Can we predict which patients with implantable cardioverter defibrillators receive appropriate shock therapy? A study of 155 patients

被引:9
|
作者
Rinaldi, CA [1 ]
Simon, RDB [1 ]
Baszko, A [1 ]
Bostock, J [1 ]
Elliot, D [1 ]
Bucknall, C [1 ]
Gill, JS [1 ]
机构
[1] Guys & St Thomas Hosp, Ctr Cardiothorac, London SE1 7EH, England
关键词
implantable cardioverter defibrillators; shock therapy;
D O I
10.1016/S0167-5273(02)00364-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Appropriate shock therapy (AST) occurs in the minority of patients with implantable cardioverter defibrillators (ICDs). We assessed which patients received AST and whether there were any predictive factors. Methods: We retrospectively analysed data from 155 patients implanted with ICDs at our institution from a period from February 1984 to February 2001. Stored electrogram data were analysed. We sub-divided patients on the basis of underlying cardiac disease. Various clinical echocardiographic and electrophysiological variables were studied. Results: AST occurred in 53 (34%) of patients (Group 1) and no AST in 102 (64%) of patients (Group 2). Impaired LV function was significantly associated with AST. Group I patients had a lower ejection fraction (EF) compared to Group 2 (37.5+/-13% vs. 47.8+/-14%, P<0.0001). Seventy-two percent of patients with AST had an EF <40% vs. 35% of patients in Group 2 (P<0.0001). NYHA Class was also associated with AST, 42% of Group 1 were in NYHA Class III/IV vs. 12% in Group 2 (P<0.001). Programmed electrical stimulation (PES) was a predictor of AST. PES was positive in a greater proportion of patients in Group I vs. 2 (88% vs. 64%, P<0.0006). Sub-group analysis showed that patients with dilated cardiomyopathy (DCM) had a high incidence of AST (80%). In these patients PES was a poor predictor of AST being positive in only 25%. Conclusion: AST occurs in the minority of our patients. Certain pre-procedural variables predict AST. PES does not appear useful in predicting shock therapy in DCM patients and a negative PES should not preclude ICD implantation in this group. (C) 2002 Published by Elsevier Science Ireland Ltd.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [21] Appropriate and inappropriate therapy in patients with single- or multi-chamber implantable cardioverter-defibrillators
    Burger, Achim Leo
    Schmidinger, Herwig
    Ristl, Robin
    Pezawas, Thomas
    HELLENIC JOURNAL OF CARDIOLOGY, 2020, 61 (06) : 421 - 427
  • [22] The effect of gender on mortality or appropriate shock in patients with nonischemic cardiomyopathy who have implantable cardioverter-defibrillators
    Chen, Henry A.
    Hsia, Henry H.
    Vagelos, Randall
    Fowler, Michael
    Wang, Paul
    Al-Ahmad, Amin
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (03): : 390 - 394
  • [23] Which Patients With Cardiac Sarcoidosis Should Receive Implantable Cardioverter-Defibrillators Some Answers but Many Questions Remain
    Birnie, David
    Ha, Andrew
    Kron, Jordana
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (08):
  • [24] Electrical Storm in Patients with Implantable Cardioverter-Defibrillators Can It Be Forecast?
    Emkanjoo, Zahra
    Alihasani, Narges
    Alizadeh, Abolfath
    Tayyebi, Mohammad
    Bonakdar, Hamid
    Barakpour, Hamid
    Sadr-Ameli, Mohammad Ali
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (06) : 563 - 567
  • [25] Very low rate of appropriate shock therapy in primary prevention patients who receive an implantable cardioverter defibrillator in a real world setting
    Sabbag, A.
    Beinart, R.
    Suleiman, M.
    Goldenberg, I.
    Glikson, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 763 - 763
  • [26] A clinical risk score to predict the time to first appropriate device therapy in recipients of implantable cardioverter defibrillators
    Hreybe, Haitham
    Saba, Samir
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (03): : 385 - 389
  • [27] Prevalence of Appropriate Cardioverter-Defibrillator Shocks in 1038 Consecutive Patients With Implantable Cardioverter-Defibrillators
    Kruger, Adam
    Aronow, Wilbert S.
    Lai, Hoang
    Desai, Harit
    Singla, Atul
    Frishman, William H.
    Cohen, Martin
    Sorbera, Carmine
    AMERICAN JOURNAL OF THERAPEUTICS, 2009, 16 (04) : 323 - 325
  • [28] Reimplantation surgery in patients with implantable cardioverter defibrillators: A qualitative study
    Jakub, Karen E.
    Sandelowski, Margarete
    HEART & LUNG, 2016, 45 (01): : 48 - 55
  • [29] Mortality, Appropriate and Inappropriate Shock in Patients with Ischemic Heart Disease and Implantable Cardioverter-Defibrillators for Primary Prevention: A Nationwide Cohort Study
    Weeke, Peter
    Johansen, Jens B.
    Jorgensen, Ole D.
    Nielsen, Jens C.
    Moller, Mogens
    Videbaek, Regitze
    Hojgaard, Michael V.
    Riahi, Sam
    Jacobsen, Peter K.
    CIRCULATION, 2012, 126 (21)
  • [30] Changes and predictive value of dispersion of repolarization parameters for appropriate therapy in patients with biventricular implantable cardioverter-defibrillators
    Lellouche, Nicolas
    De Diego, Carlos
    Akopyan, Gina
    Boyle, Noel G.
    Mahajan, Aman
    Cesario, David A.
    Wiener, Isaac
    Shivkumar, Kalyanam
    HEART RHYTHM, 2007, 4 (10) : 1274 - 1283