IMRT optimization including random and systematic geometric errors based on the expectation of TCP and NTCP

被引:64
|
作者
Witte, Marnix G.
van der Geer, Joris
Schneider, Christoph [1 ]
Lebesque, Jocis V.
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Univ Tubingen, Univ Klin radiol, Sekt Biomed Phys, D-72074 Tubingen, Germany
关键词
radiation therapy; treatment planning; setup errors; inverse planning;
D O I
10.1118/1.2760027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was the development of a probabilistic planning method with biological cost functions that does not require the definition of margins. Geometrical uncertainties were integrated in tumor control probability (TCP) and normal tissue complication probability (NTCP) 14 objective functions for inverse planning. For efficiency reasons random errors were included by blurring the dose distribution and systematic errors by shifting structures with respect to the dose. Treatment plans were made for 19 prostate patients following four inverse strategies: Conformal with homogeneous dose to the planning target volume (PTV), a simultaneous integrated boost using a second PTV, optimization using TCP and NTCP functions together with a PTV, and probabilistic TCP and NTCP optimization for the clinical target volume without PTV. The resulting plans were evaluated by independent Monte Carlo simulation of many possible treatment histories including geometrical uncertainties. The results showed that the probabilistic optimization technique reduced the rectal wall volume receiving high dose, while at the same time increasing the dose to the clinical target volume. Without sacrificing the expected local control rate, the expected rectum toxicity could be reduced by 50% relative to the boost technique. The improvement over the conformal technique was larger yet. The margin based biological technique led to toxicity in between the boost and probabilistic techniques, but its control rates were very variable and relatively low. During evaluations, the sensitivity of the local control probability to variations in biological parameters appeared similar for all four strategies. The sensitivity to variations of the geometrical error distributions was strongest for the probabilistic technique. It is concluded that probabilistic optimization based on tumor control probability and normal tissue complication probability is feasible. It results in robust prostate treatment plans with an improved balance between local control and rectum toxicity, compared to conventional techniques. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3544 / 3555
页数:12
相关论文
共 36 条
  • [21] A novel identification method for all geometric errors of rotary axis based on boundaryless constraint optimization method
    Peng, Weichao
    Huang, Jianfeng
    Wan, Kai
    Xia, Hongjian
    MEASUREMENT, 2024, 234
  • [22] Evaluation of dose prediction errors and optimization convergence errors of deliverable-based head-and-neck IMRT plans computed with a superposition/convolution dose algorithm
    Mihaylov, I. B.
    Siebers, J. V.
    MEDICAL PHYSICS, 2008, 35 (08) : 3722 - 3727
  • [23] A fuzzy random multiobjective 0-1 programming based on the expectation optimization model using possibility and necessity measures
    Katagiri, H
    Sakawa, M
    Kato, K
    Nishizaki, I
    MATHEMATICAL AND COMPUTER MODELLING, 2004, 40 (3-4) : 411 - 421
  • [24] Investigation of convergence and systematic dosimetric errors resulting from endorectal balloon-based heterogeneity in conformal and IMRT planning of prostate cancer
    Li, S.
    Solberg, T. D.
    Rosu, M.
    Foster, R.
    Enke, C.
    Chetty, I. J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2464 - 2464
  • [25] Systematic and random errors of PET-based 90Y 3D dose quantification
    Siman, W.
    Mawlawi, O. R.
    Mourtada, F.
    Kappadath, S. C.
    MEDICAL PHYSICS, 2020, 47 (06) : 2441 - 2449
  • [26] Quantifying and minimising systematic and random errors in X-ray micro-tomography based volume measurements
    Lin, Q.
    Neethling, S. J.
    Dobson, K. J.
    Courtois, L.
    Lee, P. D.
    COMPUTERS & GEOSCIENCES, 2015, 77 : 1 - 7
  • [27] Prediction and analysis of EDM performances considering random multiple-pulse discharges based on geometric optimization modeling
    Ni, Qin
    Zhang, Yan
    Zhou, Kebing
    Wang, Guoqian
    Ji, Lei
    Yang, Wentao
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2022, 120 (5-6): : 4123 - 4138
  • [28] Prediction and analysis of EDM performances considering random multiple-pulse discharges based on geometric optimization modeling
    Qin Ni
    Yan Zhang
    Kebing Zhou
    Guoqian Wang
    Lei Ji
    Wentao Yang
    The International Journal of Advanced Manufacturing Technology, 2022, 120 : 4123 - 4138
  • [29] A systematic matrix-based method for synthesis and optimization of Reaction/Distillation processes including Reactive Distillation
    Nezhadfard, Mahya
    Tamuzi, Amin
    Khalili-Garakani, Amirhossein
    Kasiri, Norollah
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 186 : 206 - 228
  • [30] RGG-PSO plus : Random Geometric Graphs Based Particle Swarm Optimization Method for UAV Path Planning
    Liu, Yang
    Zhu, Xiaomin
    Zhang, Xiao-Yi
    Xiao, Jiannan
    Yu, Xiaohan
    INTERNATIONAL JOURNAL OF COMPUTATIONAL INTELLIGENCE SYSTEMS, 2024, 17 (01)