Day-to-day reproducibility of prolonged ambulatory colonic manometry in healthy subjects

被引:16
|
作者
Rao, S. S. C. [1 ]
Singh, S. [1 ]
Mudipalli, R. [1 ]
机构
[1] Univ Iowa, Dept Internal Med, Div Neurogastroenterol, Carver Coll Med, Iowa City, IA 52242 USA
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2010年 / 22卷 / 06期
关键词
ambulatory colonic manometry; intraindi-vidual and interindividual variation; reproducibility; SLOW-TRANSIT CONSTIPATION; MOTOR-ACTIVITY; 24; HOUR; MOTILITY; HUMANS; DIARRHEA; PRESSURE; PATTERNS;
D O I
10.1111/j.1365-2982.2010.01492.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Although colonic manometry provides useful information regarding colonic physiology, considerable variability has been reported both for regional motility and manometric patterns. Whether colonic manometry is reproducible is not known. Methods Seven healthy volunteers (three men, four women, mean age = 34 years) underwent two studies of 24-h ambulatory colonic manometry, each 2 weeks apart. Manometry was performed by placing a six-sensor solid-state probe, up to the hepatic flexure and anchored to colonic mucosa. Colonic motility was assessed by the number and area-under-curve (AUC) of pressure waves and motility patterns such as high-amplitude propagating contractions (HAPC). Waking and meal-induced gastrocolonic responses were also assessed. Paired t-test was used to examine the reproducibility and intra and interindividual variability. Key Results The number of pressure waves and propagating pressure waves and HAPC, and AUC were similar between the two studies. Diurnal variation, waking and meal-induced gastrocolonic responses were also reproducible. There was some variability in the incidence of individual colonic motor patterns. Conclusions & Inferences Colonic manometry findings were generally reproducible, particularly for the assessment of key physiologic changes, such as meal-induced gastrocolonic, HAPC, and waking responses.
引用
收藏
页码:640 / +
页数:8
相关论文
共 50 条
  • [41] Immediate and day-to-day reproducibility of the signal-averaged electrocardiogram in patients with coronary artery disease
    Paquay, JL
    Zimmermann, M
    Mermillod, B
    Adamec, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (04): : 443 - 454
  • [42] Can Colonic Manometry Studies Be Done on the Day of Colonic Motility Catheter Placement?
    Ammoury, Rana F.
    Emhardt, John D.
    Aitchison, William B.
    Horn, Debra S.
    Croffie, Joseph M.
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2012, 55 (03): : 278 - 282
  • [43] Influence of age and sex and day-to-day and within-day biological variation on plasma concentrations of fatty acid-binding protein and myoglobin in healthy subjects
    Pelsers, MMAL
    Chapelle, JP
    Knapen, M
    Vermeer, C
    Muijtjens, AMM
    Hermens, WT
    Glatz, JFC
    CLINICAL CHEMISTRY, 1999, 45 (03) : 441 - 443
  • [44] DAY-TO-DAY VARIATIONS IN BASAL METABOLIC RATES AND ENERGY INTAKES OF HUMAN-SUBJECTS
    SOARES, MJ
    PIERS, LS
    KRAAI, L
    SHETTY, PS
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1989, 43 (07) : 465 - 472
  • [45] Normal and abnormal day-to-day variability of urinary albumin excretion in control and diabetic subjects
    Chau, NP
    Bouhanick, B
    Mestivier, D
    Taki, M
    Marre, M
    DIABETES & METABOLISM, 2000, 26 (01) : 36 - 41
  • [46] DAY-TO-DAY VARIATION IN IRON-STATUS INDEXES IN HEALTHY-MEN AND WOMEN
    BOREL, MJ
    SMITH, SM
    DERR, J
    BEARD, JL
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1991, 54 (04): : 729 - 735
  • [47] Dynamical association between day-to-day fluctuations in inflammatory markers and affect in healthy individuals
    Schenk, H. M.
    van Ockenburg, S. L.
    Nawijn, M. C.
    de Jonge, P.
    Rosmalen, J. G.
    BRAIN BEHAVIOR AND IMMUNITY, 2016, 57 : E33 - E33
  • [48] Day-to-day reactogenicity and the healthy vaccinee effect of measles-mumps-rubella vaccination
    Virtanen, M
    Peltola, H
    Paunio, M
    Heinonen, OP
    PEDIATRICS, 2000, 106 (05) : art. no. - e62
  • [49] PROLONGED AMBULATORY DUODENOJEJUNAL MANOMETRY (DJM) - NORMAL VALUES IN HEALTHY HUMANS
    THONGSAWAT, S
    ELLERBROEK, S
    SOFFER, EE
    GASTROENTEROLOGY, 1995, 108 (04) : A699 - A699
  • [50] SIDE-TO-SIDE DIFFERENCES AND DAY-TO-DAY VARIATIONS OF TRANSCRANIAL DOPPLER PARAMETERS IN NORMAL SUBJECTS
    SORTEBERG, W
    LANGMOEN, A
    LINDEGAARD, KF
    NORNES, H
    JOURNAL OF ULTRASOUND IN MEDICINE, 1990, 9 (07) : 403 - 409