IMRT optimization including random and systematic geometric errors based on the expectation of TCP and NTCP

被引:64
|
作者
Witte, Marnix G.
van der Geer, Joris
Schneider, Christoph [1 ]
Lebesque, Jocis V.
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Univ Tubingen, Univ Klin radiol, Sekt Biomed Phys, D-72074 Tubingen, Germany
关键词
radiation therapy; treatment planning; setup errors; inverse planning;
D O I
10.1118/1.2760027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was the development of a probabilistic planning method with biological cost functions that does not require the definition of margins. Geometrical uncertainties were integrated in tumor control probability (TCP) and normal tissue complication probability (NTCP) 14 objective functions for inverse planning. For efficiency reasons random errors were included by blurring the dose distribution and systematic errors by shifting structures with respect to the dose. Treatment plans were made for 19 prostate patients following four inverse strategies: Conformal with homogeneous dose to the planning target volume (PTV), a simultaneous integrated boost using a second PTV, optimization using TCP and NTCP functions together with a PTV, and probabilistic TCP and NTCP optimization for the clinical target volume without PTV. The resulting plans were evaluated by independent Monte Carlo simulation of many possible treatment histories including geometrical uncertainties. The results showed that the probabilistic optimization technique reduced the rectal wall volume receiving high dose, while at the same time increasing the dose to the clinical target volume. Without sacrificing the expected local control rate, the expected rectum toxicity could be reduced by 50% relative to the boost technique. The improvement over the conformal technique was larger yet. The margin based biological technique led to toxicity in between the boost and probabilistic techniques, but its control rates were very variable and relatively low. During evaluations, the sensitivity of the local control probability to variations in biological parameters appeared similar for all four strategies. The sensitivity to variations of the geometrical error distributions was strongest for the probabilistic technique. It is concluded that probabilistic optimization based on tumor control probability and normal tissue complication probability is feasible. It results in robust prostate treatment plans with an improved balance between local control and rectum toxicity, compared to conventional techniques. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3544 / 3555
页数:12
相关论文
共 36 条
  • [1] IMRT optimization including geometric errors based on the expectation of TCP and NTCP
    Witte, M.
    Schneider, C.
    Pos, F.
    Lebesque, J.
    van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S91 - S91
  • [2] Margin-less prostate IMRT plans, directly optimized for TCP and NTCP including geometric uncertainties
    Witte, M.
    van der Geer, J.
    Schneider, C.
    Lebesque, J.
    Alber, M.
    van Herk, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2188 - 2188
  • [3] Personalized Optimization of TCP Using NTCP Based Constraints for Ultracentral Lung Tumors
    Chen, I.
    Iyer, A.
    Thor, M.
    Wu, A.
    Apte, A.
    Rimner, A.
    Gomez, D.
    Deasy, J.
    Jackson, A.
    JOURNAL OF THORACIC ONCOLOGY, 2021, 16 (10) : S981 - S982
  • [4] Robust optimization including effects of systematic treatment errors
    Lee, E
    Bortfeld, T
    Deasy, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1978 - 1978
  • [5] The impact of random and systematic errors of MLC leaves on head-and-neck IMRT plans
    Mu, G.
    Xia, P.
    MEDICAL PHYSICS, 2006, 33 (06) : 2142 - 2142
  • [6] Sensitivity analysis of geometric parameter errors for industrial robots based on random forest
    Lv, Pin
    Shi, Weihao
    Wang, Yubin
    Li, Ruiyan
    Chen, Dongdong
    2023 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, AIM, 2023, : 1135 - 1140
  • [7] Geometric Curve Design Method of Fuzzy Reliability Based on Random Processing Errors
    Zhao, Zhi Su
    Zhang, Xing Hua
    ADVANCES IN MECHANICAL DESIGN, PTS 1 AND 2, 2011, 199-200 : 72 - +
  • [8] Implementation of Random Patient Setup Uncertainties Into Pinnacle-Based IMRT Optimization
    Moore, J.
    Gordon, J.
    Bzdusek, K.
    Siebers, J.
    MEDICAL PHYSICS, 2008, 35 (06) : 2754 - +
  • [9] A STOCHASTIC OPTIMIZATION OF THE PRODUCTION SPEED OF ROBOTS BASED ON MEASURED GEOMETRIC AND NONGEOMETRIC ERRORS
    MOON, KS
    AZADIVAR, F
    KIM, K
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 1992, 30 (01) : 49 - 62
  • [10] An interval approach based on expectation optimization for fuzzy random bilevel linear programming problems
    Ren, Aihong
    Wang, Yuping
    JOURNAL OF THE OPERATIONAL RESEARCH SOCIETY, 2015, 66 (12) : 2075 - 2085