Characterisation of vibration signals using continuous wavelet transform for condition assessment of on-load tap-changers

被引:19
|
作者
Kang, P
Birtwhistle, D
机构
[1] United Technol Res Ctr, E Hartford, CT 06108 USA
[2] Queensland Univ Technol, Brisbane, Qld Q4001, Australia
关键词
D O I
10.1006/mssp.2002.1525
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The operation of an on-load tap-changer (OLTC) on a high-voltage power transformer produces a vibration signal that consists of a series of well-defined transients. Due to the harmonic and non-stationary nature of transient. vibration signals, the traditional frequency and time-frequency techniques are not effective for characterising this type of vibration signal. The time domain features such as delays in time between transients, and the number and strengths of transients are more important for the assessment of the OLTC condition; This paper details the development of an OLTC vibration signal characterisation technique using the continuous wavelet transform (CWT). The CWT, due to its capability of multi-scale localisation in the time domain, is an effective tool in extracting the essential features from the original signals. These features are utilised to provide reliable indications of the health of the equipment. Signals from real plant are used to demonstrate the usefulness of the proposed technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:561 / 577
页数:17
相关论文
共 50 条
  • [31] Condition monitoring of power transformer on-load tap-changers. Part 2: Detection of ageing from vibration signatures
    Kang, P
    Birtwhistle, D
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (04) : 307 - 311
  • [32] Condition monitoring of power transformer on-load tap-changers. Part 1: Automatic condition diagnostics
    Kang, P
    Birtwhistle, D
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (04) : 301 - 306
  • [33] A Mechanical Fault Diagnosis of On-load Tap-changers Based on Phase Space Fusion of Bayes Estimation and CM-SVDD
    Wang F.
    Zeng Q.
    Zheng Y.
    Qian Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (01): : 358 - 368
  • [34] Condition Monitoring using Wavelet Transform and Fuzzy Logic by Vibration Signals
    Nassser, Maryam
    Mohammadi, Masoud
    LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2012, 9 (04): : 5680 - 5685
  • [35] Mechanical condition monitoring of on-load tap changers based on chaos theory and k-means clustering method
    Zhou, Xiang
    Wang, Fenghua
    Fu, Jian
    Lin, Jiayang
    Jin, Zhijian
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (06): : 1541 - 1548
  • [36] Mechanical Fault Diagnostics of Power Transformer On-Load Tap Changers Using Dynamic Time Warping
    Yang, Ruilin
    Zhang, Dandan
    Li, Zhenbiao
    Yang, Kai
    Mo, Shi
    Li, Li
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (09) : 3119 - 3127
  • [37] Optimal placement of on-load tap changers in distribution networks using SA-TLBO method
    Hosseinpour, H.
    Bastaee, B.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 64 : 1119 - 1128
  • [38] Analysis of Vibration Signal for Power Transformer On-Load Tap Changer (OLTC) Condition Monitoring
    Seo, Junhyuck
    Ma, Hui
    Saha, Tapan K.
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [39] Detection and Separation of On-Load Tap Changer Vibration Signals Based on PSO-VMD
    Shi, Yanhui
    Yang, Yang
    Ruan, Yanjun
    Yuan, Kaiwen
    Luo, Zhao
    Lu, Sizhao
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 636 - 641
  • [40] Effect of Insulation Oil on Vibration Signals of On-load Tap-changer of Power Transformer
    Wang F.
    Xie F.
    Wang W.
    Zheng Y.
    He W.
    Qian Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (10): : 3273 - 3279