IMRT optimization including random and systematic geometric errors based on the expectation of TCP and NTCP

被引:64
|
作者
Witte, Marnix G.
van der Geer, Joris
Schneider, Christoph [1 ]
Lebesque, Jocis V.
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Univ Tubingen, Univ Klin radiol, Sekt Biomed Phys, D-72074 Tubingen, Germany
关键词
radiation therapy; treatment planning; setup errors; inverse planning;
D O I
10.1118/1.2760027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was the development of a probabilistic planning method with biological cost functions that does not require the definition of margins. Geometrical uncertainties were integrated in tumor control probability (TCP) and normal tissue complication probability (NTCP) 14 objective functions for inverse planning. For efficiency reasons random errors were included by blurring the dose distribution and systematic errors by shifting structures with respect to the dose. Treatment plans were made for 19 prostate patients following four inverse strategies: Conformal with homogeneous dose to the planning target volume (PTV), a simultaneous integrated boost using a second PTV, optimization using TCP and NTCP functions together with a PTV, and probabilistic TCP and NTCP optimization for the clinical target volume without PTV. The resulting plans were evaluated by independent Monte Carlo simulation of many possible treatment histories including geometrical uncertainties. The results showed that the probabilistic optimization technique reduced the rectal wall volume receiving high dose, while at the same time increasing the dose to the clinical target volume. Without sacrificing the expected local control rate, the expected rectum toxicity could be reduced by 50% relative to the boost technique. The improvement over the conformal technique was larger yet. The margin based biological technique led to toxicity in between the boost and probabilistic techniques, but its control rates were very variable and relatively low. During evaluations, the sensitivity of the local control probability to variations in biological parameters appeared similar for all four strategies. The sensitivity to variations of the geometrical error distributions was strongest for the probabilistic technique. It is concluded that probabilistic optimization based on tumor control probability and normal tissue complication probability is feasible. It results in robust prostate treatment plans with an improved balance between local control and rectum toxicity, compared to conventional techniques. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3544 / 3555
页数:12
相关论文
共 36 条
  • [31] The Role of Random Walk-Based Techniques in Enhancing Metaheuristic Optimization Algorithms-A Systematic and Comprehensive Review
    Nassef, Ahmed M.
    Abdelkareem, Mohammad Ali
    Maghrabie, Hussein M.
    Baroutaji, Ahmad
    IEEE ACCESS, 2024, 12 : 139573 - 139608
  • [32] Monte Carlo evaluation of systematic dosimetric inaccuracies for recurrent nasopharynx carcinomas treated with fluence-based IMRT and replanned with rotating aperture optimization
    Wu, J.
    Bergman, A.
    Vellani, R.
    Welsh, M.
    Millette, M. P.
    Otto, K.
    Vollans, E.
    Popescu, I. A.
    EJC SUPPLEMENTS, 2007, 5 (04): : 337 - 337
  • [33] Position-dependent geometric errors measurement and identification for rotary axis of multi-axis machine tools based on optimization method using double ball bar
    Weichao Peng
    Hongjian Xia
    Xindu Chen
    Zeqin Lin
    Zhifeng Wang
    Haiyan Li
    The International Journal of Advanced Manufacturing Technology, 2018, 99 : 2295 - 2307
  • [34] Position-dependent geometric errors measurement and identification for rotary axis of multi-axis machine tools based on optimization method using double ball bar
    Peng, Weichao
    Xia, Hongjian
    Chen, Xindu
    Lin, Zeqin
    Wang, Zhifeng
    Li, Haiyan
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2018, 99 (9-12): : 2295 - 2307
  • [35] Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning
    de Boer, HCJ
    De Koste, JRV
    Senan, S
    Visser, AG
    Heijmen, BJM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 857 - 868
  • [36] EVALUATION OF 3 1ST-GENERATION ION-SELECTIVE ELECTRODE ANALYZERS FOR LITHIUM - SYSTEMATIC-ERRORS, FREQUENCY OF RANDOM INTERFERENCES, AND RECOMMENDATIONS BASED ON COMPARISON WITH FLAME ATOMIC EMISSION-SPECTROMETRY
    OKORODUDU, AO
    BURNETT, RW
    MCCOMB, RB
    BOWERS, GN
    CLINICAL CHEMISTRY, 1990, 36 (01) : 104 - 110