Can we predict which patients with implantable cardioverter defibrillators receive appropriate shock therapy? A study of 155 patients

被引:9
|
作者
Rinaldi, CA [1 ]
Simon, RDB [1 ]
Baszko, A [1 ]
Bostock, J [1 ]
Elliot, D [1 ]
Bucknall, C [1 ]
Gill, JS [1 ]
机构
[1] Guys & St Thomas Hosp, Ctr Cardiothorac, London SE1 7EH, England
关键词
implantable cardioverter defibrillators; shock therapy;
D O I
10.1016/S0167-5273(02)00364-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Appropriate shock therapy (AST) occurs in the minority of patients with implantable cardioverter defibrillators (ICDs). We assessed which patients received AST and whether there were any predictive factors. Methods: We retrospectively analysed data from 155 patients implanted with ICDs at our institution from a period from February 1984 to February 2001. Stored electrogram data were analysed. We sub-divided patients on the basis of underlying cardiac disease. Various clinical echocardiographic and electrophysiological variables were studied. Results: AST occurred in 53 (34%) of patients (Group 1) and no AST in 102 (64%) of patients (Group 2). Impaired LV function was significantly associated with AST. Group I patients had a lower ejection fraction (EF) compared to Group 2 (37.5+/-13% vs. 47.8+/-14%, P<0.0001). Seventy-two percent of patients with AST had an EF <40% vs. 35% of patients in Group 2 (P<0.0001). NYHA Class was also associated with AST, 42% of Group 1 were in NYHA Class III/IV vs. 12% in Group 2 (P<0.001). Programmed electrical stimulation (PES) was a predictor of AST. PES was positive in a greater proportion of patients in Group I vs. 2 (88% vs. 64%, P<0.0006). Sub-group analysis showed that patients with dilated cardiomyopathy (DCM) had a high incidence of AST (80%). In these patients PES was a poor predictor of AST being positive in only 25%. Conclusion: AST occurs in the minority of our patients. Certain pre-procedural variables predict AST. PES does not appear useful in predicting shock therapy in DCM patients and a negative PES should not preclude ICD implantation in this group. (C) 2002 Published by Elsevier Science Ireland Ltd.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [41] Appropriate and inappropriate shocks in hypertrophic cardiomyopathy patients with subcutaneous implantable cardioverter-defibrillators: An international multicenter study
    Nazer, Babak
    Dale, Zack
    Carrassa, Gianmarco
    Reza, Nosheen
    Ustunkaya, Tuna
    Papoutsidakis, Nikolaos
    Gray, Andrew
    Howell, Stacey J.
    Elman, Miriam R.
    Pieragnoli, Paolo
    Ricciardi, Giuseppe
    Jacoby, Daniel
    Frankel, David S.
    Owens, Anjali
    Olivotto, Iacopo
    Heitner, Stephen B.
    HEART RHYTHM, 2020, 17 (07) : 1107 - 1114
  • [42] Myocardial fibrosis predicts appropriate device therapy in patients with implantable cardioverter defibrillators for primary prevention of sudden cardiac death
    Iles, L.
    Pfluger, H.
    Lefkovits, L.
    Butler, M. J.
    Kistler, P. M.
    Kaye, D. M.
    Taylor, A. J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 283 - 283
  • [43] Patients' Attitudes and Perceptions of Implantable Cardioverter-Defibrillators: Potential Barriers to Appropriate Primary Prophylaxis
    Yuhas, Jennifer
    Mattocks, Kristin
    Gravelin, Laura
    Remetz, Michael
    Foley, John
    Fazio, Richard
    Lampert, Rachel
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (10): : 1179 - 1187
  • [44] Mortality after implantable cardioverter defibrillators in dialysis patients: a nationwide study
    Alhakak, A.
    Ostergaard, L.
    Butt, J. H.
    Vinther, M.
    Philbert, B. T.
    Jacobsen, P. K.
    Petersen, J. K.
    Gislason, G. H.
    Torp-Pedersen, C.
    Kober, L.
    Fosbol, E.
    Mogensen, U. M.
    Weeke, P. E.
    EUROPEAN HEART JOURNAL, 2020, 41 : 791 - 791
  • [45] Effect of concomitant antiarrhythmic therapy on survival in patients with implantable cardioverter-defibrillators
    Ho, AT
    Pai, S
    Timothy, P
    Pai, RG
    CIRCULATION, 2002, 106 (19) : 408 - 408
  • [46] Digoxin Is Associated With Increased Shock Events and Electrical Storms in Patients With Implantable Cardioverter Defibrillators
    Mina, George S.
    Acharya, Madan
    Shepherd, Taylor
    Gobrial, George
    Tekeste, Michael
    Watti, Hussam
    Bhandari, Ruchi
    Saini, Aditya
    Reddy, Pratap
    Dominic, Paari
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY AND THERAPEUTICS, 2018, 23 (02) : 142 - 148
  • [47] Nutritional Status Is Associated with Mortality but Not Appropriate Discharge of Implantable Cardioverter Defibrillators in Patients with Heart Failure
    Yakut, Idris
    Kanal, Yuecel
    Aksoy, Atik
    Ozeke, Ozcan
    Ozcan, Ozgur Ulas
    Ozen, Yasin
    Aras, Dursun
    DIAGNOSTICS, 2025, 15 (05)
  • [48] Appropriate and Inappropriate Implantable Cardioverter Defibrillators Therapies in Arrhythmogenic Right Ventricular Cardiomyopathy/Dysplasia Patients
    Al-Ghamdi, Bandar
    Mallawi, Yaseen
    Shafquat, Azam
    AlRuwaili, Nadiah
    Alhazaymeh, Ayman
    Al-Manea, Waleed
    Al-Fayyadh, Majid
    CARDIOLOGY RESEARCH, 2018, 9 (04) : 204 - 214
  • [49] Impact of Moderate to Severe Renal Impairment on Mortality and Appropriate Shocks in Patients with Implantable Cardioverter Defibrillators
    Alla, Venkata M.
    Anand, Kishlay
    Hundal, Mandeep
    Chen, Aimin
    Karnam, Showri
    Hee, Tom
    Hunter, Claire
    Mooss, Aryan N.
    Esterbrooks, Dennis
    Mohiuddin, Syed M.
    CARDIOLOGY RESEARCH AND PRACTICE, 2010, 2010
  • [50] PREDICTORS OF INAPPROPRIATE THERAPY IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AND CHAGAS' CARDIOMYOPATHY
    Miranda, R. I.
    Femenia, F.
    Lopez, J.
    Serra, J.
    Muratore, C.
    Valentino, M.
    Retyk, E.
    Galizio, N.
    Rodriguez, C.
    Baranchuk, A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S260 - S261