtained from the fittings to dosimetry measurements from different machines, the calculated HVLs are within 5% or 0.5 mm Al error of the measured values. Conclusion: This study showed that the data collected for the CTDI measurements can be directly used to estimate the HVL of CT scanners to certain accuracy. This will reduce the time and effort needed for medical physicists to determine the HVL of CT systems during acceptance testing and annual quality assurance surveys. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2340 / 2340
页数:1
相关论文
共 50 条
  • [41] Computed tomography with view angle estimation using uncertainty quantification
    Brogaard Riis, Nicolai Andre
    Dong, Yiqiu
    Hansen, Per Christian
    INVERSE PROBLEMS, 2021, 37 (06)
  • [42] Forensic age estimation of adolescents using computed tomography of the clavicles
    Vamberszky, Leonie
    Uhl, Markus
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2024, 138 (06) : 2381 - 2386
  • [43] The estimation of coronary artery calcium thickness by computed tomography angiography based on optical coherence tomography measurements
    Masaaki Okutsu
    Satoru Mitomo
    Hirokazu Onishi
    Akihiro Nakajima
    Hiroto Yabushita
    Satoshi Matsuoka
    Hiroyoshi Kawamoto
    Yusuke Watanabe
    Kentaro Tanaka
    Toru Naganuma
    Satoko Tahara
    Shotaro Nakamura
    Sandeep Basavarajaiah
    Sunao Nakamura
    Heart and Vessels, 2023, 38 : 1305 - 1317
  • [44] The estimation of coronary artery calcium thickness by computed tomography angiography based on optical coherence tomography measurements
    Okutsu, Masaaki
    Mitomo, Satoru
    Onishi, Hirokazu
    Nakajima, Akihiro
    Yabushita, Hiroto
    Matsuoka, Satoshi
    Kawamoto, Hiroyoshi
    Watanabe, Yusuke
    Tanaka, Kentaro
    Naganuma, Toru
    Tahara, Satoko
    Nakamura, Shotaro
    Basavarajaiah, Sandeep
    Nakamura, Sunao
    HEART AND VESSELS, 2023, 38 (11) : 1305 - 1317
  • [45] Measurements of KVp and HVL for CT scanners
    So, J
    Nickoloff, EL
    Lu, ZF
    Dutta, AK
    MEDICAL PHYSICS, 2003, 30 (06) : 1353 - 1353
  • [46] It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimization
    Brenner, DJ
    McCollough, CH
    Orton, CG
    MEDICAL PHYSICS, 2006, 33 (05) : 1189 - 1191
  • [47] Estimation of stature and sex from sacrum and coccyx measurements by multidetector computed tomography in Chinese
    Zhan, Meng-jun
    Fan, Fei
    Qiu, Li-rong
    Peng, Zhao
    Zhang, Kui
    Deng, Zhen-hua
    LEGAL MEDICINE, 2018, 34 : 21 - 26
  • [48] Estimation of sex from computed tomography images of skull measurements in an adult Turkish population
    Meral, Orhan
    Meydan, Reyhan
    Toklu, Belkis Betul
    Kaya, Ahsen
    Karadayi, Beytullah
    Acar, Turker
    ACTA RADIOLOGICA, 2022, 63 (11) : 1513 - 1521
  • [49] Estimation of normal computed tomography measurements for the upper cervical spine in the pediatric age group
    Vachhrajani, Shobhan
    Sen, Anish N.
    Satyan, Krishna
    Kulkarni, Abhaya V.
    Birchansky, Sherri B.
    Jea, Andrew
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2014, 14 (04) : 425 - 433
  • [50] Estimation of Hemi-Abdominal-Based Free Flap Weight Using Two Computed Tomography-Derived Measurements
    Greige, Nicolas
    Liu, Bryce
    Nash, David
    Weichman, Katie E.
    Ricci, Joseph A.
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2022, 38 (07) : 549 - 554