Characterisation of vibration signals using continuous wavelet transform for condition assessment of on-load tap-changers

被引:19
|
作者
Kang, P
Birtwhistle, D
机构
[1] United Technol Res Ctr, E Hartford, CT 06108 USA
[2] Queensland Univ Technol, Brisbane, Qld Q4001, Australia
关键词
D O I
10.1006/mssp.2002.1525
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The operation of an on-load tap-changer (OLTC) on a high-voltage power transformer produces a vibration signal that consists of a series of well-defined transients. Due to the harmonic and non-stationary nature of transient. vibration signals, the traditional frequency and time-frequency techniques are not effective for characterising this type of vibration signal. The time domain features such as delays in time between transients, and the number and strengths of transients are more important for the assessment of the OLTC condition; This paper details the development of an OLTC vibration signal characterisation technique using the continuous wavelet transform (CWT). The CWT, due to its capability of multi-scale localisation in the time domain, is an effective tool in extracting the essential features from the original signals. These features are utilised to provide reliable indications of the health of the equipment. Signals from real plant are used to demonstrate the usefulness of the proposed technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:561 / 577
页数:17
相关论文
共 50 条
  • [21] Influence of wind and solar energy on the frequency of switching operations of On-Load Tap-Changers
    Krpal, Ondrej
    Brueckl, Oliver
    Riepl, Markus
    PROCEEDINGS OF THE 13TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2012, VOLS 1 AND 2, 2012, : 719 - 722
  • [22] Simulated Circuits for Switching Tests of On-Load Tap-Changers with a Single Auxiliary Contact
    Stannev, Stoil
    2014 18TH INTERNATIONAL SYMPOSIUM ON ELECTRICAL APPARATUS AND TECHNOLOGIES (SIELA), 2014,
  • [23] On-line Monitoring and Diagnostics For Power Transformers Application to On-load Tap-changers
    Mackenzie, E. A.
    Crossey, J.
    dePablo, A.
    Ferguson, W.
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [24] Dynamic analysis method for feature extraction of mechanical vibration signals of on-load tap changers
    Zhao, Tong
    Li, Qingmin
    Chen, Ping
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (01): : 41 - 46
  • [25] Vacuum switching technology improves the switching capacity of on-load tap-changers in HVDC applications
    Shen, Dazhong
    Kraemer, Axel
    Dohnal, Dieter
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2530 - 2535
  • [26] On switching transient modeling and analysis of electronic on-load tap-changers based Sen transformer
    Pan, Yuhang
    Han, Song
    Zhou, Chao
    Guo, Xi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 130
  • [27] CONTRIBUTIONS TO THE DEVELOPMENT OF DEVICES TO INCREASE SAFETY IN OPERATION OF THE ON-LOAD -TAP-CHANGERS OF THE POWER TRANSFORMERS
    Cujba, Tiberiu
    Cernomazu, Dorel
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2011, 73 (02): : 251 - 262
  • [28] Comparative Analysis of Acoustic Emission Signals from On-Load Tap-Changers for Potential Detecting of Non-Simultaneous Operations
    Cichon, Andrzej
    Borucki, Sebastian
    Wlodarz, Michal
    ARCHIVES OF ACOUSTICS, 2024, 49 (02) : 277 - 286
  • [29] Feature analysis methodology for phase portrait structure of mechanical vibration signals of on-load tap changers in multidimensional space
    Zhao, Tong
    Zhang, Li
    Li, Qing-Min
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (08): : 102 - 105
  • [30] Reliability Evaluation of On-load Tap-changers Based on Multi-state Multi-Valued Decision Diagram
    Tian, Huimin
    Liu, Yanhong
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 5942 - 5947