3D sensitivity encoded ellipsoidal MR spectroscopic imaging of gliomas at 3T

被引:18
|
作者
Ozturk-Isik, Esin [1 ]
Chen, Albert. P. [1 ]
Crane, Jason C. [1 ]
Bian, Wei [1 ]
Xu, Duan [1 ]
Han, Eric T. [2 ]
Chang, Susan M. [3 ]
Vigneron, Daniel B. [1 ,4 ,5 ]
Nelson, Sarah J. [1 ,4 ,5 ]
机构
[1] Univ Calif San Francisco, Margaret Hart Surbeck Lab Adv Imaging, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] GE Healthcare, ASL W, Menlo Pk, CA 94025 USA
[3] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
[4] UCSF UCB, Joint Grad Grp Bioengn, San Francisco, CA 94158 USA
[5] Univ Calif San Francisco, Bioengn Program, San Francisco, CA 94158 USA
关键词
Glioma; 3D MR spectroscopic imaging; SENSE; Ellipsoidal sampling; Brain; MAGNETIC-RESONANCE-SPECTROSCOPY; PHASED-ARRAY COIL; BRAIN-TUMORS; SPATIAL-RESOLUTION; SENSE; RECONSTRUCTION; PROSTATE; CANCER; GRAPPA; PEPSI;
D O I
10.1016/j.mri.2009.05.028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The goal of this Study was to implement time efficient data acquisition and reconstruction methods for 3D magnetic resonance spectroscopic imaging (MRSI) of gliomas at a field strength of 3T using parallel imaging techniques. Methods: The point spread functions, signal to noise ratio (SNR), spatial resolution, metabolite intensity distributions and Cho:NAA ratio of 3D ellipsoidal, 3D sensitivity encoding (SENSE) and 3D combined ellipsoidal and SENSE (c-SENSE) k-space sampling schemes were compared with conventional k-space data acquisition methods. Results: The 3D SENSE and e-SENSE methods resulted in similar spectral patterns as the conventional MRSI methods. The Cho:NAA ratios were highly correlated (P <.05 for SENSE and P<.001 for c-SENSE) with the ellipsoidal method and all methods exhibited significantly different spectral patterns in tumor regions compared to normal appearing white matter. The geometry factors ranged between 1.2 and 1.3 for both the SENSE and c-SENSE spectra. When corrected for these factors and for differences in data acquisition times, the empirical SNRs were similar to values expected based upon theoretical grounds. The effective spatial resolution of the SENSE spectra was estimated to be same as the corresponding fully sampled k-space data, while the spectra acquired with ellipsoidal and e-SENSE 4 space samplings were estimated to have a 2.36-2.47-fold loss in spatial resolution due to the differences in their point spread functions. Conclusion: The 3D SENSE method retained the same spatial resolution as full k-space sampling but with a 4-fold reduction in scan time and an acquisition time of 9.28 min. The 3D e-SENSE method had a similar spatial resolution as the corresponding ellipsoidal sampling with a scan time of 4:36 min. Both parallel imaging methods provided clinically interpretable spectra with volumetric coverage and adequate SNR for evaluating Cho, Cr and NAA. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:1249 / 1257
页数:9
相关论文
共 50 条
  • [41] Considerations in applying compressed sensing to in vivo phosphorus MR spectroscopic imaging of human brain at 3T
    Hatay, Gokce Hale
    Yildirim, Muhammed
    Ozturk-Isik, Esin
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (08) : 1303 - 1315
  • [42] 3D TOF MR angiography to depict pituitary bright spot and to detect posterior pituitary lobe cyst: Original description at 3T MR imaging
    Meyrignac, Olivier
    Idir, Ibtir Sam
    Cognard, Christophe
    Bonneville, Jean-Francois
    Bonneville, Fabrice
    JOURNAL OF NEURORADIOLOGY, 2015, 42 (06) : 321 - 325
  • [43] MR Spectroscopic Imaging of Benign Prostatic Tissue: Findings at 3T Compared to 1.5T Initial Experience
    Chitkara, M.
    Westphalen, A.
    Kurhanewicz, J.
    Qayyum, A.
    Poder, L.
    Reed, G.
    Coakley, F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [44] Detection of prostate cancer: Utility of diffusion-weighted MR imaging and 3D MR spectroscopic imaging
    Gouhar, Ghada K.
    Taha, Tamer F.
    Allam, Mohamed N.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2010, 41 (03): : 429 - 439
  • [45] The Holy Grail in diagnostic neuroradiology: 3T or 3D?
    Frederik Barkhof
    Petra J. W. Pouwels
    Mike P. Wattjes
    European Radiology, 2011, 21 : 449 - 456
  • [46] The Holy Grail in diagnostic neuroradiology: 3T or 3D?
    Barkhof, Frederik
    Pouwels, Petra J. W.
    Wattjes, Mike P.
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 449 - 456
  • [47] T1-weighted MR imaging of glioma at 3T: a comparative study of 3D MPRAGE vs. conventional 2D spin-echo imaging
    Dodo, Toshiki
    Okada, Tomohisa
    Yamamoto, Akira
    Kanagaki, Mitsunori
    Fushimi, Yasutaka
    Okada, Tsutomu
    Sakata, Akihiko
    Arakawa, Yoshiki
    Miyamoto, Susumu
    Togashi, Kaori
    CLINICAL IMAGING, 2016, 40 (06) : 1257 - 1261
  • [48] Multiparametric 3T MR approach to the assessment of cerebral gliomas: tumor extent and malignancy
    Di Costanzo, Alfonso
    Scarabino, Tommaso
    Trojsi, Francesca
    Giannatempo, Giuseppe M.
    Popolizio, Teresa
    Catapano, Domenico
    Bonavita, Simona
    Maggialetti, Nicola
    Tosetti, Michela
    Salvolini, Ugo
    d'Angelo, Vincenzo A.
    Tedeschi, Giocchino
    NEURORADIOLOGY, 2006, 48 (09) : 622 - 631
  • [49] Multiparametric 3T MR approach to the assessment of cerebral gliomas: tumor extent and malignancy
    Alfonso Di Costanzo
    Tommaso Scarabino
    Francesca Trojsi
    Giuseppe M. Giannatempo
    Teresa Popolizio
    Domenico Catapano
    Simona Bonavita
    Nicola Maggialetti
    Michela Tosetti
    Ugo Salvolini
    Vincenzo A. d’Angelo
    Giocchino Tedeschi
    Neuroradiology, 2006, 48 : 622 - 631
  • [50] Grading of gliomas using 3D CEST imaging with compressed sensing and sensitivity encoding
    Wada, Tatsuhiro
    Togao, Osamu
    Tokunaga, Chiaki
    Oga, Masahiro
    Kikuchi, Kazufumi
    Yamashita, Koji
    Yamamoto, Hidetaka
    Yoneyama, Masami
    Kobayashi, Koji
    Kato, Toyoyuki
    Ishigami, Kousei
    Yabuuchi, Hidetake
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158