Purpose: To determine the HVL of CT systems from CTDI dosimetry measurements without additional test, and to overcome the technical difficulties in CT HVL measurements. Method and Materials: The HVL of one multi‐detector CT scanner was measured when the scanner is static, over the available energy range (80∼140 kVp) and with different bow‐tie filter configurations. Commercial CT dose phantoms in compliance with FDA specifications were used to measure the exposures. Nine doses at the central, peripheral, and intermediate positions were measured for both head and body phantoms. Averages were taken for doses measured at axially symmetric positions of each phantom. These averages were compared to the central position dose measurements. The ratios were analyzed along with the HVL values measured under exactly the same conditions and fitted to second power polynomials. Combining the fitting parameters and dosimetry measurements from different machines, the corresponding HVL were predicted and compared to the measured value of each machine. Results: The HVL of the CT scanner were determined to be between 5 to 10 mm Al over the energy range assessed. When the values were plotted against the dose at the peripheral or intermediate position, normalized by center dose, the curves all fit to second power polynomials with R2>0.99. When applying the correlation obtained from the fittings to dosimetry measurements from different machines, the calculated HVLs are within 5% or 0.5 mm Al error of the measured values. Conclusion: This study showed that the data collected for the CTDI measurements can be directly used to estimate the HVL of CT scanners to certain accuracy. This will reduce the time and effort needed for medical physicists to determine the HVL of CT systems during acceptance testing and annual quality assurance surveys. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2340 / 2340
页数:1
相关论文
共 50 条
  • [1] Estimation of Computed Tomography Dose Index (CTDI) Using Monte Carlo Simulation
    Talbi, Mohammed
    Aabid, Mohammed
    El Mansouri, M'hamed
    Nhila, Oussama
    Semghouli, Slimane
    Sebihi, Rajaa
    Choukri, Abdelmajid
    Khalis, Mohammed
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S103 - S109
  • [2] Estimation of Computed Tomography Dose Index (CTDI) Using Monte Carlo Simulation
    Mohammed Talbi
    Mohammed Aabid
    M’hamed El Mansouri
    Oussama Nhila
    Slimane Semghouli
    Rajaa Sebihi
    Abdelmajid Choukri
    Mohammed Khalis
    Moscow University Physics Bulletin, 2021, 76 : S103 - S109
  • [3] Application of a Tandem system for HVL evaluation in Computed Tomography
    Fontes, Ladyjane Pereira
    Correa, Eduardo Lima
    Potiens, Maria da Penha A.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 62 - 64
  • [4] Monte Carlo Simulation of the Computed Tomography Dose Index (CTDI) Using GATE
    Mkimel, M.
    El Baydaoui, R.
    Mesradi, M. R.
    Tahiri, Z.
    Talasmat, K.
    Halimi, A.
    Krim, M.
    Saad, E.
    Hilali, A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2020, 17 (06) : 900 - 907
  • [5] Monte Carlo Simulation of the Computed Tomography Dose Index (CTDI) Using GATE
    M. Mkimel
    R. El Baydaoui
    M. R. Mesradi
    Z. Tahiri
    K. Talasmat
    A. Halimi
    M. Krim
    E. Saad
    A. Hilali
    Physics of Particles and Nuclei Letters, 2020, 17 : 900 - 907
  • [6] Sex Estimation From Sternal Measurements Using Multidetector Computed Tomography
    Ekizoglu, Oguzhan
    Hocaoglu, Elif
    Inci, Ercan
    Bilgili, Mustafa Gokhan
    Solmaz, Dilek
    Erdil, Irem
    Can, Ismail Ozgur
    MEDICINE, 2014, 93 (27)
  • [7] Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology
    Ruan, Chun
    Yukihara, Eduardo G.
    Clouse, William J.
    Gasparian, Patricia B. R.
    Ahmad, Salahuddin
    MEDICAL PHYSICS, 2010, 37 (07) : 3560 - 3568
  • [8] Stature estimation using scapula measurements by postmortem computed tomography in the southern Thai population
    Monum, Tawachai
    Opaburanakul, Thutchai
    Samai, Wirachai
    Kosawiwat, Komet
    Kawin, Chanathip
    EGYPTIAN JOURNAL OF FORENSIC SCIENCES, 2024, 14 (01)
  • [9] Body mass estimation in modern population using anthropometric measurements from computed tomography
    Lorkiewicz-Muszynska, Dorota
    Przystanska, Agnieszka
    Kociemba, Wojciech
    Sroka, Alicja
    Rewekant, Artur
    Zaba, Czeslaw
    Paprzycki, Wlodzimierz
    FORENSIC SCIENCE INTERNATIONAL, 2013, 231 (1-3) : 405.e1 - 405.e6
  • [10] Stature estimation in Japanese cadavers based on scapular measurements using multidetector computed tomography
    Torimitsu, Suguru
    Makino, Yohsuke
    Saitoh, Hisako
    Sakuma, Ayaka
    Ishii, Namiko
    Hayakawa, Mutsumi
    Inokuchi, Go
    Motomura, Ayumi
    Chiba, Fumiko
    Hoshioka, Yumi
    Iwase, Hirotaro
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2015, 129 (01) : 211 - 218