3D sensitivity encoded ellipsoidal MR spectroscopic imaging of gliomas at 3T

被引:18
|
作者
Ozturk-Isik, Esin [1 ]
Chen, Albert. P. [1 ]
Crane, Jason C. [1 ]
Bian, Wei [1 ]
Xu, Duan [1 ]
Han, Eric T. [2 ]
Chang, Susan M. [3 ]
Vigneron, Daniel B. [1 ,4 ,5 ]
Nelson, Sarah J. [1 ,4 ,5 ]
机构
[1] Univ Calif San Francisco, Margaret Hart Surbeck Lab Adv Imaging, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] GE Healthcare, ASL W, Menlo Pk, CA 94025 USA
[3] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
[4] UCSF UCB, Joint Grad Grp Bioengn, San Francisco, CA 94158 USA
[5] Univ Calif San Francisco, Bioengn Program, San Francisco, CA 94158 USA
关键词
Glioma; 3D MR spectroscopic imaging; SENSE; Ellipsoidal sampling; Brain; MAGNETIC-RESONANCE-SPECTROSCOPY; PHASED-ARRAY COIL; BRAIN-TUMORS; SPATIAL-RESOLUTION; SENSE; RECONSTRUCTION; PROSTATE; CANCER; GRAPPA; PEPSI;
D O I
10.1016/j.mri.2009.05.028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The goal of this Study was to implement time efficient data acquisition and reconstruction methods for 3D magnetic resonance spectroscopic imaging (MRSI) of gliomas at a field strength of 3T using parallel imaging techniques. Methods: The point spread functions, signal to noise ratio (SNR), spatial resolution, metabolite intensity distributions and Cho:NAA ratio of 3D ellipsoidal, 3D sensitivity encoding (SENSE) and 3D combined ellipsoidal and SENSE (c-SENSE) k-space sampling schemes were compared with conventional k-space data acquisition methods. Results: The 3D SENSE and e-SENSE methods resulted in similar spectral patterns as the conventional MRSI methods. The Cho:NAA ratios were highly correlated (P <.05 for SENSE and P<.001 for c-SENSE) with the ellipsoidal method and all methods exhibited significantly different spectral patterns in tumor regions compared to normal appearing white matter. The geometry factors ranged between 1.2 and 1.3 for both the SENSE and c-SENSE spectra. When corrected for these factors and for differences in data acquisition times, the empirical SNRs were similar to values expected based upon theoretical grounds. The effective spatial resolution of the SENSE spectra was estimated to be same as the corresponding fully sampled k-space data, while the spectra acquired with ellipsoidal and e-SENSE 4 space samplings were estimated to have a 2.36-2.47-fold loss in spatial resolution due to the differences in their point spread functions. Conclusion: The 3D SENSE method retained the same spatial resolution as full k-space sampling but with a 4-fold reduction in scan time and an acquisition time of 9.28 min. The 3D e-SENSE method had a similar spatial resolution as the corresponding ellipsoidal sampling with a scan time of 4:36 min. Both parallel imaging methods provided clinically interpretable spectra with volumetric coverage and adequate SNR for evaluating Cho, Cr and NAA. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:1249 / 1257
页数:9
相关论文
共 50 条
  • [31] Reproducibility of 3D 1H MR spectroscopic imaging of the prostate at 1.5T
    Lagemaat, Miriam W.
    Zechmann, Christian M.
    Futterer, Jurgen J.
    Weiland, Elisabeth
    Lu, Jianping
    Villeirs, Geert M.
    Holshouser, Barbara A.
    van Hecke, Paul
    Lemort, Marc
    Schlemmer, Heinz-Peter
    Barentsz, Jelle O.
    Roell, Stefan O.
    Heerschap, Arend
    Scheenen, Tom W. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (01) : 166 - 173
  • [32] MR imaging of the internal auditory canal and inner ear at 3T: Comparison between 3D driven equilibrium and 3D balanced fast field echo sequences
    Byun, Jun Soo
    Kim, Hyung-Jin
    Yim, You Jeong
    Kim, Sung Tae
    Jeon, Pyoung
    Kim, Keon Ha
    Kim, Sam Soo
    Jeon, Yong Hwan
    Lee, Jiwon
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (03) : 212 - 218
  • [33] 3D mapping of total choline in human breast cancer using high-speed MR spectroscopic imaging at 3T: initial experience during neoadjuvant therapy
    Posse, S.
    Zhang, T.
    Royce, M.
    Dayao, Z.
    Lopez, S.
    Sillerud, L.
    Casey, L.
    Eberhardt, S.
    Lomo, L.
    Rajput, A.
    Russell, J.
    Lee, S-J
    Bolan, P.
    CANCER RESEARCH, 2012, 72
  • [34] Comparison of 3D TOF-MRA and 3D CE-MRA at 3T for imaging of intracranial aneurysms
    Cirillo, Mario
    Scomazzoni, Francesco
    Cirillo, Luigi
    Cadioli, Marcello
    Simionato, Franco
    Iadanza, Antonella
    Kirchin, Miles
    Righi, Claudio
    Anzalone, Nicoletta
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : E853 - E859
  • [35] Quantitative PET imaging with the 3T MR-BrainPET
    Weirich, C.
    Scheins, J.
    Lohmann, P.
    Tellmann, L.
    Byars, L.
    Michel, C.
    Kops, E. Rota
    Brenner, D.
    Herzog, H.
    Shah, N. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 26 - 28
  • [36] 3T MR imaging protocol for characterization of renal masses
    Khatri, Gaurav
    Pedrosa, Ivan M.
    APPLIED RADIOLOGY, 2012, 41 : 22 - 26
  • [37] Considerations in applying compressed sensing to in vivo phosphorus MR spectroscopic imaging of human brain at 3T
    Gokce Hale Hatay
    Muhammed Yildirim
    Esin Ozturk-Isik
    Medical & Biological Engineering & Computing, 2017, 55 : 1303 - 1315
  • [38] Diffusion tensor MR imaging: Fiber tracking at 3T
    Lim, CCT
    Cheng, S
    Zimine, I
    Xu, M
    Sitoh, YY
    Yeo, TT
    Golay, X
    Ng, YK
    Hui, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 121 - 121
  • [39] Identification of the Nervus Intermedius Using 3T MR Imaging
    Burmeister, H. P.
    Baltzer, P. A.
    Dietzel, M.
    Krumbein, I.
    Bitter, T.
    Schrott-Fischer, A.
    Guntinas-Lichius, O.
    Kaiser, W. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (03) : 460 - 467
  • [40] Optimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3T
    Scheenen, TWJ
    Gambarota, G
    Weiland, E
    Klomp, DWJ
    Fütterer, JJ
    Barentsz, JO
    Heerschap, A
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1268 - 1274